Declaration of Interest Forms (SBD4)

Request For A Quote

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF MAINTENANCE CONSUMABLE 1. TESYS D LC1D 55KW CONTACTOR 3P 3 2. MOTOR PROTECTION C/B 4KW 10 3. SIZE 5 METAL GLAND WITH SHROUD 10 4. SIZE 4 METAL GLAND WITH SHROUD 10 5. SIZE 3 METAL GLAND WITH SHROUD 10 6. CABLE LUGS 70.0 X 10MM 100 7. ELECTRICAL CLEANER F0128 (5LTR) 10 8. DISC FLAP SANDFLEX 115X22 A240 30 9. PVC TRUNKING 16×25MM 10 10. 8 PIN REGULATED POWER SUPPLIES 230VAC 10 11. COMPRESSION CLAMP. ½” 20 12. SMART CENTURION GATE MOTOR D10 3 13. 20MM HOSPITAL SADDLES GALVE

RFQ – REQUEST FOR QUOTATION TO CARRY OUT FILTER REPLENISHMENT PROJECT ON PUDIMOE MODULE 1 SANDFILTERS AS PER THE FOLLOWING SPECIFICATIONS: - SCOPE OF WORK: REPLACE MEDIA AS PER ATTACHED SPECIFICATIONS: LAYER MEDIA SIZE DEPTH 1ST LAYER FILTERING MEDIA 0.6 MM – 1.2 MM 700 MM 2ND LAYER COARSE MEDIA 2.36 MM – 4.75 MM 150 MM 3RD LAYER PEBBLE (GRAVEL MEDIA) 6 MM – 13 MM 150 MM. • REMOVE OLD FILTER SAND AND CLEAN THE FILTER; • CLEAN THE FALSE FLOOR; • REPLACE ALL THE BROKEN/DEFECTIVE FILTER NOZZELS; THE SERVICE PROVIDER TO COMMISSION THE SAND FILTERS, FOLLOWED BY THE HANDOVER OF THE PROJECT UPON COMPLETION. MANDATORY REQUIREMENTS: 1. CIDB GRADE 2CE 2. QUALIFICATION OF PERSONNEL: B-TECH CIVIL ENGINEER OR HIGHER, AND REGISTERED WITHECSA 3. EXPERIENCE OF PERSONNEL: MUST HAVE MINIMUM 3 YEARS’ EXPERIENCE IN SANDFILTERS REFURBISHMENT PROCESS/ KNOWLEDGE OF FILTER OPERATION PRINCIPLE AND MEDIA GRADING/ APPLICATION OF LOCKOUT PROCEDURE.

RFQ – REQUEST FOR QUOTATION FOR NETWORK MONITORING TOOL FOR 36 MONTHS SPECIFICATIONS: 100-NODE ENTERPRISE LICENSE TICKET SUPPORT AND MAINTENANCE PLAN: • INSTALLATION OF THE SERVER • ON-BOARDING OF MAIN HOST TO THE SOLUTION • CONFIGURATION TO MONITOR SYSTEM HEALTH, PERFORMANCE, AND AVAILABILITY IN REAL-TIME FOR SERVERS, NETWORK DEVICES, APPLICATIONS, SERVICES, VIRTUALIZATION, CLOUD INFRASTRUCTURE AND STORAGE SYSTEMS. SCOPE THE SOLUTION MUST SUPPORT MONITORING OF: • SERVERS (WINDOWS) • NETWORK DEVICES (ROUTERS, SWITCHES AND FIREWALL) • APPLICATIONS (WEB SERVERS, DATABASES AND EMAIL SERVERS) • SERVICES SUCH AS HTTP, FTP, SSH, DNS, SNMP • VIRTUALIZATION (VMWARE AND HYPER-V) • CLOUD INFRASTRUCTURE • STORAGE SYSTEMS CORE FEATURES MUST INCLUDE: • HOST AND SERVICE MONITORING WITH CUSTOMIZABLE CHECKS • ALERTING VIA EMAIL, SMS OR INTEGRATIONS • WEB-BASED DASHBOARD FOR VISUALIZATION AND REPORTING • PLUGIN ARCHITECTURE FOR EXTENSIBILITY • PERFORMANCE GRAPHING AND HISTORICAL DATA RETENTION ALERTING AND NOTIFICATION MUST INCLUDE: • SLA REPORTS • AVAILABILITY AND UPTIME STATISTICS • CUSTOMIZABLE DASHBOARDS AND VIEWS SECURITY MUST BE CONFIGURED TO INCLUDE: • ROLE-BASED ACCESS CONTROL • ENCRYPTED COMMUNICATION • AUDIT LOGGING

RFQ – REQUEST FOR QUOTATION TO INVITE PROFESSIONAL SERVICE PROVIDERS TO SUBMIT PROPOSALS TO SUPPLY AND INSTALLATION OF NEAR OR REAL TIME WATER TELEMETRY SYSTEM AND DATA TRANSMISSION SYSTEM (4IR TECHNOLOGY) FOR PORTABLE WATER AT PUDIMOE RESERVOIR AND BOGOSING RESERVOIR. REQUIREMENTS: - THE TECHNOLOGY THAT WILL ASSIST IN MONITORING AND REPORTING OF THE FOLLOWING NOT LIMITED PARAMETERS IN REAL TIME. 1. WATER VOLUME 2. RESERVOIRS’ WATER LEVELS 3. LEAKAGE DETECTION 4. APPARENT WATER LOSES MONITORING AND REPORTING 5. WATER FLOWRATE MONITORING AND REPORTING 6. PRESSURE MONITORING AND REPORTING REPORTING AND ACCESSIBILITY 1. THE SYSTEM MUST BE ACCESSIBLE THROUGH MOBILE DEVICE, COMPUTER

RFQ – REQUEST FOR QUOTATION FOR REGION WEST - ANNUAL METER VERIFICATION MECHANICAL METERS X 661 ELECTRONIC FLOW METERS X 33 SUBMIT THE METER VERIFICATION CERTIFICATES MANDATORY: METEOROLOGIST QUALIFICATION AND SANAS ACCREDITATION

RFQ – REQUEST FOR QUOTATION FOR TRANSMITTER MX 2034 DPS,PROXIMITY 4-20MA TRANSMITTER MODEL:MX2034-01-01-09-00-01-007-00 S/N 131025

RFQ – REQUEST FOR QUOTATION FOR A MINI EXCAVATOR NET POWER -2400RPM/15.7KW ENGINE POWER C1.1 BORE 77MM STROKE 81MM

RFQ – REQUEST FOR QUOTATION TO REPLACE TWO (2)INLET ALTITUDE CONTROL VALVES(PRV) DN 300 WW-700-SIGMA-EN-12"-750-80-M6-55-Y-C-EB-2DC-PB-V-06 PRESSURE RATING:PN16 MAIN VALVE SPECIFICATION BERMAD VALVE PATTERNS: "Y" (GLOBE) SIZE RANGE: EN SERIES: 1½-16"; 40-400 MM ES SERIES: 2½-24"; 65-600 MM PRESSURE RATING: 25 BAR; 400 PSI END CONNECTIONS: FLANGED (ALL STANDARD) PLUG TYPES: FLAT DISC, V-PORT, CAVITATION CAGE TEMPERATURE RATING: 60°C; 140°F FOR COLD WATER APPLICATIONS ABSTACLE FREE FLOW PASS V-PORT THROTTLING PLUG RECOMMISSION THE PRVS AND SET RESERVOIR LEVELS ALL WORK TO BE DONE ON SITE GOOD KNOWLEDGE WORKING WITH VALVE AND PRVS OF SIMILAR EXPERIENCE (ATTACH/PROVIDE ATLEAST 2 PROOF OF PREVIOUS WORK) NB: SAFETY PROCEDURES MUST BE ADHERED AS PER MAGALIES WATER STANDARDS. : SERVICE PROVIDER MUST HAVE EXPERIENCE IN PRV'S : BIDDER MUST PROVIDE AT LEAST TWO(2) RELEVANT PO WITH INVOICE OR COMPLETION LETTERS DISPLACEMENT 1.1L GROSS POWER 16.1KW

RFQ – REQUEST FOR QUOTATION TO REPLACEMENT OF 450DN PIPELINE SECTION-LAPA TRIE TO PADDA JUNCTION SUPPLY AND DELIVER 450MM HDPE PIPES X 30 PIPE SPECIFICATION: PIPE SIZE: 450 MM PE 100 PN25 MATERIAL:HDPE PIPE SDR7.4 P/E EACH PIPE LENGHTH : 12 METERS QUANTITY: 30 WALL SIZE(PIPE THICKNESS)

RFQ – REQUEST FOR QUOTATION TO SUPPLY AND DELIVER SIX (6) TRASH PUMP & ACCESSORIES 1. X6 TRASH PUMP SPECIFICATION: HONDA GX270 OHV PETROL ENGINE SELF-PRIMING ALUMINUM PUMP WITH 2500RPM INLET AND OUTLE DIAMETER 80MM AND 5.9KW ENGINE WT30K4D MAX.DISCHARGE CAPACITY 670 / 1100 L/MIN 4-STROKE, OVERHEAD VALUE SINGLE CYLINDER FUEL TANK: 5.3 LITRES OF UNLEADED PETROL MAXIMUM PUMPING CAPACITY:78000 L/H ACCESSORIES: X 6 PLASTIC DELIVERY PIPES WITH STRAINER AND FITTINGS 2. 6 KVA 200A DIESEL WELDER/GENERATOR - ELECTRICAL START POWER OUTPUT:5.7 KW WITH 230V SINGLE CYLINDER VERTICAL 4-STROKE ENGINE WITH AIR-COOLED FUEL TANK CAPACITY 5.5 L 3. X2 DUAL VOLTAGE INVERTER WELDER INPUT CURRENT 39.3A AND INPUT POWER 9KVA WELDING CURRENT 20 - 200A POWER FACTOR 0.7 WITH 85% EFFICIENCY

RFQ – REQUEST FOR QUOTATION FOR REMOVAL OF BEES AT VAALKOP, HEAD OFFICE, MMABATHO REGIONAL OFFICE, MMABATHO WTW, MAFIKENG WTW, TSWASA WTW, LOKALENG PUMPSTATION, MOTSWEDI WTW, INTERMEDIATE PUMPSTATION, MOLATEDI DAM, MOROKWENG OFFICE, GANYESA DISTRICT, PUDIMOE WTW, TAUNG DISTRICT, HARTSWATER, KGOMOTSO WTW, CHRISTIANA WTW, CHRISTIANA WWTW, BLOEMHOF WTW, BLOEMHOF WWTW, LEEUDORINGSTAD, WALLMANNSTHAL, KLIPDRIFT AND CULLINAN FOR A PERIOD OF 6 MONTHS

RFQ – REQUEST FOR QUOTATION FOR REMOVAL OF BEES AT VAALKOP, HEAD OFFICE, MMABATHO REGIONAL OFFICE, MMABATHO WTW, MAFIKENG WTW, TSWASA WTW, LOKALENG PUMPSTATION, MOTSWEDI WTW, INTERMEDIATE PUMPSTATION, MOLATEDI DAM, MOROKWENG OFFICE, GANYESA DISTRICT, PUDIMOE WTW, TAUNG DISTRICT, HARTSWATER, KGOMOTSO WTW, CHRISTIANA WTW, CHRISTIANA WWTW, BLOEMHOF WTW, BLOEMHOF WWTW, LEEUDORINGSTAD, WALLMANNSTHAL, KLIPDRIFT AND CULLINAN FOR A PERIOD OF 6 MONTHS

RFQ – REQUEST FOR QUOTATION FOR DRILLING AND EQUIPPING OF 2X BOREHOLES IN WOLMARANSTAD MAQUASIHILL LM CSI PROJECT 2025/26 SCOPE OF WORK & SPECIFICATION PROJECT: TESTING (GEO – HYDROGEOLOGICAL STUDY, DEPTH, YIELD AND WATER QUALITY), RE-DRILLING, AND EQUIPPING OF A BOREHOLE WITH PUMP HOUSE, VALVES, AND FLOW METER IN MAQUASSI HILL LOCAL MUNICIPALITY - LOBALENG 1. BACKGROUND & OBJECTIVES MAGALIES WATER INTENDS TO DEVELOP A RELIABLE GROUNDWATER SOURCE TO AUGMENT POTABLE WATER SUPPLY FOR THE COMMUNITY. THE WORKS INVOLVE RE-DRILLING, TESTING, EQUIPPING OF A BOREHOLE, AND CONSTRUCTION OF A PUMP HOUSE COMPLETE WITH FITTINGS AND INSTRUMENTATION. 2. SCOPE OF WORK 2.1 DRILLING AND CONSTRUCTION OF BOREHOLE • SITE ESTABLISHMENT, INCLUDING SETTING OUT AND FENCING. • DRILLING OF A BOREHOLE TO AN ESTIMATED DEPTH OF [ E.G., 100M], OR AS DETERMINED BY HYDROGEOLOGICAL CONDITIONS. • SUPPLY AND INSTALLATION OF STEEL/PVC CASING AND WELL SCREEN IN LINE WITH BOREHOLE DESIGN. • GRAVEL PACKING, GROUTING, AND WELL DEVELOPMENT BY AIR-LIFT/PUMPING. • BOREHOLE LOGGING (GEOLOGICAL, CONSTRUCTION, AND HYDROGEOLOGICAL). 2.2 BOREHOLE TESTING • STEP-DRAWDOWN PUMPING TEST. • 24-HOUR CONSTANT RATE PUMPING TEST AT SUSTAINABLE YIELD. • RECOVERY TEST. • COLLECTION OF WATER SAMPLES FOR CHEMICAL AND BACTERIOLOGICAL ANALYSIS (TO BE TESTED AT AN ACCREDITED LABORATORY)

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF : 1. MONO PIPE 50MM X 3M 100 2. MONO PIPE 65MM X 3M 50 3. STAND PIPES GALV 20MM X 1M SUPPLY AND DELIVERY: - 1. V-BELT 17X1060 20 2. V-BELT 17X1080 20 3. V-BELT 17 X 3700 20 4. VARIANT AIR VALVE MODEL 080 L X25 SIZE 80MM FLANGED 8 BOLTS 10 5. PLASSON MALE ADAPTOR 20MM X 20MM 200 6. SOCKETS (20MM GALVANIZED) 100 7. GALV. RED SOCKET (25X20MM) 50 8. T-PIECE (50MM BSP - GALVANIZED) 10 9. PLASSON MALE ADAPTOR 110MMX90MM

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY: - 1. MONO PIPE 50MM X 3M 100 2. MONO PIPE 65MM X 3M 50 3. STAND PIPES GALV 20MM X 1M

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY: - 1. MONO PIPE 50MM X 3M 100 2. MONO PIPE 65MM X 3M 50 3. STAND PIPES GALV 20MM X 1M

RFQ – REQUEST FOR QUOTATION TO SUPPLY AND INSTALL POLE MOUNTED TRANSFORMER: - SCOPE: 100 KVA/400V TRANSFORMER, 3 PHASE – SUPPLY AND INSTALL MANDATORY REQUIREMENT: - 1.BIDDER TO SUBMIT CIDB GRADE1 ELECTRICAL 2.COMPULSORY SITE BRIEFING MEETING POINT @09H00 – LEEUDORINGSTAD PUMP STATION THEN ALL DRIVE TO WOLMARNAS BOREHOLES FOR 10H00 BRIEFING MEETING DATE: 28 APRIL 2026 @ 10H00 CONTACT PERSON: MR. THOMAS RIBOMBO 069 019 6240 BIDDERS TO WEAR CORRECT PPE TO ENTER THE PLANT FOR BRIEFING

RFQ – REQUEST FOR QUOTATION FOR REPAIRING A TRANSFORMER : SCOPE OF WORK: THE TRANSFORMERS (1 BLOEMHOF AND 2 CHRISTIANA) ARE CURRENTLY EXPERIENCING AN OIL LEAK. TRANSFORMER OIL IS CRITICAL FOR INSULATION AND COOLING. CONTINUED LEAKAGE MAY LEAD TO OVERHEATING, INSULATION FAILURE, AND TOTAL TRANSFORMER BREAKDOWN. IMMEDIATE CORRECTIVE ACTION IS REQUIRED TO PREVENT PLANT FAILURE AND SAFETY HAZARDS. CORRECTIVE ACTIONS: - 1. REPAIR DAMAGED GASKETS OR SEALS 2. REPAIR RADIATOR OR TANK LEAKS 3. TIGHTEN LOOSE BOLTS AND FITTINGS 4. PRESSURE TEST FOR LEAK CONFIRMATION MANDATORY REQUIREMENTS: - 1. BIDDER TO SUBMIT CIDB GRADING 2EP OR HIGHER. 2. BIDDER TO ATTACH QUALIFICATION FOR PERSONNEL – NATIONAL DIPLOMA OR HIGHER IN ELECTRICAL. 3. ATTACH CV WITH MINIMUM OF THREE (3) YEARS’ EXPERIENCE IN REPAIRING TRANSFORMERS. 3. SITE VISIT COMPULSORY 29 APRIL 2026 PLACE: BLOEMHOF WTW PLANT @10H00 THEN MOVE TO CHRISTIANA PLANT CONTACT PERSON: MR. THOMAS RIBOMBO 069 019 6240 BIDDERS TO WEAR CORRECT PPE TO ENTER THE PLANT FOR BRIEFING

RFQ – REQUEST FOR QUOTATION TO INVITE PROFESSIONAL SERVICE PROVIDERS TO SUBMIT QUOTATIONS TO SUPPLY AND INSTALLATION OF NEAR OR REAL TIME WATER TELEMETRY SYSTEM AND DATA TRANSMISSION SYSTEM (4IR TECHNOLOGY) FOR PORTABLE WATER AT BUISFONTEIN RESERVOIR. SYSTEM FUNCTIONALITY REQUIREMENTS: - THE TECHNOLOGY THAT WILL ASSIST IN MONITORING AND REPORTING THE FOLLOWING NOT LIMITED PARAMETERS IN REAL TIME. 1. WATER VOLUME 2. RESERVOIRS’ WATER LEVELS 3. LEAKAGE DETECTION 4. APPARENT WATER LOOSES MONITORING AND REPORTING 5. WATER FLOWRATE MONITORING AND REPORTING 6. PRESSURE MONITORING AND REPORTING 7. REPORTING AND ACCESSIBILITY 8. THE SYSTEM MUST BE ACCESSIBLE THROUGH MOBILE DEVICE, COMPUTER, LAPTOP IN REAL TIME 23/7. 9. THE SYSTEM MUST HAVE A HEAT MAP DASHBOARD THAT SHOW PROBLEMATIC AREAS PER PARAMETER FOR PROACTIVE MEASURES. 10. PROVIDE SYSTEM DASHBOARDS IN REAL-TIME PROVIDING WATER LEVELS,PRESSURE, WATER QUALITY, FLOWRATES, AND OTHER RELEVANT PARAMETERS. 11. THE ABILITY TO CREATE REPORTS THAT CAN BE PRODUCED HOURLY, DAILY, WEEKLY OR MONTHLY DEPENDING ON THE REQUIREMENTS OF MAGALIES WATER. 12. COMPUTE WATER DISTRIBUTION AND CONSUMPTION REPORTS PER SITES 13. COMPUTE WATER LOSS REPORTS AND CHARTS ALONG THE WATER DISTRIBUTION NETWORK

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF AIR RELEASE VALVES TO HARTSWATER STORES VARIANT COMBINATION AIR RELEASE AND VACUUM BREAK MODEL: 080LX25 SIZE: 80MM PRESSURE RATING: 2500KPA NO. OF BOLTS: 8 TYPE: FLANGED

RFQ – REQUEST FOR QUOTATION TO REPAIR AND RE-INSTALL OF CRITICAL HIGH LIFT TWO PUMPS AND TWO MOTOR OF BLOEMHOF WATER PLANT. THE PLANT IS CURRENTLY OPERATING WITH ONLY TWO HIGH LIFT PUMPS, WITH NO STANDY UNIT AVAILABLE. ONE OF THE PUMPS IS NOT SUFFICIENT TO MEET FULL OPERATIONAL DEMAND, IN THE EVENT THAT ONE PUMP FAILS OR TRIPS, THE PLANT WILL BE FORCED TO SHUT DOWN, RESULTING IN: 1. INTERRUPTION OF WATER SUPPLY 2. OPERATIONAL DOWNTIME 3. RISK TO SERVICE DELIVERY 4. POSSIBLE EQUIPMENT DAMAGE DUE MANDATORY REQUIREMENTS: - 1. BIDDER TO SUBMIT CIDB GRADING 2EP OR HIGHER. 2. BIDDER TO ATTACH QUALIFICATION FOR PERSONNEL – NATIONAL DIPLOMA OR HIGHER IN ELECTRICAL. 3. ATTACH CV WITH MINIMUM OF THREE (3) YEARS’ EXPERIENCE IN REPAIRING TRANSFORMERS. 3. SITE VISIT COMPULSORY 24 APRIL 2026 PLACE: BLOEMHOF WTW PLANT @10H00 CONTACT PERSON: MR. THOMAS RIBOMBO 069 019 6240 BIDDERS TO WEAR CORRECT PPE TO ENTER THE PLANT FOR BRIEFING

RFQ – REQUEST FOR QUOTATION FOR BIO-MONITORING PROGRAMME DEVELOPMENT AND IMPLEMENTATION FOR VAALKOP WATER TREATMENT WORKS 1. BACKGROUND MAGALIES WATER, OPERATING UNDER WATER USE LICENCE NO. 27/2/2/A921/104/1, IS REQUIRED TO IMPLEMENT A BIO-MONITORING PROGRAMME TO ASSESS THE ECOLOGICAL IMPACTS OF EFFLUENT DISCHARGE FROM VAALKOP WATER TREATMENT WORKS INTO THE RECEIVING WATER RESOURCE. THIS RFQ SEEKS QUALIFIED SERVICE PROVIDERS TO DESIGN, IMPLEMENT, AND REPORT ON BIO-MONITORING ACTIVITIES IN COMPLIANCE WITH LICENCE CONDITIONS. 2. SCOPE OF WORK THE APPOINTED SERVICE PROVIDER MUST: 2.1 ESTABLISH A BIO-MONITORING PROGRAMME WITHIN THREE (3) MONTHS OF CONTRACT AWARD. 2.2 CONDUCT WATER QUALITY AND INVERTEBRATE HABITAT ASSESSMENTS AT THREE SITES: 2.2.1 UPSTREAM REFERENCE CONDITION 2.2.2 DISCHARGE POINT 2.2.3 DOWNSTREAM OF THE DISCHARGE POINT 2.3 APPLY THE INVERTEBRATE HABITAT ASSESSMENT SYSTEM (IHAS) AND SOUTH AFRICAN SCORING SYSTEM (SASS) METHODOLOGIES. 2.4 UNDERTAKE SEASONAL SAMPLING (SUMMER AND WINTER). 2.5 COMPARE RESULTS AGAINST REFERENCE CONDITIONS WITHIN THE SAME ECO-REGION

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY STORES ITEMS 1. TAP PLASTIC 20MM 500 2. COUPLING PLASSON 20MM 200 3. COUPLING PLASSON 25X20MM 150 4. CASCADE CLAMP (CRI-0600-12) 150-161 50 5. ELBOW GALVANISED F/F 20MM 200 6. NIPPLES (GALVANIZED - 20MM) 200 7. NIPPLES (40MM - BARREL GALVANIZED) 50 8. PLUGS HOLLOW (20MM GALVANIZED) 100 9. COUPLING PLASSON 25MM 100 10. COUPLING PLASSON 50MM 100 11. STAND PIPES GALV 20MM X 1M 50 12. M12 X 50MM BOLTS 50 13. BOLTS & NUTS (H/T - 20MMX80MM)

RFQ – REQUEST FOR QUOTATION FOR QUALIFIED AUCTIONEERS TO FACILITATE THE SALE OF ASSETS EARMARKED FOR DISPOSAL. THE DISPOSAL LIST INCLUDES MOTOR VEHICLES, IT ASSETS, AND OTHER EQUIPMENT

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF WELDING RODS 1. WELD RODS FLEET WELD 4.0 X350MM 22.7KG 5 2. WELD RODS FLEET WELD 4.8 X350MM 22.7KG 6 3. WELDING RODS 3.15MM 5KG VITEMAX GEN PURP 15 4. AFROX ROD WELDING 2.50MM 5KG BOX X15 15 5. BLADE DIAMOND FRAG 230MM (T00B204) 20 6. STEEL CUTTING DISC (EHT 80-125-2 A24) SUPER FLEX 150 7. STEEL GRINDING DISC (E230 6A 24SG) SUPER FLEX 50 8. STEEL GRINDING DISC 80E115'6 A24PS 115MM SUPER FLEX

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF IFM THREAD M12 1. IFM PN3092 (BSP) G 1/4 THREAD M12 IFM PN3092 (BSP) G 1/4 THREAD M12 4-20MA, 0-300 BAR 18-30 VDC M12 8 2. IFM PN3094 (BSP) G 1/4 THREAD M12 IFM PN3094 (BSP) G 1/4 THREAD M12 4-20 MA 0-10 BAR 18-30 VDC 8 3. IFM SI 5000 FBW SENSOR IFM SI 5000 FBW SENSOR 19-36 VOLT, STAINLESS 316 L M12 8 4. IFM E40124 WELDING ADAPTOR M18X1,5 IFM E40124 WELDING ADAPTOR M18X1,5 - O 24 STAINLESS S-316 L 6 5. IFM E30047 PROGRESSIVE RING FITTING IFM E30047 PROGRESSIVE RING FITTING FOR TEMP SENSOR O6MM G 1/2 STAINLESS STEEL 316L 6 6. IFM E33431 PROGRESIVE RING FITTING IFM E33431 PROGRESIVE RING FITTING G 1/4 STAINLESS STEEL 316L

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY: - 1. TAP PLASTIC 20MM 350 2. HDPE PIPE (20MM X 100M - C16 Q/NO AZ 112) 20X100 ROLL 2000 3. PIPE UPVC 355MM X 3M

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY: - 1. CASCADE CLAMP (CR1 0900-08) 229-238 20 2. CASCADE CLAMP (CRI-0600-08) 150-161 20 3. CASCADE CLAMP (CR1-0238-06) 59-67 50 4. CASCADE CLAMP CR1-0790-12 10 5. CASCADE CR2-390/410-32(800MM WIDE) 10 6. CASCADE CLAMP (CR1 790-08) 196-205 10 7. CASCADE CLAMP (CR1 690-08) 174-183 10 8. CASCADE CLAMPS CR1-1400-16 10 9. KLINGER PIPE COUPLING TC0350 L300 (LONG) DN 300 (344MM -360MM) 10 10. KLINGER PIPE COUPLING TC0350 L300 (LONG) DN 250 (272MM -289MM) 10 11. STRAIGHT COUPLING TC 250 272-289

RFQ – REQUEST FOR QUOTATION FOR DRILLING, TESTING, AND EQUIPPING OF A BOREHOLE WITH PUMP HOUSE, VALVES, AND FLOW METER AT ROEDTAN IN MODIMOLLE-MOOKGOPONG LM. 1. BACKGROUND & OBJECTIVES MAGALIES WATER INTENDS TO DEVELOP A RELIABLE GROUNDWATER SOURCE TO AUGMENT POTABLE WATER SUPPLY FOR THE COMMUNITY. THE WORKS INVOLVE BOREHOLE EXPLORATION STUDIES, DRILLING, TESTING, EQUIPPING OF A BOREHOLE, AND CONSTRUCTION OF A PUMP HOUSE COMPLETE WITH FITTINGS AND INSTRUMENTATION. 2. SCOPE OF WORK 2.1 GEOHYDROLOGICAL STUDY AND SITTING 2.2 DRILLING AND CONSTRUCTION OF BOREHOLE • SITE ESTABLISHMENT, INCLUDING SETTING OUT AND FENCING (IF REQUIRED). • DRILLING OF A BOREHOLE TO AN ESTIMATED DEPTH OF [INSERT DEPTH, E.G., 150M], OR AS DETERMINED BY HYDROGEOLOGICAL CONDITIONS. • SUPPLY AND INSTALLATION OF STEEL/PVC CASING AND WELL SCREEN IN LINE WITH BOREHOLE DESIGN. • GRAVEL PACKING, GROUTING, AND WELL DEVELOPMENT BY AIR-LIFT/PUMPING. • BOREHOLE LOGGING (GEOLOGICAL, CONSTRUCTION, AND HYDROGEOLOGICAL). 2.3 BOREHOLE TESTING

RFQ – REQUEST FOR QUOTATION FOR DRILLING, TESTING, AND EQUIPPING OF A BOREHOLE WITH PUMP HOUSE, VALVES, AND FLOW METER FOR 2 X BOREHOLES AT MMUKUBYANE AND CYFERSKUIL VILLAGES IN MORETELE LM, AND INSTALLATION OF A WATER TREATMENT FACILITY TO ACCEPTABLE STANDARDS. 1. BACKGROUND & OBJECTIVES MAGALIES WATER INTENDS TO DEVELOP A RELIABLE GROUNDWATER SOURCE TO AUGMENT POTABLE WATER SUPPLY FOR THE COMMUNITY. THE WORKS INVOLVE BOREHOLE EXPLORATION STUDIES, DRILLING, TESTING, EQUIPPING OF A BOREHOLE, AND CONSTRUCTION OF A PUMP HOUSE COMPLETE WITH FITTINGS AND INSTRUMENTATION. 2. SCOPE OF WORK 2.1 GEOHYDROLOGICAL STUDY AND SITTING 2.2 DRILLING AND CONSTRUCTION OF BOREHOLE • SITE ESTABLISHMENT, INCLUDING SETTING OUT AND FENCING (IF REQUIRED). • DRILLING OF A BOREHOLE TO AN ESTIMATED DEPTH OF [INSERT DEPTH, E.G., 150M], OR AS DETERMINED BY HYDROGEOLOGICAL CONDITIONS. • SUPPLY AND INSTALLATION OF STEEL/PVC CASING AND WELL SCREEN IN LINE WITH BOREHOLE DESIGN. • GRAVEL PACKING, GROUTING, AND WELL DEVELOPMENT BY AIR-LIFT/PUMPING. • BOREHOLE LOGGING (GEOLOGICAL, CONSTRUCTION, AND HYDROGEOLOGICAL)

RFQ – REQUEST FOR QUOTATION TO SUPPLY AND DELIVER THE FOLLOWING SPARES FOR THE SAND FILTER: M16 STAINLESS STEEL U-BOLTS FOR A 300MM STAINLESS STEEL PIPE X 60. M16 HEX STAINLESS STEEL NUTS X 120. M16 STAINLESS STEEL FLAT WASHERS X 120. M10 STAINLESS STEEL U-BOLTS FOR A 100MM UPVC PIPE X 80. M10 HEX STAINLESS STEEL NUTS X 160. M10 STAINLESS STEEL FLAT WASHERS X 160. DAF DEFFUSER NOZZLES X 40. (SAMPLE AVAILABLE ON SITE) 40MM X 6M STAINLESS STEEL ANGLE IRON X 2

RFQ – REQUEST FOR QUOTATION TO CARRY OUT A COMPREHENSIVE SEERVICE OF CHLORINE DIOXIDE GENERATOR SYSTEM. SUPPLY AND INSTALL A ROTAMETER SERVICE KIT. REPALCE ROTAMETER FLOW TUBE. INSPECT THE FLOAT, GUIDE AND END FITTING FOR WEAR OR CHEMICAL ATTACKS. SUPPLY AND REPLACE ALL RELEVANT SEAL KIT ASSOCIATED WITH CHEMICAL DOSING LINES AND REATOR CONNECTIONS. REMOVE AND SERVICE/INSTALL NEW PH PROBE. INSPECT CABLE, CONNECTOR, AND TRANSMITTER INPUT. REMOVE AND INSPECT PADDLE TYPE FLOW METER. REPALCE OR SERVICE THE METER. REPAIR HMI TOUCH FILAMENT, REPAIR OR REPLACE HMI TOUCH INTERFACE/ FILAMENT. TESTING AND COMMISSIONING: CONDUCT LEAK CHECKS ON ALL DISTURBED JOINTS. VERIFY STABLE AND ACCURATE PH READING. CONFIRM NO ACTIVE FAULTS OR ALARM RELATED TO SERVICED COMPONENTS. DOCUMENTATION: PROVIDE DETAILED INSPECTION REPORTS, PARTS REPLACED, AND TEST RESULTS. A SHE FILE MUST BE SUBMITTED WITHIN 7 DAYS OF RECEIVING THE PO. CONTRACTOR MUST ATTACH A LETTER OF GOOD STANDING. CONTRACTOR MUST HAVE A PROVEN EXPERIENCE OF SERVICING/REFURBISHMENT OF CHLORINE DIOXIDE GENERATOR

RFQ – REQUEST FOR QUOTATION FOR SENCO BLOWER REFURBISHMENT. DISASSEMBLE CASING, ROTORS, SHAFT, BEARINGS, SEALS, TIMING GEARS, LUBRICANT SYSTEM AND MOTOR. INSPECT PARTS FOR WEAR OR DAMAGE, MEASURE CLEARENCES VS OEM TOLERANCES. REPLACE WORN ROTOR LOBES, SHAFT, OR GEARS BEYOND TOLERANCE. REPLACE ALL BEARINGS EVEN IF WITHIN LIMITS. REPLACE LIP SEALS, O-RING, GASKETS AND BREATHER ELEMENTS. CLEAN AND POLISH ROTOR LOBES, INSPECT HOUSING BORE FOR ROUNDNESS MEASURE ROTOR-TO-CASING CLEARANCE. REFINISH CASING. REASSEMBLE PER OEM TORQUE SPECIFICATIONS. MAKE SURE THE NOISE LEVEL AND VIBRATION ARE WITHIN THE THE OEM SPECIFICATIONS. DOCUMENTATION: PROVIDE DETAILED INSPECTION REPORTS, PARTS REPLACED, AND TEST RESULTS. A PERIOD OF 6 MONTHS WARRANTY MUST BE STATED IN WRITTING. A LETTER OF GOOD STANDING MUST BE ATTACHED TOGETHER WITH THE QUOTATIONS. A SHE FILE MUST BE SUBMITTED WITHIN 7 DAYS OF RECEIVING THE PO. EXPERINCE: CONTRACTOR MUST HAVE A PROVEN EXPERIENCE ON REFURBISHMENT OF SIMILAR BLOWERS. PROVIDE EVIDENCE OF HAVING REFURBISHED SIMILAR SIZE UNIT. PROVIDE PROOF OF QUALIFIED ARTISAN OR TECHNICIAN. WORKSHOP AND TECHNICAL CAPABILITY: CONTRACTOR MUST HAVE A FULLY EQUIPPED MECHANICAL WORKSHOP CAPABLE OF PRECISION SHAFT AND ROTOR MEASUREMENT. BEARING AND GEAR INSTALLATION USING PROPER TOOLS. PROPER LIFTING EQUIPMENT. SPECIFICATION OF THE BLOWER: SENCO. MODEL URAI59M

RFQ – REQUEST FOR QUOTATION FOR SOURCING OF A SECURITY SERVICE PROVIDER TO SAFEGUARD ROOIGROND WATER TREATMENT PLANT THAT IS UNDER CONSTRUCTION FOR A PERIOD OF SIX MONTHS WHILE THE CONTRACTOR IS SOURCED TO COMPLETE THE UNFINISHED PROJECT

RFQ – REQUEST FOR QUOTATION FOR LIME DOSING SYSTEM PARTIAL UPGRADE: THE CURRENT LIME SYSTEM IS NOT WORKING PROPERLY, AND ITS OPERATION POSES A HEALTH HAZARD TO THE COMMUNITY AND THE WORKERS WHICH IS IN CONTRAVENTION OF SANS 241 AND OCCUPATIONAL HEALTH AND SAFETY ACT & REGULATIONS: ACT 85 OF 1993 RESPECTIVELY. THE PROPOSED UPGRADE WILL INCLUDE THE FOLLOWING: •SUPPLY AND DELIVER OF A COUNTER-BALANCE LIFTER / STACKER RETRACTABLE WITH THE FOLLOWING SPECIFICATIONS: - CAPACITY = 1500KG - LOAD CENTRE = 600MM - LIFTING HEIGHT = 3000MM - LOWERED HEIGHT = 90MM - GROUND CLEARANCE = 30MM - LENGTH OF FORK = 1125MM - WIDTH ACROSS FORKS = 680MM - BATTERY / CHARGER = 2 X 12V/75AH - WHEEL BASE = 1235MM - MINIMUM TURNING RADIUS = 1340MM - DRIVER MOTOR = 24V/600W - LIFT MOTOR = 24V/2200W - OVERALL LENGTH = 1720MM - OVERALL WIDTH = 800MM - OVERALL HEIGHT = 2035MM - WEIGHT = 355KG •CUTTING OF AN OPENING IN THE STORAGE ROOM WALL FACING THE FILTERS AND THE INSTALLATION OF AN INDUSTRIAL ROLL UP DOOR. THE OPENING MUST BE 2400MM (W) X 2500MM (H)

RFQ – REQUEST FOR QUOTATION FOR TRAINING – HIRA

RFQ – REQUEST FOR QUOTATION FOR TRAINING - CONFINED SPACE

RFQ – REQUEST FOR QUOTATION FOR NEW OVERHEAD FIBRE LINE INSTALLATION: INSTALLATION OF NEW OVERHEARD FIBRE ROUTE: PODUMOE WTP: - NUMBER OF BUILDINGS: (BUILDING A TO BUILDING B). X3 (BUILDING B TO BUILDING C). - 9U CABINET WALLMOUNT 600W X 450D GLASS DOOR. X2 - 6 WAY ALUMINIUM MOULDED RACK MOUNT PDU.X2 - 24-PORT CAT6 RACK MOUNT PATCH PANEL.X2 - 1U BRUSH PANEL. X2 - HIGH SURGE PROTECTION ADAPTOR (RED). X3 FIBRE INSTALLATION: - OVERHEAD ROUTE. X2 - FIBRE CABLE.X3 - LC TO LC UPC MULTI MODE DUPLEX. X4 - LABOUR. X1 - FIBRE SPLICING. X3 - GALVANISED STEEL HOOK ON FACE PLATE WIRE ROPE LASHING CABLE WALL MOUNT. X4 INSTALLATION OF NEW OVERHEARD FIBRE ROUTE: BLOEMHOF WTP: - NUMBER OF BUILDINGS: X2 (BUILDING A TO BUILDING B). - 9U CABINET WALLMOUNT 600W X 450D GLASS DOOR. X1 - 6 WAY ALUMINIUM MOULDED RACK MOUNT PDU. X1 - 24-PORT CAT6 RACK MOUNT PATCH PANEL. X1 - 1U BRUSH PANEL. X1 - HIGH SURGE PROTECTION ADAPTOR (RED). X2

”RFQ

RFQ – REQUEST FOR QUOTATION FOR SLUDGE CLASSIFICATION, ANALYSIS, REPORT AND INTERPRETATION FOR TAUNG, SCHWEIZER RENEKE, CHRISTIANA, BLOEMHOF, PUDIMOE, KGOMOTSO, MMABATHO, MOTSWEDI WATER TREATMENT PLANT. THE APPLICANT SHOULD POSSESS: 1. A QUALIFICATION IN ENVIRONMENTAL SCIENCES OR ENVIRONMENTAL MANAGEMENT (MINIMUM REQUIREMENT: DEGREE), ATTACH PROOF OF QUALIFICATION) 2. MINIMUM OF 3+ YEARS’ EXPERIENCE IN SLUDGE SAMPLING AND CLASSIFICATION. (ATTACH CONTACTABLE REFERENCE LETTER) 3. REGISTRATION WITH PROFESSIONAL BODIES I.E. SACNSP AND EAPASA. (ATTACH PROOF OF REGISTRATION) SLUDGE CLASSIFICATION SPECIFICATIONS 1. COMPLIANCE & LEGAL REQUIREMENTS A) LEGALLY REGISTERED COMPANY B) KNOWLEDGE OF ENVIRONMENTAL COMPLIANCE (WASTE MANAGEMENT, ENVIRONMENTAL IMPACT ASSESSMENT (EIA), NATIONAL WASTE REGULATIONS (E.G., SOUTH AFRICA: NEM:WA & WASTE CLASSIFICATION REGULATIONS) C) OCCUPATIONAL HEALTH & SAFETY (OHS) COMPLIANCE D) SAFETY FILES SPECIFIC TO SLUDGE HANDLING E) RISK ASSESSMENTS & METHOD STATEMENTS (RAMS)

RFQ – REQUEST FOR QUOTATION TO REPLACE CRACKED VC GAS FEEDER UNIT. REPLACEMENT OF THE EXISTING CRACKED VC GAS FEEDER UNIT (W3T174962-V10K) AND ENSURE SAFE, RELIABLE, AND ACCURATE CHLORINE GAS DOSING OPERATION. SUPPLY A COMPLETE REPLACEMENT UNIT MATCHING THE TECHNICAL SPECIFICATIONS PROVIDED. ENSURE COMPATIBILITY WITH THE EXISTING CHLORINE GAS DOSING SYSTEM AND PIPEWORK. DELIVER ALL MOUNTING ACCESSORIES, FASTENERS, AND GASKETS REQUIRED FOR INSTALLATION. PROVIDE COC AND MANUFACTURE'S DATA SHEET WITH DELIVERY. THE REPLACEMENT UNIT MUST BE FACTORY CALIBRATED AND TESTED BEFORE DISPATCH. WARRANTY AND DOCUMENTATION: MINIMUM 12 MONTH WARRANTY FROM DATE OF COMMISSIONING. SUPPLY OPERATION AND MAINTENANCE MANUAL. PROVIDE CALIBRATION AND TEST CERTIFICATES. EQUIPMENT DETAIL: MODEL; VC GAS FEEDER V10K. TYPE; REMOTE VACUUM GAS CONTROL UNIT. CAPACITY: 10KG/H. TAG: W3T174962. MOUNTING: WALL MOUNTED DESIGN. MANUFACTURER/EQUIVALENT: ORIGINAL OR EQUIVALENT APPROVED MODEL. SHE FILE MUST BE SUBMITTED WITHIN 7 DAYS OF RECEIVING THE ORDER. ATTACH A LETTER OF GOOD STANDING. SANS 10265 AND APPLICABLE CHLORINE GAS HANDLING STANDARDS

RFQ – REQUEST FOR QUOTATION TO SUPPLY AND DELIVER LIME DOSING PUMP. SUPPLY, DELIVER, INSTALL, CONNECT, TEST, COMMISION AND HAND OVER A COMPLETE STANDBY LIME DOSING PUMP SYSTEM FOR OPERATIONAL USE. THE SYSTEM MUST BE SUPPLIED AS A COMPLETE, READY-TO-OPERATE PACKAGE, INCLUDING ALL MECHANICAL, ELECTRICAL, AND STRUCTURAL COMPONENTS REQUIRED FOR SAFE OPERATION. PUMP MUST BE SUITABLE FOR HANDLING ABRASIVE LIME SLURRY. CONTINUOUS AND INTERMITTENT OPERATION. CORROSION-RESISTANT WETTED PARTS. CONTRACTOR MUST CONFIRM, FLOW RATE, DISCHARGE PRESSURE, MOTOR POWER RATING, SPEED AND PUMP CURVE. THE PUMP SET MUST BE SUPPLIED COMPLETE WITH, PUMP AND GEAR UNIT. ELECTRIC MOTOR. HEAVY DUTY BASE FRAME (PAINTED, CORROSION PROTECTED) ALL FASTENERS IN CORROSION RESISTANT MATERIAL. CONNECT SUCTION AND DISCHARGE PIPEWORK TO EXIXTING SYSTEM. LEAK TEST MUST BE PERFOEMED AFTER INSTALLATION. DOCUMENTATION: HANDOVER THE OPERATION AND MAINTENANCE MANUALS. PUMP DATASHEET WITH PERFORMANCE CURVE. ELECTRIC MOTOR DATASHEET. RECOMMENDED MAINTENANCE SCHEDULE. WARRANY CERTIFICATE. A SHE FILE MUST BE SUBMITTED WITHIN 7 DAYS OF RECEIVING THE PO. COIDA MUST BE ATTACHED TO QUOTATION. EXPERIENCE: CONTRACTOR MUST HAVE PROVEN EXPERIENCE IN MAINTENANCDE OR INSTALLATION OF SIMILAR PUMP. PROVIDE EVIDENCE OF HAVING WORKED ON PUMPS PUMP SPEC:MODEL MONO C31M 0004A. SERIAL NUMBER 23H83-22-00005F OR APPROVED EQUIVALENT

RFQ – REQUEST FOR QUOTATION FOR SUPPLY, DELIVERY, AND INSTALLATION OF A NEW ROTARY SCREW COMPRESSOR. REPLACEMENT OF THE EXISTING AIR COMPRESSOR AT WALLMANNSTHAL WTW WITH A NEW, ENERGY EFFICIENT, AND RELIABLE UNIT TO ENSURE CONTINUOUS AIR SUPPLY FOR PLANT INSTRUMENTATION, PNEUMATIC ACTUATORS, AND PROCESS OPERATIONS. THE NEW COMPRESSOR SHALL BE INSTALLED, TESTED, AND COMMISSIONED AS A FULLY FUNCTIONAL REPLACEMANT FOR THE EXIXTING SYSTEM. SCOPE OF WORK; SITE ASSESSMENT AND VERIFICATION OF THE EXISTING COMPRESSOR INSTALLATION. DISCONNECTION AND SAFE REMOVAL OF THE OLD COMPRESSOR. SUPPLY AND DELIVERY OF A NEW, FACTORY-TESTED AIR COMPRESSOR SYSTEM WITH MATCHING PERFORMANCE. INSTALLATION OF THE NEW COMPRESSOR ON THE EXIXTING OR NEW FOUNDATION. CONNECTION TO THE EXISTING COMPRESSED AIR NETWORK AND ELECTRICAL POWER SUPPLY. INTEGRATION OF CONTROL AND SAFETY SYSTEM. TESTING, COMMISSIONING, AND PERFORMANCE VERIFICATION. TRAINING OF THE OPERATORS AND HANDOVER DOCUMENTATION. UPGRADE THE AIR PIPE NETWORK AND INSTALL WATER TRAPS. SUPPLY AND DELIVER X 6 254 PCE 4 DRAWER 660X310X380 TOOLBOX SET. COMPRESSOR SPEC: ROTARY SCREW COMPRESSOR. POWER RATING 15KW. WORKING PRESSURE 6-10 BAR. DUTY CYCLE 100% CONTINUOUS OPERATION COOLING TYPE AIR COOLED. COMPRESSOR CONFIGURATION FULLY PACKAGED UNIT WITH INTEGRATED AIR DRYER AND FILTERS. RECEIVER TANK 500L HORIZONTAL. CONTROL SYSTEM AUTOMATIC LOAD/UNLOAD CONTROL WITH PRESSURE REGULATION. PROTECTION OVERLOAD, OVER TEMPERATURE, HIGH PRESSURE SHUTDOWN, PHASE FAILURE, LOW OIL PRESSURE. THE SERVICE PROVIDER SHALL PERFORM: MECH ELEC PRE-COMMISSION CHECKS,LEAK AND VIBRATION INSPECTION. THE FOLLOWING DOCS MUST BE SUBMITTED: MANUFACTURER'S DATA SHEET AND PERFORMANCE CURVES. OPERATION AND MAINTENANCE MANUALS. ELEC AND MECH AS-BUILT DRAWING. WARRANTY CERTIFICATE (MIN OF 12 MONTHS)

RFQ – REQUEST FOR QUOTATION FOR ICT MASTER SYSTEMS PLAN AND NETWORK DESIGN SCOPE OF WORK: 1. APPLICATION ARCHITECTURE 2. IT BUSINESS AREA MODEL 3. TECHNOLOGY ARCHITECTURE 4. DATA ARCHITECTURE 5. BUSINESS INTELLIGENCE 6. BUSINESS CONTINUITY (DR) 7. INFRASTRUCTURE ARCHITECTURE 8. SECURITY ARCHITECTURE 9. IT SERVICE DESK

RFQ – REQUEST FOR QUOTATION FOR EMAIL FILTERING AND DOMAIN PROTECTION FOR 12 MONTHS EMAIL FILTERING • ADVANCED SPAM FILTERING USING HEURISTICS AND MACHINE LEARNING • MALWARE AND RANSOMWARE DETECTION (ATTACHMENTS, LINKS) • PHISHING PROTECTION WITH REAL-TIME URL ANALYSIS • QUARANTINE MANAGEMENT AND RELEASE OPTIONS FOR USERS/ADMINS DOMAIN PROTECTION • FULL SUPPORT FOR SPF, DKIM, AND DMARC PROTOCOLS • DMARC REPORTING AND VISUALIZATION TOOLS • ALERTING FOR UNAUTHORIZED DOMAIN USE OR FAILED AUTHENTICATION POLICY ENFORCEMENT • CUSTOMIZABLE RULES FOR CONTENT, ATTACHMENTS, AND RECIPIENTS • DLP FEATURES TO PREVENT SENSITIVE DATA LEAKAGE • ROLE-BASED ACCESS AND AUDIT LOGGING USER EXPERIENCE • WARNING BANNERS FOR SUSPICIOUS EMAILS • SELF-SERVICE QUARANTINE PORTAL • INTEGRATION WITH OUTLOOK, GMAIL, OR OTHER CLIENTS SECURITY & COMPLIANCE • END-TO-END ENCRYPTION FOR EMAIL IN TRANSIT AND AT REST • POPIA, AND OTHER COMPLIANCE SUPPORT • AUDIT TRAILS AND INCIDENT RESPONSE CAPABILITIES • IT CERTIFICATIONS OR RELEVANT QUALIFICATIONS ARE PREFERRED

RFQ – REQUEST FOR QUOTATION TO DIG AND BUILD SEPTIC TANK AT MOROKWENG OFFICE SPECIFICATIONS: DIG 5X3M SEPTIC TANK *BUILD THE SEPTIC TANK AROUND AND A DIVIDING WALL 2.5M APART *REINFORCE BY LENTILS 4M TO SUPPORT TOP CONCRETE SLAB *50M UPVC INSPECTIONS PIPES 0.5M FROM ENDS OF THE LENGTH X 2WITH CAPS. *SEPTIC TANK MANHOLE COVER. *CONNECT THE PIPES FROM THE BUILT NEW BATHROOMS. NB: VERY ROCKY AREA, WE SUGGEST THE SUCCESSFUL BIDDER BENCHMARK FROM COMMUNITY TOILETS PROJECTS CONTRACTOR REGARDING HOW THEY SURVIVE MOROKWENG HARD ROCK. MANDATORY REQUIREMENTS: - 1. CIDB 1GB 2. SITE BRIEFING COMPULSORY @ 10H00, DATE: 14 APRIL 2026. VENUE: MOROKWENG. CONTACT PERSON MR. SIBONGILE DONDOLO 3. ONLY BIDDERS FROM KAGISANO MOLOPO LOCAL MUNICIPALITY (PROVIDE PROOF OF RESIDENCE)

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF WATER QUALITY MONITORING INSTRUMENTS TO BE DELIVERED AT PUDIMOE PLANT. SPECIFICATIONS:- 1. 2 X 2100 QIS01USB2100Q PORTABLE TURBIDIMETER 2. HQ411D BENCHTOP PH/MV METER 3. DR900 MULTIPARAMETER PORTABLE COLORIMETER 4. HQ430D BENCHTOP CONDUCTIVITY METER SUPPLY AND DELIVERY OF WATER QUALITY MONITORING INSTRUMENTS TO BE DELIVERED AT TAUNG PLANT. SPECIFICATION 1.HQ411D BENCHTOP PH/MV METER

RFQ – REQUEST FOR QUOTATION TO SUPPLY AND DELIVER - A PROFESSIONAL GRADE DIGITAL MULTIMETER AND MA LOOP CALIBRATOR WITH CAT IV 600 V/CAT III 1000 V SAFETY RATING- MEANING IT'S DESIGNED FOR HIGH ENERGY ENVIRONMENTS LIKE INDUSTRIAL AND PROCESS CONTROL SYSTEMS. FLUKE 789 PROCESS METER, FLUKE 789 PROCESS METER W/2 LEAD SETS, FLUKE 789 PROCESS METER DIGITAL MULTIMETER- VARIANTS OF THE 789 PROCESS METER WITH ACCESSORIES OR AT DIFFERENT PRICE POINTS, ALL SHARING THE SAME HIGH VOLTAGE CAPABILITY. FLUKE 789 PROCESS SMART - A MORE BUDGET FRIENDLY, STILL BASED ON THE SAME ROBUST PLATFORM

RFQ – REQUEST FOR QUOTATION TO THE PURPOSE OF THIS REQUEST IS TO INVITE PROFESSIONAL SERVICE PROVIDERS TO SUBMIT PROPOSALS TO SUPPLY AND INSTALLATION OF NEAR OR REAL TIME WATER TELEMETRY SYSTEM AND DATA TRANSMISSION SYSTEM (4IR TECHNOLOGY) FOR PORTABLE WATER AT PUDIMOE RESERVOIR AND BOGOSING RESERVOIR. REQUIREMENTS: - THE TECHNOLOGY THAT WILL ASSIST IN MONITORING AND REPORTING OF THE FOLLOWING NOT LIMITED PARAMETERS IN REAL TIME. 1. WATER VOLUME 2. RESERVOIRS’ WATER LEVELS 3. LEAKAGE DETECTION 4. APPARENT WATER LOSES MONITORING AND REPORTING 5. WATER FLOWRATE MONITORING AND REPORTING 6. PRESSURE MONITORING AND REPORTING REPORTING AND ACCESSIBILITY 1. THE SYSTEM MUST BE ACCESSIBLE THROUGH MOBILE DEVICE, COMPUTER, LAPTOP IN REAL TIME 23/7

RFQ – REQUEST FOR QUOTATION TO CONDUCT A SAFETY, HEALTH, AND ENVIRONMENTAL (SHE) LEGAL COMPLIANCE AUDIT AT VAALKOP, BRITS LAB, WALLMANSTHAL, KLIPDRIFT, CULLINAN PLANTS AND HEAD OFFICE- RUSTERNBURG. AUDITORS MUST HAVE A RELEVANT DEGREE IN SAFETY , HEALTH AND ENVIRONMENTAL LAW AND TRAINING IN SAFETY, HEALTH AND ENVIRONMENTAL LAW (SHE LEGAL LIABILITY, OR ENVIRONMENTAL LAW OR OHS ACT AND REGULATIONS). THE COMPANY MUST HAVE MORE THAN 5 YEARS’ EXPERIENCE IN CONDUCTING SHE LEGAL AUDITS. THE COMPANY MUST PROVIDE A DETAILED AUDIT REPORT

RFQ – REQUEST FOR QUOTATION TO ASSIST IN THE IMPLEMENTATION OF ISO 9001 MANAGEMENT SYSTEM PROCEDURES, OPERATING PROCEDURES AND FORMS FOR AREA EAST, WEST, BRITS LAB AND HEAD OFFICE. ASSIST IN CONDUCTING A MANAGEMENT REVIEW ASSIST WITH PREPARATION FOR STAGE ONE AUDIT BY CERTIFICATION BODY. COMPANY MUST BE AN ISO 9001:2015 CONSULTING AND IMPLEMENTING COMPANY. THE COMPANY MUST HAVE MORE THAN 3 YEARS’ EXPERIENCE IN IMPLEMENTATION OF ISO 9001 MANAGEMENT SYSTEM. ATTACH CV AND QUALIFICATIONS

RFQ – REQUEST FOR QUOTATION FOR DESIGN, MANUFACTURE, SUPPLY, INSTALLATION AND COMMISSIONING OF A 1M3/HR REVERSE OSMOSIS POINT OF ENTRY (POE) WATER TREATMENT SYSTEM FOR MAGALIES WATER SCIENTIFIC SERVICES BACKGROUND MAGALIES WATER BOARD IS A SCHEDULE 3(B) PUBLIC ENTITY IN TERMS OF THE PUBLIC FINANCE MANAGEMENT ACT, 1999. MAGALIES WATER’S MANDATE IS TO PROVIDE WATER SERVICES IN TERMS OF SECTION 29 AND ENSURE VIABLE SECTION 30 INITIATIVES AS PRESCRIBED IN THE WATER SERVICES ACT, (ACT NO 108 OF 1997), WHICH PROVIDES THE MANDATE FOR WATER BOARDS. MAGALIES WATER SERVICE AREA COVERS 128 550 KM² ACROSS THE THREE (3) PROVINCES OF NORTH- WEST, LIMPOPO, AND GAUTENG, WITHIN THE MAJOR CATCHMENTS OF THE CROCODILE WEST AND THE PIENAAR’S RIVERS. THIS INCLUDES THE THREE (3) NEW DISTRICT MUNICIPALITIES FROM THE FORMER SEDIBENG WATER WITH CATCHMENTS ON THE LOWER, MIDDLE, AND UPPER VAAL RIVER

RFQ – REQUEST FOR QUOTATION FOR THE REFURBISHMENT OF BLOEMHOF WATER PLANT SAND FILTERS. SCOPE OF WORK: - THE SERVICE PROVIDER TO PERFORM THE FOLLOWING FUNCTIONS: - • REMOVE OLD FILTER SAND AND CLEAN THE FILTER • CLEAN THE FALSE FLOOR • REPLACE ALL FILTER NOZZLES • FILL IN THE NEW SAND AS PER THE ATTACHED SPECIFICATIONS • COMMISSION THE SANDFILTERS • HANDOVER THE PROJECT. LAYER MEDIA SIZE DEPTH: - 1ST LAYER FILTERING MEDIA 0.6 MM – 1.2 MM 700 MM 2ND LAYER COARSE MEDIA 2.36 MM – 4.75 MM 150 MM 3RD LAYER PEBBLE (GRAVEL MEDIA) 6 MM – 13 MM 150 MM. THE SERVICE PROVIDER TO COMMISSION THE SAND FILTERS, FOLLOWED BY THE HANDOVER OF THE PROJECT UPON COMPLETION. MANDATORY REQUIREMENTS: - • CIDB 2 CE • QUALIFICATION OF PERSONNEL: B-TECH CIVIL ENGINEER OR HIGHER, AND REGISTERED WITH ECSA • EXPERIENCE OF PERSONNEL: MUST HAVE MINIMUM 3 YEARS’ EXPERIENCE IN SANDFILTER REFURBISHMENT PROCESS/ KNOWLEDGE OF FILTER OPERATION PRINCIPLE AND MEDIA GRADING/ APPLICATION OF LOCKOUT PROCEDURE. • SITE BRIEFING IS COMPULSORY 9 APRIL 2026 @ 09H00, BLOEMHOF PLANT CONTACT PERSON MR. SOLLY MOKONYAMA

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALL DN400 SUCTION VALVES SUPPLY AND INSTALL 3 OF DN 400 REPLACEMENT SUCTION VALVES. EACH VALVE SHOULD BE SUPPLIED WITH A DN400 FLANGE ADAPTER MANDATORY REQUIREMENT. 1. ME CIDB GRADING (AT LEAST 1 ME)

RFQ – REQUEST FOR QUOTATION FOR INSPECTION AND INTERNAL COATING OF HPH58 3STAGE MANDATORY REQUIREMENT. 1.ME CIDB GRADING (AT LEAST 1 ME) NB: THE QUOTATION SHOULD BE ACCOMPANIED BY THE ABOVE REQUIREMENT. FAILURE TO DO SO WILL RESULT IN THE BIDDER BEING DISQUALIFIED.

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALL PLANT 2 SOUTH SATURATOR TANK X 1 CURRENT VESSEL SPECIFICATION OEM: STYRIA YEAR: 1999 (VESSEL 5893) MAX WORKING PRESSURE: 600KPA CAPACITY: 5.3M3 DESIGN CODE: RSA-CIF-81-95000 PERFORM HYDROSTATIC PRESSURE TESTING ON THE SATURATOR TANK TO 1.3 X DESIGN WORKING PRESSURE, TO DETECT LEAKS, STRUCTURAL WEAKNESSES, OR FLAWS LIKE POOR WELDS, ENSURING THE SYSTEM'S INTEGRITY BEFORE SERVICE AS PER APPLICABLE STANDARDS (FLANGE RATINGS PN40) APPLICABLE STANDARDS 1. PRESSURE EQUIPMENT REGULATIONS (PER), 2009. OCCUPATIONAL HEALTH AND SAFETY ACT, 1993 (ACT NO. 85 OF 1993). 2.SANS 347 SOUTH AFRICAN NATIONAL STANDARD FOR PRESSURE EQUIPMENT SAFETY AND CONFORMITY PERFORM ULTRASONIC TEST AND RADIOGRAPHIC TESTING (RT) ON SATURATOR VESSEL WELDS TO DETECT SUBSURFACE DEFECTS LIKE CRACKS, PORES, OR INCOMPLETE FUSION AS PER APPLICABLE STANDARDS PERFORM ULTRASONIC TEST ON SATURATOR VESSEL WALL TO DETERMINE WALL THICKNESS OF THE GOOSE NECK AS PER APPLICABLE STANDARDS. APPLICABLE STANDARDS 1.ISO 17636: NON-DESTRUCTIVE TESTING OF WELDS—RADIOGRAPHIC TESTING. 2.ISO 9712

RFQ – REQUEST FOR QUOTATION FOR DRILLING AND EQUIPPING OF 3X BOREHOLES IN WOLMARANSTAD (EXT 13, 17 AND 18) MAQUASIHILL LM CSI PROJECT 2025/26 SCOPE OF WORK & SPECIFICATION PROJECT: TESTING (GEO – HYDROGEOLOGICAL STUDY, DEPTH, YIELD AND WATER QUALITY), RE-DRILLING, AND EQUIPPING OF A BOREHOLE WITH PUMP HOUSE, VALVES, AND FLOW METER IN MAQUASSI HILL LOCAL MUNICIPALITY - LOBALENG 1. BACKGROUND & OBJECTIVES MAGALIES WATER INTENDS TO DEVELOP A RELIABLE GROUNDWATER SOURCE TO AUGMENT POTABLE WATER SUPPLY FOR THE COMMUNITY. THE WORKS INVOLVE RE-DRILLING, TESTING, EQUIPPING OF A BOREHOLE, AND CONSTRUCTION OF A PUMP HOUSE COMPLETE WITH FITTINGS AND INSTRUMENTATION. 2. SCOPE OF WORK 2.1 DRILLING AND CONSTRUCTION OF BOREHOLE • SITE ESTABLISHMENT, INCLUDING SETTING OUT AND FENCING. • DRILLING OF A BOREHOLE TO AN ESTIMATED DEPTH OF [ E.G., 100M], OR AS DETERMINED BY HYDROGEOLOGICAL CONDITIONS. • SUPPLY AND INSTALLATION OF STEEL/PVC CASING AND WELL SCREEN IN LINE WITH BOREHOLE DESIGN. • GRAVEL PACKING, GROUTING, AND WELL DEVELOPMENT BY AIR-LIFT/PUMPING. • BOREHOLE LOGGING (GEOLOGICAL, CONSTRUCTION, AND HYDROGEOLOGICAL). 2.2 BOREHOLE TESTING • STEP-DRAWDOWN PUMPING TEST. • 24-HOUR CONSTANT RATE PUMPING TEST AT SUSTAINABLE YIELD. • RECOVERY TEST. • COLLECTION OF WATER SAMPLES FOR CHEMICAL AND BACTERIOLOGICAL ANALYSIS (TO BE TESTED AT AN ACCREDITED LABORATORY)

RFQ – REQUEST FOR QUOTATION FOR SMART MANHOLE LIDS IN THE AREA EAST SUPPLY, CASTING OF REINFORCED CONCRETE, INSTALLATION OF SMART MANHOLE LID BOQ FOR THIS PROJECT WILL BE AVAILABLE AT SITE BRIEFING. A COMPULSORY SITE INSPECTION WILL BE HELD AT KLIPDRIFT AT 11:00 A SITE BRIEFING WILL BE ON 07 APRIL 2026 PPE WILL BE REQUIRED FOR THE BRIEFING, NO PPE, NO ATTENDANCE

RFQ – REQUEST FOR QUOTATION FOR BUILDING OF STRUCTURE AND JOINING TWO - PORTAL FRAMES BOQ FOR THIS PROJECT WILL BE AVAILABLE AT SITE BRIEFING. A COMPULSORY SITE INSPECTION WILL BE CONDUCTED AT KLIPDRIFT AT 10:00 THE BRIEFING WILL BE CONDUCTED 07 APRIL 2026 PPE IS REQUIRED FOR BRIEFING, NO PPE, NO ATTENDANCE

RFQ – REQUEST FOR QUOTATION FOR LIME DOSING SYSTEM PARTIAL UPGRADE: THE CURRENT LIME SYSTEM IS NOT WORKING PROPERLY, AND ITS OPERATION POSES A HEALTH HAZARD TO THE COMMUNITY AND THE WORKERS WHICH IS IN CONTRAVENTION OF SANS 241 AND OCCUPATIONAL HEALTH AND SAFETY ACT & REGULATIONS: ACT 85 OF 1993 RESPECTIVELY. THE PROPOSED UPGRADE WILL INCLUDE THE FOLLOWING: •SUPPLY AND DELIVER OF A COUNTER-BALANCE LIFTER / STACKER RETRACTABLE WITH THE FOLLOWING SPECIFICATIONS: - CAPACITY = 1500KG - LOAD CENTRE = 600MM - LIFTING HEIGHT = 3000MM - LOWERED HEIGHT = 90MM - GROUND CLEARANCE = 30MM - LENGTH OF FORK = 1125MM - WIDTH ACROSS FORKS = 680MM - BATTERY / CHARGER = 2 X 12V/75AH - WHEEL BASE = 1235MM - MINIMUM TURNING RADIUS = 1340MM - DRIVER MOTOR = 24V/600W - LIFT MOTOR = 24V/2200W - OVERALL LENGTH = 1720MM - OVERALL WIDTH = 800MM - OVERALL HEIGHT = 2035MM - WEIGHT = 355KG •CUTTING OF AN OPENING IN THE STORAGE ROOM WALL FACING THE FILTERS AND THE INSTALLATION OF AN INDUSTRIAL ROLL UP DOOR. THE OPENING MUST BE 2400MM (W) X 2500MM (H)

RFQ – REQUEST FOR QUOTATION FOR HIRE OF EXCAVATOR FOR REPAIR OF PIPES BOQ FOR THIS PROJECT WILL BE AVAILABLE AT SITE BRIEFING. A COMPULSORY SITE INSPECTION WILL BE HELD AT KLIPDRIFT AT 11:30 THE BRIEFING WILL BE HELD ON THE 07 APRIL 2026 PPE WILL BE REQUIRED FOR THE BRIEFING, NO PPE, NO ATTENDANCE

RFQ – REQUEST FOR QUOTATION FOR CASTING OF CONCRETE SLAB AT THE RECOVERY PLANT BOQ FOR THIS PROJECT WILL BE AVAILABLE AT SITE BRIEFING. A COMPULSORY SITE INSPECTION WILL BE HELD AT KLIPDRIFT AT 10:30 THE BRIEFING WILL BE ON THE 07 APRIL 2026 PPE WILL BE REQUIRED FOR THE BRIEFING, NO PPE, NO ATTENDANCE

RFQ – REQUEST FOR QUOTATION FOR STATUTORY INSPECTION ON LIFTS PASSENGER LIFT INSPECTION GOODS LIFT INSPECTION AS PER OHS ACT LIFT, ESCALATOR AND PASSENGER CONVEYOR REGULATIONS GNR.828 OF 17 SEPTEMBER 2010 6. INSPECTIONS AND TESTS. —(1) THE USER SHALL ENSURE THAT EVERY LIFT, ESCALATOR OR PASSENGER CONVEYOR IS INSPECTED AND TESTED IN ACCORDANCE WITH THE RELEVANT HEALTH AND SAFETY STANDARDS INCORPORATE MANDATORY REQUIREMENTS LMI CERTIFICATES TO BE PROVIDE WITH QUOTE

RFQ – REQUEST FOR QUOTATION FOR SAFEGUARDING OF MANHOLES AND BILLING METRES (GOLF VIEW AND KFC METER) SPECIFICATION: 1. SUPPLY AND INSTALLATION OF (5MX5M) 2.4M HIGH CONCRETE PALISADE FENCE MPA25.300MM CONCRETE FOOTING AND FOUNDATION X2 2. SUPPLY AND INSTALLATION OF 2.5M REINFORCED STEEL SECURITY GATE WITH 3 LEVEL LOCKING SYSTEM X2 3. SUPPLY AND INSTALLATION OF 2 500W SOLAR LIGHTS WITH DAY/NIGHT SWITCH X4 MANDATORY REQUIREMENTS: CIDB GRADE 1 (CE)

RFQ – REQUEST FOR QUOTATION FOR SUPPLY OF TOOLS AND EQUIPMENT TO THE FAR WEST MAINTENANCE TEAM MAINTENANCE TOOLS 1. 230 MM LARGE GRINDER (MAKITA/DEWALT OR SIMILAR BRANDS X1 2. 61-PIECE TOOLBOX SET CHROME VANADIUM (GEDORE OR SIMILAR BRAND) X11 3. 17/19 PODGE SPANNERS X7 4. 24/30 PODGE SPANNERS X7 5. 27/36 PODGE SPANNERS X7 6. LARGE (36INCH) PIPE WRENCH HEAVY-DUTY X7 7. MEDIUM(24 INCH) PIPE WRENCH HEAVY DUTY X7 8. SMALL (18 INCH) PIPE WRENCH, HEAVY DUTY X7 9. COMBINATION PLIER X 11 10. HEAVY-DUTY (150 KG LOAD CAPACITY) FOLDABLE LADDERS, BLACK PRO LADDER MULTIFUNCTIONAL (MADE OF ALUMINIUM) X 2 11. HACK SAW (300MM) X 11 12. WOODEN SAW X 2 13. FLOCKING SPANNERS 24MM X7 14. FLOCKING SPANNERS 30MM X7 15. FLOCKING SPANNERS 32MM X7 16. FLOCKING SPANNERS 36MM X7 17. FLOCKING SPANNERS 40MM X7 18. FLOCKING SPANNERS 46MM X7 19. CLAW HAMMER X 2 20. LARGE (12 INCH) HEAVY-DUTY SHIFTING SPANNERS, CHROME VANADIUM X 4 21. SMALL(8 INCH) HEAVY DUTY SHIFTING SPANNERS CHROME VANADIUM X 11 22. RIM WIDTH LARGER (UP TO 600 MM) OUTSIDE CALLIPERS X 2 23. MECHANICAL STEEL VERNIER CALLIPER (UP TO 300 MM) INSTRUMENT TO MEASURE BOLTS X 2 24. HAND HELD GREASE PUMP X 4 25. PICK AND HANDLE X 4 26. DIGGING SPADE X 9 27. SHOVEL X 8 28. 48 INCH PIPE WRENCH X 5

RFQ – REQUEST FOR QUOTATION TO INVITE PROFESSIONAL SERVICE PROVIDERS TO SUBMIT PROPOSALS TO SUPPLY AND INSTALLATION OF NEAR OR REAL TIME WATER TELEMETRY SYSTEM AND DATA TRANSMISSION SYSTEM (4IR TECHNOLOGY) FOR PORTABLE WATER AT PUDIMOE RESERVOIR AND BOGOSING RESERVOIR. REQUIREMENTS: - THE TECHNOLOGY THAT WILL ASSIST IN MONITORING AND REPORTING OF THE FOLLOWING NOT LIMITED PARAMETERS IN REAL TIME. 1. WATER VOLUME 2. RESERVOIRS’ WATER LEVELS 3. LEAKAGE DETECTION 4. APPARENT WATER LOSES MONITORING AND REPORTING 5. WATER FLOWRATE MONITORING AND REPORTING 6. PRESSURE MONITORING AND REPORTING REPORTING AND ACCESSIBILITY 1. THE SYSTEM MUST BE ACCESSIBLE THROUGH MOBILE DEVICE, COMPUTER, LAPTOP IN REAL TIME 23/7

RFQ – REQUEST FOR QUOTATION FOR VAALKOP - SUPPLY AND DELIVERY OF WHEELIE WASTE BINS AND THE SIZE MUST BE 240L AND CHAIN THEM ON THE WALL WITH CHAIN AND HOOKS. 1. RED BIN WITH RECYCLABLE PLASTIC BOTTLES STICKER X 6 2. BLUE BIN WITH RECYCLABLE PAPER STICKER X 6 3. ORANGE BIN WITH RECYCLABLE CANS STICKER X6 4. GREEN BIN WITH RECYCLABLE GLASS STICKER X6 5. GENERAL WASTE BINS IN BLACK COLOUR AND MUST BE LABELLED GENERAL WASTE STICKER AND THE SIZE MUST BE 210L X 6 6. 50L OF RECYCLABLE PAPER BOXES X 3 HEAD OFFICE - SUPPLY AND DELIVERY OF GENERAL WASTE WHEELIE BINS IN BLACK COLOUR AND MUST BE LABELLED GENERAL WASTE STICKER AND THE SIZE MUST BE 240L X 6 BRITS - SUPPLY AND DELIVERY OF 240L WHEELIE BINS THE FOLLOWING: 1.GENERAL WASTE BINS IN BLACK COLOUR AND MUST BE LABELLED GENERAL WASTE STICKER AND THE SIZE MUST BE 25L X 6 2.RED STEEL BIN WITH HAZARDOUS WASTE-BROKEN GLASS STICKER X 2 3.50L OF RECYCLABLE PAPER BOXES X 1 KLIPDRIFT- SUPPLY AND DELIVERY OF WHEELIE WASTE BINS AND THE SIZE MUST BE 240L FOR THE FOLLOWING: 1.RED BIN WITH RECYCLABLE PLASTIC BOTTLES STICKER X 1 2.BLUE BIN WITH RECYCLABLE PAPER STICKER X 1 3.ORANGE BIN WITH RECYCLABLE CANS STICKER X 1 4.GREEN BIN WITH RECYCLABLE GLASS STICKER X1 5.50L OF RECYCLABLE PAPER BOXES X 5

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALLATION OF DN500 PN16 RAW WATER ELECTRO MAG METER SPECIFICATION: SUPPLY AND INSTALLATION SENSOR • NOMINAL DIAMETER 500 MM • PROCESS CONNECTION FLANGED • UNI EN 1092-1 PN16 • MATERIAL CARBON STEEL • LINER EBONITE • MAXIMUM TEMPERATURE80°C • ELECTRODE MATERIAL 316 ST. STEEL • PROTECTION CLASS IP68 • RANGE 0 TO 284 M³/H MIN. 7,100 M³/H MAX. • CABLE LENGTH10 METERS CONVERTOR • DISPLAY GRAPHIC LCD WITH BACK LIGHT. • OUTPUT 4 TO 20 MA • DIGITAL I/O I X DIGITAL INPUT AND 1 X DIGITAL OUTPUT • SUPPLY 100 TO 240 VAC 45/66 HZ • HOUSING NYLON PA6 WITH FIBRE GLASS, IP67 • INSTALLATION SEPARATE FOR WALL MOUNTING • EARTH RINGS, EARTH SPIKE AND GASKETS INCLUDED

RFQ – REQUEST FOR QUOTATION FOR BIO-MONITORING PROGRAMME DEVELOPMENT AND IMPLEMENTATION FOR VAALKOP WATER TREATMENT WORKS 1. BACKGROUND MAGALIES WATER, OPERATING UNDER WATER USE LICENCE NO. 27/2/2/A921/104/1, IS REQUIRED TO IMPLEMENT A BIO-MONITORING PROGRAMME TO ASSESS THE ECOLOGICAL IMPACTS OF EFFLUENT DISCHARGE FROM VAALKOP WATER TREATMENT WORKS INTO THE RECEIVING WATER RESOURCE. THIS RFQ SEEKS QUALIFIED SERVICE PROVIDERS TO DESIGN, IMPLEMENT, AND REPORT ON BIO-MONITORING ACTIVITIES IN COMPLIANCE WITH LICENCE CONDITIONS. 2. SCOPE OF WORK THE APPOINTED SERVICE PROVIDER MUST: 2.1 ESTABLISH A BIO-MONITORING PROGRAMME WITHIN THREE (3) MONTHS OF CONTRACT AWARD. 2.2 CONDUCT WATER QUALITY AND INVERTEBRATE HABITAT ASSESSMENTS AT THREE SITES: 2.2.1 UPSTREAM REFERENCE CONDITION 2.2.2 DISCHARGE POINT 2.2.3 DOWNSTREAM OF THE DISCHARGE POINT 2.3 APPLY THE INVERTEBRATE HABITAT ASSESSMENT SYSTEM (IHAS) AND SOUTH AFRICAN SCORING SYSTEM (SASS) METHODOLOGIES. 2.4 UNDERTAKE SEASONAL SAMPLING (SUMMER AND WINTER). 2.5 COMPARE RESULTS AGAINST REFERENCE CONDITIONS WITHIN THE SAME ECO-REGION. 2.6 PREPARE BIO-MONITORING REPORTS HIGHLIGHTING IMPACTS, CHANGES, DETERIORATION, OR IMPROVEMENTS IN AQUATIC ECOSYSTEM HEALTH. 2.7 CONDUCT QUARTERLY TOXICITY MONITORING OF FINAL EFFLUENT USING THE DEPARTMENT’S DIRECT ESTIMATION OF ECOLOGICAL EFFECT POTENTIAL (DEEEP) APPROACH

”RFQ

RFQ – REQUEST FOR QUOTATION FOR CHEMICAL VERIFICATIONS LIME (5 SAMPLES) AND POLY (13 SAMPLES): TOTAL ANTIMONY TOTAL ARSENIC TOTAL SELENIUM TOTAL URANIUM TOTAL IRON TOTAL MANGANESE TOTAL BARIUM TOTAL BORON TOTAL CADMIUM. TOTAL CHROMIUM TOTAL COPPER TOTAL NICKEL TOTAL LEAD TOTAL ALUMINUM SPECIFIC GRAVITY PH DENSITY %SOLIDS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF WAFER CHECK VALVE 1. WAFER CHECK VALVE 50MM 12 2. AIR RELEASE VALVE 25DN 25 PN SCREWED 10 3. AIR RELEASE VALVE 50DN 25PN SCREWED

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF GATE VALVE 1. GATE VALVE DN350 PN16 3 2. GATE VALVE DN350 PN25 3 3. GATE VALVE WEDGE PN25 80MM

RFQ – REQUEST FOR QUOTATION FOR DRILLING, TESTING, AND EQUIPPING OF A BOREHOLE WITH PUMP HOUSE, VALVES, AND FLOW METER FOR 2 X BOREHOLES AT MMUKUBYANE AND CYFERSKUIL VILLAGES IN MORETELE LM, AND INSTALLATION OF A WATER TREATMENT FACILITY TO ACCEPTABLE STANDARDS

RFQ – REQUEST FOR QUOTATION FOR DRILLING, TESTING, AND EQUIPPING OF A BOREHOLE WITH PUMP HOUSE, VALVES, AND FLOW METER AT ROEDTAN IN MODIMOLLE-MOOKGOPONG LM

RFQ – REQUEST FOR QUOTATION FOR AIR COMPRESSOR PREVENTIVE MAINTENANCE AND SERVICE THE CONTRACTOR SHALL CARRY OUT A FULL SERVICE AND INSPECTION OF AIR COMPRESSOR TO ENSURE SAFE, RELIABLE AND EFFICIENT OPERATION IN ACCORDANCE WITH THE MANUFACTURE RECOMMENDATIONS AND SITE SAFETY THIS SERVICE WILL BE FOR TWO AIR COMPRESSOR FOR BLOEMHOF AND CHRISTIANA MANDATORY REQUIREMENTS: - 1. CIDB GRADING LEVEL 1 MECHANICAL 2. SITE VISIT COMPULSORY, FRIDAY 20 MARCH 2026 @11H30 PLACE: BLOEMHOF PLANT CONTACT PERSON MR. THOMAS RIBOMBO 069 019 6240

RFQ – REQUEST FOR QUOTATION FOR AIR COMPRESSOR PREVENTIVE MAINTENANCE AND SERVICE THE CONTRACTOR SHALL CARRY OUT A FULL SERVICE AND INSPECTION OF AIR COMPRESSOR TO ENSURE SAFE, RELIABLE AND EFFICIENT OPERATION IN ACCORDANCE WITH THE MANUFACTURE RECOMMENDATIONS AND SITE SAFETY THIS SERVICE WILL BE FOR TWO AIR COMPRESSOR FOR PUDIMOE PLANT MODULE 1 & MODULE 3 MANDATORY REQUIREMENTS: - 1. CIDB GRADING LEVEL 1 MECHANICAL 2. SITE VISIT COMPULSORY, FRIDAY 20 MARCH 2026 @08H00 PLACE: PUDIMOE PLANT CONTACT PERSON MR. THOMAS RIBOMBO 069 019 6240

RFQ – REQUEST FOR QUOTATION FOR MAGALIES WATER HARTBEESPOORT DAM REHABILITATION PROJECT 2025/26 ANNUAL REPORT

RFQ – REQUEST FOR QUOTATION TO REQUEST FOR A COMPANY TO DEVELOP THE SHE LEGAL REGISTER WITH ANNUAL SUBSCRIPTION FOR A PERIOD OF 3 YEARS. THE REGISTER MUST BE UPDATED MONTHLY AND ALERTS SENT REGULARLY. THE REGISTER MUST BE ABLE TO LINK TO OUR ASPECT AND IMPACTS AS WELL AS HAZARDS AND RISKS. A SOFT COPY MUST BE PROVIDED ON AN ANNUAL BASIS. ACCESS MUST BE GRANTED TO 6 USERS. REQUIREMENTS 1. LEAD PERSONNEL 1. MUST HAVE QUALIFICATIONS IN HEALTH AND SAFETY NQF LEVEL 7 OR ABOVE 2. PERSONNEL 2. MUST HAVE QUALIFICATIONS IN ENVIRONMENTAL LAW NQF LEVEL 7 OR ABOVE NB- ONE PERSONNEL CAN BE IN POSSESSION OF THE TWO QUALIFICATIONS. 3. THE COMPANY MUST HAVE 5 YEARS’ EXPERIENCE IN DEVELOPING AND MANAGEMENT OF A LEGAL REGISTER. ATTACH TRACEABLE REFERENCE LETTERS AND PURCHASE ORDERS/APPOINTMENT LETTERS. (REFERENCE/PURCHASE ORDERS/APPOINTMENT LETTERS WILL BE VERIFIED

RFQ – REQUEST FOR QUOTATION TO PERFORM ULTRASONIC TEST AND RADIOGRAPHIC TESTING (RT) ON ALL GOOSENECK PIPE WELDS TO DETECT SUBSURFACE DEFECTS LIKE CRACKS, PORES, OR INCOMPLETE FUSION AS PER APPLICABLE STANDARDS PERFORM ULTRASONIC TEST ON ALL GOOSENECK WALL TO DETERMINE WALL THICKNESS OF THE GOOSE NECK AS PER APPLICABLE STANDARDS. APPLICABLE STANDARDS 1. ISO 17636: NON-DESTRUCTIVE TESTING OF WELDS—RADIOGRAPHIC TESTING. 2. ISO 9712: 3. ASME SECTION V: NON-DESTRUCTIVE EXAMINATION ASME SECTION VIII, DIVISION 1 (UW-11 & UW-51) HIGH LIFT PUMP STATION 3 (PUMP 1 – 5 GOOSENECKS) PERFORM HYDROSTATIC PRESSURE TESTING ON ALL GOOSENECKS TO 1.3 X DESIGN WORKING PRESSURE, TO DETECT LEAKS, STRUCTURAL WEAKNESSES, OR FLAWS LIKE POOR WELDS, ENSURING THE SYSTEM'S INTEGRITY BEFORE SERVICE AS PER APPLICABLE STANDARDS (FLANGE RATINGS PN40) X 5 APPLICABLE STANDARDS 1. PRESSURE EQUIPMENT REGULATIONS (PER), 2009. OCCUPATIONAL HEALTH AND SAFETY ACT, 1993 (ACT NO. 85 OF 1993). 2. SANS 347 SOUTH AFRICAN NATIONAL STANDARD FOR PRESSURE EQUIPMENT SAFETY AND CONFORMITY DURATION & MONITORING: • HOLD FULL TEST PRESSURE FOR AT LEAST 2 HOURS • RECORD PRESSURE DROPS (IDEALLY EVERY 15 MINS) AND NOTE WATER NEEDED TO MAINTAIN PRESSURE

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALLATION OF HYACINTH BARRIER AT VAALKOP DAM INSTALL FIXED ANCHORS ON THE DAM WALL X 2 INSTALL GRAPPLE ANCHORS 6 X 100KG INSIDE WITH HOOKS ANCHORS MUST BE 30 METER OR MORE INSIDE THE WATER ANCHORS POINTS TO BE INSTALLED MUST WITHSTAND 80 METER PER HECTARE (FORCE) INSTALL 100 METERS INTERLOCKING (260KG ON EACH BUOYANCY) FLOATING INTERLOCKING HYACINTH BARRIER. THE FINE MESH NET (NON-CORROSIVE) OF 500 MM MUST BE SELF-SINKING WITH 3MM OR LESS HOLES. THE BARRIER TO BE WATER HEIGHT AND FLEXIBLE TO ACCOMMODATE A 10-METER VERTICAL WATER DROP WITHOUT ADJUSTMENT DURING INSTALLATION THE TOTAL LENGTH OF THE BARRIER MUST BE AT LEAST 320 METERS SERVICE PROVIDER TO ISSUE AT LEAST 1 YEAR WARRANTY AFTER INSTALLATION COMPANY EXPERIENCE: PROVIDE 3 COMPANY EXPERIENCE INVOICES OR COMPLETION CERTIFICATES OF SIMILAR WORK COMPLETED DIVER CERTIFICATE, MEDICAL CERTIFICATE AND DIVING EXPERIENCE. HIGH LIFT PUMP 3 (PUMP 1 – 5)

RFQ – REQUEST FOR QUOTATION FOR FAR WEST MEDIA CAMPAIGN WATER MONTH

RFQ – REQUEST FOR QUOTATION FOR SERVICE, MAINTENANCE AND REPAIR OF 10 X SHARP BP-50C31 PRINTERS I. MAINTENANCE & SUPPORT X12 MONTHS - PREVENTIVE MAINTENANCE - BREAKDOWN REPAIRS AND REPLACEMENT OF FAULTY PARTS. - LABOUR - TECHNICAL SUPPORT - 48-HOUR RESPONSE SLA N.B COUNTERFEIT PARTS WILL NOT BE ACCEPTED. II. CONSUMABLES - SUPPLY AND REPLACEMENT OF TONERS (BLACK, CYAN, MAGENTA, YELLOW). N.B COUNTERFEIT TONERS WILL NOT BE ACCEPTED. N.B CONSUMABLES MUST BE COURIERED TO RUSTENBURG HEAD OFFICE TO MINIMISE TRAVELLING COSTS III. REPAIR OF EXISTING FAULTS ON PRINTERS (PRIOR CONTRACT). X3 IV. TRAVELLING COSTS - TRAVEL CHARGES APPLY ONLY WHEN ON-SITE ATTENDANCE IS REQUIRED. SITES: BRITS X 1, CULLINAN X 1, KLIPDRIFT X 1, MMABATHO X 1, RUSTENBURG X 3, TAUNG X 1, VAALKOP X 1, WALMANSDAL X 1

RFQ – REQUEST FOR QUOTATION FOR THE DEVELOPMENT OF THE KNOWLEDGE MANAGEMENT (KM) PORTAL ON SHAREPOINT, USING MICROSOFT APPLICATION OFFICE 365. THE KM PORTAL SHALL PROVIDE A CENTRALIZED DIGITAL PLATFORM FOR THE ORGANIZATION TO CAPTURE, STORE, MANAGE AND SHARE CRITICAL KNOWLEDGE AND INFORMATION. THE PORTAL WILL SERVE AS A SINGLE POINT OF ACCESS TO LESSONS LEARNED, BEST PRACTICES, AND EXPERT INSIGHTS, ENABLING EMPLOYEES TO EASILY RETRIEVE AND CONTRIBUTE KNOWLEDGE. BY IMPLEMENTING THE KM PORTAL, THE KNOWLEDGE MANAGEMENT TEAM AIMS TO: • IMPROVE OPERATIONAL EFFICIENCY THROUGH QUICK ACCESS TO RELIABLE INFORMATION. • ENHANCE COLLABORATION AND KNOWLEDGE SHARING ACROSS DEPARTMENTS AND TEAMS. • PRESERVE INSTITUTIONAL KNOWLEDGE AND REDUCE THE RISK OF KNOWLEDGE LOSS DUE TO STAFF TURNOVER. • SUPPORT INFORMED DECISION MAKING WITH UP-TO-DATE AND VERIFIED KNOWLEDGE RESOURCES. • PROMOTE INNOVATION AND CONTINUOUS LEARNING WITHIN THE ORGANIZATIONKIND REGARDS

RFQ – REQUEST FOR QUOTATION FOR FILTER REFURBISHMENT RFQ THE SERVICE PROVIDER TO BE APPOINTED TO CARRY OUT FILTER REPLENISHMENT PROJECT ON PUDIMOE MODULE 1 SANDFILTERS AS PER THE FOLLOWING SPECIFICATIONS: - SCOPE OF WORK: REPLACE MEDIA AS PER ATTACHED SPECIFICATIONS: LAYER MEDIA SIZE DEPTH 1ST LAYER FILTERING MEDIA 0.6 MM – 1.2 MM 700 MM 2ND LAYER COARSE MEDIA 2.36 MM – 4.75 MM 150 MM 3RD LAYER PEBBLE (GRAVEL MEDIA) 6 MM – 13 MM 150 MM. • REMOVE OLD FILTER SAND AND CLEAN THE FILTER; • CLEAN THE FALSE FLOOR; • REPLACE ALL THE BROKEN/DEFECTIVE FILTER NOZZELS; THE SERVICE PROVIDER TO COMMISSION THE SAND FILTERS, FOLLOWED BY THE HANDOVER OF THE PROJECT UPON COMPLETION

RFQ – REQUEST FOR QUOTATION FOR SERVICE GENERATOR RFQ SERVICE OF DIESEL GENERATOR AT PUDIMOE PLANT SCOPE OF WORK: PERFORM ANNUAL GENERATOR SERVICE ON A 1000 KVA DIESEL POWERED GENERATOR X2 MANDATORY REQUIREMENTS: 1. CIDB GRADE 1 MECHANICAL 2. QUALIFICATION OF PERSONNEL: DIESEL MECHANICAL OR ELECTRICIAN FOR SERVICE TECHNICIAN 3. EXPERIENCE OF PERSONNEL: MUST HAVE MINIMUM 3 YEARS MECHANICAL OR ELECTRICAL EXPERIENCE, WORKING WITH DIESEL ENGINES OR HEAVY EQUIPMENT. 4. COMPULSORY SITE BRIEFING: THURSDAY 19 MARCH @9H00 AT PUDIMOE PLANT

RFQ – REQUEST FOR QUOTATION FOR FILTER REFURBISHMENT RFQ THE SERVICE PROVIDER TO BE APPOINTED TO CARRY OUT FILTER REPLENISHMENT PROJECT ON PUDIMOE MODULE 1 SANDFILTERS AS PER THE FOLLOWING SPECIFICATIONS: - SCOPE OF WORK: REPLACE MEDIA AS PER ATTACHED SPECIFICATIONS: LAYER MEDIA SIZE DEPTH 1ST LAYER FILTERING MEDIA 0.6 MM – 1.2 MM 700 MM 2ND LAYER COARSE MEDIA 2.36 MM – 4.75 MM 150 MM 3RD LAYER PEBBLE (GRAVEL MEDIA) 6 MM – 13 MM 150 MM. • REMOVE OLD FILTER SAND AND CLEAN THE FILTER; • CLEAN THE FALSE FLOOR; • REPLACE ALL THE BROKEN/DEFECTIVE FILTER NOZZELS; THE SERVICE PROVIDER TO COMMISSION THE SAND FILTERS, FOLLOWED BY THE HANDOVER OF THE PROJECT UPON COMPLETION.

RFQ – REQUEST FOR QUOTATION FOR 1. ALIEN INVASIVE PLANTS TREATMENT AND REMOVAL AT RAW WATER, SLUDGE DAM, SALVAGE YARD AND PLANT AT VAALKOP WATER TREATMENT PLANT. SUBMIT A DETAILED REPORT WITH FINDINGS AND RECOMMENDATIONS. 2. ALIEN INVASIVE PLANTS TREATMENT AND REMOVAL AT KLIPDRIFT, WALLMANSTHAL AND CULLINAN WATER TREATMENT PLANTS. SUBMIT A DETAILED REPORT WITH FINDINGS AND RECOMMENDATIONS. THE REMOVAL MUST BE IN 2 YEARS AND REMOVED TWICE IN YEAR. THE COMPANY MUST HAVE MORE THAN 3 YEARS’ EXPERIENCE IN ALIEN SPECIES REMOVAL. ATTACH PROOF TO QUOTE. PROVIDE PROOF OF REGISTRATION AS PEST CONTROL OPERATOR WITH THE DEPARTMENT OF AGRICULTURE FORESTRY AND FISHERIES. ATTACH TO QUOTE. THE COMPANY MUST PROVIDE A METHOD STATEMENT AND A SHE FILE PRIOR COMMENCEMENT OF WORK. COMPLY WIWITH RELEVANT SHE LEGISLATION. ALIEN INVASIVE PLANTS THAT WERE PREVIOUSLY IDENTIFIED ON SITE. 1.BLUE GUM 2.CASTOR OIL 3.GIANT REED 4.MULBERRY 5.LANTANA 6.PRICKLY PEAR 7.SISAL 8.SERINGA 9.VELVET ASH 10.BLACK WATTLE 11.SORREL REMEX 12.POPLARS 13.MEXICAN POPPY 14.SESSILE JOY WEED. 15.FOUNTAIN GRASS

RFQ – REQUEST FOR QUOTATION FOR SALE OF FERROUS AND NON- FERROUS METALS FOR MAGALIES WATER IN FAR WEST, MAFIKENG

RFQ – REQUEST FOR QUOTATION FOR SUPPLY STANDARDS AND CALIBRATIONS LAB EQUIPMENT 1. SUPPLY 1X CONDUCTIVITY STANDARD 2. PERFORM CALIBRATION DR3900 3. PERFORM SERVICE DR3900 4. PERFORM CALIBRATION HQ440D PH 5. PERFORM CALIBRATION HQ440D CONDUCTIVITY 6. SUPPLY H92456-00 DISPLAY WINDOW HQ440D 7. SUPPLY H92453-00 HOUSING TOP HQD BENCHTOP 8. PERFORM CALIBRATION TL2300 9. LAMP REPLACEMENT TL2300

RFQ – REQUEST FOR QUOTATION FOR REQUEST FOR A COMPANY TO DEVELOP THE SHE LEGAL REGISTER WITH ANNUAL SUBSCRIPTION FOR A PERIOD OF 3 YEARS. THE REGISTER MUST BE UPDATED MONTHLY AND ALERTS SENT REGULARLY. THE REGISTER MUST BE ABLE TO LINK TO OUR ASPECT AND IMPACTS AS WELL AS HAZARDS AND RISKS. A SOFT COPY MUST BE PROVIDED ON AN ANNUAL BASIS. ACCESS MUST BE GRANTED TO 6 USERS. REQUIREMENTS 1. LEAD PERSONNEL 1. MUST HAVE QUALIFICATIONS IN HEALTH AND SAFETY NQF LEVEL 7 OR ABOVE 2. PERSONNEL 2. MUST HAVE QUALIFICATIONS IN ENVIRONMENTAL LAW NQF LEVEL 7 OR ABOVE NB- ONE PERSONNEL CAN BE IN POSSESSION OF THE TWO QUALIFICATIONS. 3. THE COMPANY MUST HAVE 5 YEARS’ EXPERIENCE IN DEVELOPING AND MANAGEMENT OF A LEGAL REGISTER. ATTACH TRACEABLE REFERENCE LETTERS AND PURCHASE ORDERS/APPOINTMENT LETTERS. (REFERENCE/PURCHASE ORDERS/APPOINTMENT LETTERS WILL BE VERIFIED.)

”RFQ

RFQ – REQUEST FOR QUOTATION TO HIRE MOBILE TOILETS FOR MOROKWENG OFFICE. 1 FOR FEMALES AND 1 FOR MALES ON 1 TRAILER RENTAL PERIOD: 3 MONTHS

RFQ – REQUEST FOR QUOTATION FOR PRINT AND DELIVER BOOKS FOR ALL SITES AT VAALKOP PLANT. ALL BOOKS MUST HAVE THE FRONT AND BACK COVER. ALL BOOKS MUST HAVE THE NAME OF THE BOOK DISPLAYED ON THE OUTSIDE. FOR EACH BOOK, EACH PAGE MUST HAVE A DUPLICATE WHICH CAN BE EASILY TEARED OFF. PRINTING OF VARIETY OF SAFETY, HEALTH AND ENVIRONMENTAL POSTERS AND STICKERS. A SAMPLE / TEMPLATE WILL BE PROVIDED FOR EACH FORM. ALL BOOKS MUST BE AN A 4 SIZE. SEE BELOW BOOKS TO BE PRINTED: INCIDENT REPORTING BOOKS PRINTING OF 50 INCIDENT REPORTING FORMS. QUANTITY OF BOOKS- 20. JOB TASK OBSERVATION (JTO) BOOKS PRINTING OF 100 JTO FORMS. QUANTITY OF BOOKS- 100. RISK ASSESSMENT PRINTING OF 100 RISK ASSESSMENT FORMS. QUANTITY OF BOOKS- 100. SHE INDUCTION BOOKS PRINTING OF 100 SHE INDUCTION FORMS. QUANTITY OF BOOKS- 50. INCAR BOOKS PRINTING OF 100 INCAR FORMS. QUANTITY OF BOOKS- 50. WORK PERMIT BOOKS PRINTING OF 100 WORK PERMIT FORMS. QUANTITY OF BOOKS- 50. TOOLBOX TALK BOOKS PRINTING OF 100 TOOLBOX TALK FORMS. QUANTITY OF BOOKS- 50. VARIETY OF SAFETY, HEALTH AND ENVIRONMENTAL POSTER (OHS ACT, SAFETY RULES, SAFETY INSTRUCTIONS, AWARENESS). QUANTITY IS 200. VARIETY OF SAFETY, HEALTH AND ENVIRONMENTAL STICKERS. QUANTITY IS 200

RFQ – REQUEST FOR QUOTATION FOR CONDUCT ASBESTOS RISK ASSESSMENT AND DEVELOP AN ASBESTOS INVENTORY AT SOUTH WEST REGION (GREATER TAUNG, LEEUDORINGSTAD, GANYESA AND MOROKWENG) AND FAR WEST REGION (MAFIKENG WTW, LEHURUTSHE OFFICE, MOLATEDI DAM. THE COMPANY MUST HAVE EXPERIENCE IN CONDUCTING ASBESTOS RISK ASSESSMENTS. ATTACH PROOF WITH THE QUOTATION. THE ASSESSMENT MUST BE CONDUCTED BY COMPETENT ASSESSORS WITH EXPERIENCE IN ASBESTOS RISK ASSESSMENTS AND PROOF MUST BE ATTACHED. THE RISK ASSESSMENT MUST BE CONDUCTED AS PER THE UPDATED ASBESTOS ABATEMENT REGULATIONS. THE COMPANY MUST PROVIDE A DETAILED REPORT RISK REGISTER TOGETHER WITH A COMPREHENSIVE REPORT AS PER REGULATION 5 AND RECOMMENDATIONS AFTER CONDUCTING THE RISK ASSESSMENTS. COMPILE AN ASBESTOS MANAGEMENT PLAN AS PER REGULATION 6 OF THE ASBESTOS ABATEMENT REGULATIONS. THE COMPANY MUST PROVIDE A DETAILED REPORT ON THE ASBESTOS MANAGEMENT PLAN ADDRESSING ALL THE REQUIREMENTS WITHIN REGULATION 6 OF THE ASBESTOS ABATEMENT REGULATIONS AS WELL AS RECOMMENDATIONS TO ADDRESS THE GAPS IDENTIFIED

RFQ – REQUEST FOR QUOTATION FOR 10 X SCRIPTED 10-MINUTE SCRIPTED RADIO INTERVIEWS IN SETSWANA AND OR ENGLISH ON AT LEAST FOUR OF THE FOLLOWING RADIO STATIONS: MAHIKENG FM, MMABATHO FM, KOPANONG FM, BOKONE BOPHIRIMA FM. ADVERTISING 4 X 30" RECORDED ADVERTS AND OR SCRIPTED LIVE READS TO BE RUN DURING THE DAY-TIME WEEKDAY RADIO SHOWS 4 X 500 WORDED NEWSPAPER ARTICLES/ADVERTORIALS/INTERVIEWS IN IN AT LEAST FIVE THE FOLLOWING NEWSPAPERS: THE MAIL, STELLANDER, TAUNG DAILY NEWS, THE VRYBURG INDEPENDENT POST, NORTH WEST INSIDER, MMEGADIKGANG

RFQ – REQUEST FOR QUOTATION TO ASSESS, QUOTE AND REPAIR GANYESA STORES ROOF ACCORDING TO SPECIFICATIONS BELOW: - * STRIP STORES' ROOF HALFWAY, REPAIR OR REPLACE THEN THE 2ND HALF. * REPLACE WOODEN TIMBER WITH IBR SHEETS GALVANISED. * REPLACE STORE OFFICE AND STATIONERY OFFICE CEILING WITH WATERPROOF CEILING. SHE - SAFETY FILE FOR COMPLIANCE BEFORE THE WORK COMMENCED

RFQ – REQUEST FOR QUOTATION TO DO MINOR REFURBISHMENT AT GANYESA OFFICES, * REPLACE WORN OUT WINDOWS BLINDS, SIZES TO BE CONFIRMED AT BRIEFING. * REPAIR LEAKING ROOF IN INSPECTOR OFFICE * REPLACE VERANDA NET WITH CHANNEL IRONS AND IBR SHEETS 2 X 4M AT MAIN OFFICE AND CASH OFFICE ENTRANCES. * REPLACE DAMAGED BATHROOM FLOOR AT CASH OFFICE

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALLATION OF HYACINTH BARRIER AT VAALKOP DAM INSTALL FIXED ANCHORS ON THE DAM WALL X 2 INSTALL GRAPPLE ANCHORS 6 X 100KG INSIDE WITH HOOKS ANCHORS MUST BE 30 METER OR MORE INSIDE THE WATER ANCHORS POINTS TO BE INSTALLED MUST WITHSTAND 80 METER PER HECTARE (FORCE) INSTALL 100 METERS INTERLOCKING (260KG ON EACH BUOYANCY) FLOATING INTERLOCKING HYACINTH BARRIER. THE FINE MESH NET (NON-CORROSIVE) OF 500 MM MUST BE SELF-SINKING WITH 3MM OR LESS HOLES. THE BARRIER TO BE WATER HEIGHT AND FLEXIBLE TO ACCOMMODATE A 10-METER VERTICAL WATER DROP WITHOUT ADJUSTMENT DURING INSTALLATION THE TOTAL LENGTH OF THE BARRIER MUST BE AT LEAST 320 METERS SERVICE PROVIDER TO ISSUE AT LEAST 1 YEAR WARRANTY AFTER INSTALLATION COMPANY EXPERIENCE: PROVIDE 3 COMPANY EXPERIENCE INVOICES OR COMPLETION CERTIFICATES OF SIMILAR WORK COMPLETED DIVER CERTIFICATE, MEDICAL CERTIFICATE AND DIVING EXPERIENCE

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALLATION OF HYACINTH BARRIER AT VAALKOP DAM INSTALL FIXED ANCHORS ON THE DAM WALL X 2 INSTALL GRAPPLE ANCHORS 6 X 100KG INSIDE WITH HOOKS ANCHORS MUST BE 30 METER OR MORE INSIDE THE WATER ANCHORS POINTS TO BE INSTALLED MUST WITHSTAND 80 METER PER HECTARE (FORCE) INSTALL 100 METERS INTERLOCKING (260KG ON EACH BUOYANCY) FLOATING INTERLOCKING HYACINTH BARRIER. THE FINE MESH NET (NON-CORROSIVE) OF 500 MM MUST BE SELF-SINKING WITH 3MM OR LESS HOLES. THE BARRIER TO BE WATER HEIGHT AND FLEXIBLE TO ACCOMMODATE A 10-METER VERTICAL WATER DROP WITHOUT ADJUSTMENT DURING INSTALLATION THE TOTAL LENGTH OF THE BARRIER MUST BE AT LEAST 320 METERS SERVICE PROVIDER TO ISSUE AT LEAST 1 YEAR WARRANTY AFTER INSTALLATION COMPANY EXPERIENCE: PROVIDE 3 COMPANY EXPERIENCE INVOICES OR COMPLETION CERTIFICATES OF SIMILAR WORK COMPLETED DIVER CERTIFICATE, MEDICAL CERTIFICATE AND DIVING EXPERIENCE

RFQ – REQUEST FOR QUOTATION FOR CLEANING OF THE DRYING BEDS 5X REPEATS CLEANING OF 14 DRY BEDS, HIRE OF LABOUR AND WORKING SUPERVISOR - 5X REPAIR OF DAMAGED WALL - SUM WATERPROOFING INSIDE THE BEDS - SUM

RFQ – REQUEST FOR QUOTATION FOR CLEANING OF KLIPDRIFT RECOVERY DAMS 3 X REPEAT HIRE OF LOCAL LABOUR AND A WORKING SUPERVISOR FOR CLEANING - X3 HIRE OF VACUUM PUMP/PUMP TO ASSIST WITH THE CLEANING - X3 PROCURE SLUDGE GEOTEXTILE MATERIAL FOR THE COLLECTION OF SLUDGE - 4X CONNECTION OF PUMP TO THE SLUDGE GEOTEXTILE MATERIAL - SUM NOTE MAGALIES WATER WILL ASSIST WITH A PUMP AND PUMP OF THE WATER TO REDUCE A COMPULSORY SITE BRIEFING TO BE HELD 10 MARCH 2026 11:00 KLIPDRIFT WATER TREATMENT PLANT. ONLY LOCAL SOUTH AFRICAN LABOUR WILL BE USED FOR THE WORK A FULL HEALTH AND SAFETY DOCUMENT WILL BE REQUIRED BEFORE SITE HANDOVER

RFQ – REQUEST FOR QUOTATION FOR SUPPLY, DELIVERY, AND INSTALLATION OF A NEW ROTARY SCREW COMPRESSOR. REPLACEMENT OF THE EXISTING AIR COMPRESSOR AT WALLMANNSTHAL WTW WITH A NEW, ENERGY EFFICIENT, AND RELIABLE UNIT TO ENSURE CONTINUOUS AIR SUPPLY FOR PLANT INSTRUMENTATION, PNEUMATIC ACTUATORS, AND PROCESS OPERATIONS. THE NEW COMPRESSOR SHALL BE INSTALLED, TESTED, AND COMMISSIONED AS A FULLY FUNCTIONAL REPLACEMENT FOR THE EXISTING SYSTEM. SCOPE OF WORK; SITE ASSESSMENT AND VERIFICATION OF THE EXISTING COMPRESSOR INSTALLATION. DISCONNECTION AND SAFE REMOVAL OF THE OLD COMPRESSOR. SUPPLY AND DELIVERY OF A NEW, FACTORY-TESTED AIR COMPRESSOR SYSTEM WITH MATCHING PERFORMANCE. INSTALLATION OF THE NEW COMPRESSOR ON THE EXISTING OR NEW FOUNDATION. CONNECTION TO THE EXISTING COMPRESSED AIR NETWORK AND ELECTRICAL POWER SUPPLY. INTEGRATION OF CONTROL AND SAFETY SYSTEM. TESTING, COMMISSIONING, AND PERFORMANCE VERIFICATION. TRAINING OF THE OPERATORS AND HANDOVER DOCUMENTATION. UPGRADE THE AIR PIPE NETWORK AND INSTALL WATER TRAPS. SUPPLY AND DELIVER X 6 254 PCE 4 DRAWER 660X310X380 TOOLBOX SET. COMPRESSOR SPEC: ROTARY SCREW COMPRESSOR. POWER RATING 15KW. WORKING PRESSURE 6-10 BAR. DUTY CYCLE 100% CONTINUOUS OPERATION COOLING TYPE AIR COOLED. COMPRESSOR CONFIGURATION FULLY PACKAGED UNIT WITH INTEGRATED AIR DRYER AND FILTERS. RECEIVER TANK 500L HORIZONTAL. CONTROL SYSTEM AUTOMATIC LOAD/UNLOAD CONTROL WITH PRESSURE REGULATION. PROTECTION OVERLOAD, OVER TEMPERATURE, HIGH PRESSURE SHUTDOWN, PHASE FAILURE, LOW OIL PRESSURE. THE SERVICE PROVIDER SHALL PERFORM: MECH ELEC PRE-COMMISSION CHECKS, LEAK AND VIBRATION INSPECTION. THE FOLLOWING DOCS MUST BE SUBMITTED: MANUFACTURER'S DATA SHEET AND PERFORMANCE CURVES. OPERATION AND MAINTENANCE MANUALS. ELEC AND MECH

RFQ – REQUEST FOR QUOTATION FOR RESTORATION OF BLOWER TO OPTIMAL CONDITION. RESTORATION OF BLOWER TO OPTIMAL CONDITION BY PERFORMING A COMPREHENSIVE MECHANICAL AND ELECTRICAL OVERHAUL, ENSURING RELIABLE PERFORMANCE, ENERGY EFFICIENCY AND COMPLY WITH OPERATIONAL STANDARDS. DISASSEMBLE THE BLOWER HOUSING, BEARINGS AND DRIVE COMPONENTS. CHECK FOR WEAR, CORROSION, CRACKS AND ALIGNMENT ISSUES. REPLACE ALL WORN OR DAMAGED PARTS, INCLUDING BEARINGS, SEALS AND GASKETS , COUPLING AND GEAR DRIVES OR A COMPLETE AIR-END. CLEAN THE INTERNAL COMPONENTS AND REMOVE OIL RESIDUE OR CORROSION. REASSEMBLE WITH PRECISION TORQUE AND ALIGNMNET CHECKS. VERIFICATION OF CONTROL PANEL FUNCTIONALITY; START/STOP SEQUENCE, OVERLOAD PROTECTION, VARIABLE FREQUENCY DRIVE. PERFORMANCE TESTING; TEST UNDERLOAD TO VERIFY AIRFLOW, PRESSURE, AND NOISE LEVELS. EFFICIENCY ASSESSMENT COMPARED TO MANUFACTURER SPECS. LEAK DETECTION AND CORRECTION IN AIR DELIVERY SYSTEM. DELIVERABLES: FULLY OVERHAULED AND TESTED BLOWER. INSPECTION AND TEST REPORT. LIST OF REPLACED COMPONENTS. CONTRACTOR REQUIREMENT: MUST PROVIDE AT LEAST 2 REFERENCE LETTER FOR SIMILAR JOB

RFQ – REQUEST FOR QUOTATION FOR BULK WATER METER MEISTREAM 50MM 10 BULK WATER METER MEISTREAM 80MM 10 WATER METERS MEISTREAM 150 5 BULK WATER METER MEISTREAM 200MM 5 BULK WATER METER MEISTREAM 250M

RFQ – REQUEST FOR QUOTATION FOR TRANSMITTER MX 2034

RFQ – REQUEST FOR QUOTATION FOR OVERHAUL OF PRE AND POST CHLORINE CRANE. SERVICE PROVIDER MUST ASSESS, SERVICE AND ENSURE THE SAFE AND EFFICIENT OPERATION OF THE EXISTING MONORAIL ELECTRIC HOIST. CONDUCT A FULL MECHANICAL AND ELECTRICAL ASSESSMENT OF THE MONORAIL ELECTRIC HOIST. INSPECT ALL ELECTRICAL COMPONENTS AND CONNECTIONS AND RECTIFY ANY DEFECT FOUND. LUBRICATE ALL MOVING PARTS. VERIFY THAT ALL SAFETY DEVICES, INCLUDING LIMIT SWITCHES, BRAKES, AND RELATED SAFETY FEATURES, ARE FULLY FUNCTIONAL AND COMPLIANT WITH SAFETY STANDARDS. INSPECT THE LOAD CHAIN FOR WEAR, CORROSION, OR DAMAGE, AND REPLACE IF IT DOES NOT MEET SAFETY OR OPERATIONAL REQUIREMENTS. SUPPLY AND INSTALL A SUITABLE ELECTRIC TROLLEY COMPLETE WITH REMOTE CONTROL. PERFORM FUNCTIONAL TESTING AFTER SERVICING AND INSTALLATION TO CONFIRM CORRECT OPERATION. PERFORM A LOAD TEST AND ISSUE A LOAD TEST CERTIFICATE. SERVICE PROVIDER MUST PROVIDE: DETAILED INSPECTION REPORT AND SERVICE REPORT. LOAD TEST CERTIFICATE. MAINTENANCE CHECKLIST COMPLETED. SERVICE PROVIDER MUST: BE REGISTERED AND COMPETENT TO WORK ON LIFTING MACHINERY. PROVIDE PROOF OF COIDA AND RELEVANT EXPERIENCE WITH HOIST AND LIFTING EQUIPMENT. SUBMIT A SAFETY FILE WITHIN 7 DAYS OF RECEIVING THE PO. EQUIPMENT DETAILS: MAKE; ELEPHANT. TYPE; MONORAIL ELECTRIC HOIST. CAPACITY;3 TON.

RFQ – REQUEST FOR QUOTATION FOR COC FOR CHLORINE DOSING SYSTEM. ASSESSMENT, REPAIR, AND ISSUING OF CERTIFICATE OF COMPLIANCE(COC) FOR CHLORINE GAS INSTALLATION AT CULLINAN WTW, WALLMANNSTHAL WTW AND KLIPDRIFT WTW. SCOPE: CONDUCT A COMPREHENSIVE INSPECTION AND ASSESSMENT OF THE EXISTING CHLORINE GAS INSTALLATION, INCLUDING LIQUID TRAPS, MAMIFOLDS, INJECTORS AND SAFETY SYSTEM. IDENTIFY AND REPORT ANY DEFECTS, LEAKS, NON-COMPLIANCES, OR DEVIATION FROM SANS STANDARDS AND OHS REQUIREMENTS. CARRY OUT NECESSARY REPAIRS OR REPLACEMENTS TO ENSURE THE INSTALLATION COMPLIES WITH STATUTORY AND MANUFACTURER REQUIREMENTS. PERFORM A PRESSURE/LEAK INTEGRITY TEST ON THE SYSTEM AFTER REPAIRS. AFTER SUCCESSFUL VERIFICATION, ISSUE A VALID COC FOR CHLORINE GAS INSTALLATION. PROVIDE A DETAILED ASSESSMENT AND REPAIR REPORT. APPLICATION STANDARDS AND REGULATION: OHS ACT (PRESSURE REGULATION EQUIPMENT. SANS 10265 THE HANDLING, STORAGE, AND DISPOSAL OF CORROSIVE SUBSTANCE. SANS 10260/SANS 347 PRESSURE EQUIPMENT AND GAS INSTALLATION. CONTRACTOR REQUIREMENTS: MUST BE REGISTERED GAS PRACTITIONER QUALIFIED FOR CHLORINE GAS INSTALLATION. MUST HAVE A VALID REGISTRATION WITH SOUTH AFRICAN GAS ASSOCIATION OR OTHER APPROVED AUTHORITY. MUST PROVIDE PROOF OF QUALIFICATIONS, COC ISSUING AUTHORITY APPROVAL. MUST SUPPLY OWN TOOLS , TESTING EQUIPMENT, AND PPE SUITABLE FOR HAZARDOUS GAS. DELIVERABLES: DEATAILED ASSESSMENT REPORT WITH FINDINGS AND RECOMMENDATIONS. RECORD ALL REPAIRS OR ADJUSTMENTS MADE. COMPLETED LEAK/ INTEGRITY TEST CERTIFICATE. THE INPECTORS MUST BE REGISTERED WITH THE DEPARTMENT OF LABOUR AS AN APPROVED INSPECTOR AUTHORITY

RFQ – REQUEST FOR QUOTATION FOR REPLACEMENT OF THE EXISTING CRACKED VC GAS FEEDER UNIT (W3T174962-V10K) AND ENSURE SAFE, RELIABLE, AND ACCURATE CHLORINE GAS DOSING OPERATION. SUPPLY A COMPLETE REPLACEMENT UNIT MATCHING THE TECHNICAL SPECIFICATIONS PROVIDED. ENSURE COMPATIBILITY WITH THE EXISTING CHLORINE GAS DOSING SYSTEM AND PIPEWORK. DELIVER ALL MOUNTING ACCESSORIES, FASTENERS, AND GASKETS REQUIRED FOR INSTALLATION. PROVIDE COC AND MANUFACTURE'S DATA SHEET WITH DELIVERY. THE REPLACEMENT UNIT MUST BE FACTORY CALIBRATED AND TESTED BEFORE DISPATCH. WARRANTY AND DOCUMENTATION: MINIMUM 12 MONTH WARRANTY FROM DATE OF COMMISSIONING. SUPPLY OPERATION AND MAINTENANCE MANUAL. PROVIDE CALIBRATION AND TEST CERTIFICATES. EQUIPMENT DETAIL: MODEL; VC GAS FEEDER V10K. TYPE; REMOTE VACUUM GAS CONTROL UNIT. CAPACITY: 10KG/H. TAG: W3T174962. MOUNTING: WALL MOUNTED DESIGN. MANUFACTURER/EQUIVALENT: ORIGINAL OR EQUIVALENT APPROVED MODEL. SHE FILE MUST BE SUBMITTED WITHIN 7 DAYS OF RECEIVING THE ORDER. ATTACH A LETTER OF GOOD STANDING.

RFQ – REQUEST FOR QUOTATION FOR SERVICE PROVIDER MUST DO RECONDITIONING, REPAIR, AND REINSTATE SATURATOR PUMP AND RELATED COMPONENTS. PERFORM FULL INSPECTION ON INTERNAL COMPONENTS OF THE PUMP. ( BEARINGS, IMPELLER, SHAFT, SLEEVE, MECHANICAL SEAL ETC.). REPLACE WORN OR DEFECTIVE PARTS AS REQUIRED. CHECK SHAFT RUN-OUT AND ALIGNMENT. CLEAN ALL COMPONENTS AND REMOVE SCALE OR CORROSION. REASSEMBLE THE PUMP USING NEW GASKETS, SEALS AND FASTENERS WHERE REQUIRED. CONDUCT PUMP TESTING PRIOR TO INSTALLATION. REPLACE BEARINGS AND LUBRICATION ACCORDING TO OEM SPEC. INSPECT SUCTION AND DISCHARGE PIPEWORK FOR CORROSION, CRACKS AND MISALIGNMENT. REPAIR OR REPLACE DAMAGED PIPE SECTION. REPLACE GASKETS AND FASTENERS. INSPECT PUMP BASE AND FOUNDATION HOLD-DOWN BOLTS. REPAIR OR RE-TAP DAMAGED THREATS. INSTALL NEW HIGH-TENSILE BOLTS WHERE REQUIRED. VERIFY PUMP BASE IS SECURE AND LEVEL. REINSTALL THE PUMP. PERFORM LASER ALIGNMENT BETWEEN MOTOR AND PUMP. CHECK COUPLING CONDITION AND REPLACE IF REQUIRED. SERVICE PROVIDER MUST PROVIDE: LIST OF PARTS REPLACED, ALIGNMENT REPORT, COMMISSIONING REPORT. SERVICE PROVIDER MUST PROOF OF THE FOLLOWING: COIDA, RELEVANT EXPERIENCE IN KSB OR SIMILAR CENTRIFUGAL PUMPS. SAFETY FILE MUST BE SUBMITTED WITHIN 7 DAYS OF RECEIVING THE PO. SP MUST SUBMIT PROOF OF EXISTING APPROVED AND OPERATIONAL WORKSHOP FACILITY. PUMP SPEC: MAKE: KSB ETANORM 080-065-250 03. 01504078

RFQ – REQUEST FOR QUOTATION FOR SERVICE, MAINTENANCE AND REPAIR OF 10 X SHARP BP-50C31 PRINTERS. I. MAINTENANCE & SUPPORT X12 MONTHS - PREVENTIVE MAINTENANCE - BREAKDOWN REPAIRS AND REPLACEMENT OF FAULTY PARTS. - LABOUR - TECHNICAL SUPPORT - 48-HOUR RESPONSE SLA N.B COUNTERFEIT PARTS WILL NOT BE ACCEPTED. II. CONSUMABLES - SUPPLY AND REPLACEMENT OF TONERS (BLACK, CYAN, MAGENTA, YELLOW). N.B COUNTERFEIT TONERS WILL NOT BE ACCEPTED. N.B CONSUMABLES MUST BE COURIERED TO RUSTENBURG HEAD OFFICE TO MINIMISE TRAVELLING COSTS III. REPAIR OF EXISTING FAULTS ON PRINTERS (PRIOR CONTRACT). X3 IV. TRAVELLING COSTS - TRAVEL CHARGES APPLY ONLY WHEN ON-SITE ATTENDANCE IS REQUIRED. SITES: BRITS X 1, CULLINAN X 1, KLIPDRIFT X 1, MMABATHO X 1, RUSTENBURG X 3, TAUNG X 1, VAALKOP X 1, WALMANSDAL X 1

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF DENSO TAPE 1. DENSO TAPE (100MMX10M) 2. PACKING (SET/120X65X95X25X1/2) 3. PACKING (SET/12X60X85) 4. PACKING (SET/12X50X75) 5. PACKING (SET/10X70X50) 6. NICKEL ANTI SEIZE (500ML) 7. SLASHER - NYLON LINE (ROLL 2MM X 50M) 8. TYRE ONLY A80_T 9. TYRE ONLY A100_T 10. TYRE ONLY A60_T 11. HRC COUPLING 180 12. HRC COUPLING 230 13. F90 TYRE COUPLING 14. STRAINER PVC DOUBLE UNION /BSP 20MM 15. CUTTING NOZZLE 1.2MM PORTAPAK 16. NOZZLES ACETYLENE HAND CUTTING

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF NOZZLE CLEARNER 1. NOZZLE CLEANER 2. BATTERY THERMINALS +P 3. BATTERY THERMINALS -N 4. FLASHBACK TORCH MOUNTED OXYGEN 5 5. SLASHER - NYLON LINE (ROLL 2MM X 50M) 10 6. BALL VALVE EPDM 25MM PN16 7. SOCKETS (32PN16 PVC) 8. 50MM PVC UNIONS 9. 32MM PVC UNIONS

RFQ – REQUEST FOR QUOTATION FOR QUANTITY PHYSICAL (MECHANICAL AND MANUAL) CLEARING/REMOVAL AND DISPOSAL OF 100 HECTORS OF FLOATING AQUATIC WEEDS AT VAALKOP DAM. THE FOLLOWING MACHINERY MUST BE INCLUDED IN THE QUOTE, BUT NOT LIMITED TO: - EXCAVATORS, 20T ON A WET RATE WITH 6-8 CUBES BUCKET - PUSHER BOAT - TLB - NUMBER OF MANUAL LABOURERS PAST WORK EXPERIENCE: DEMONSTRATION OF EXPERIENCE AND UNDERSTANDING OF THE REMOVAL OF FLOATING AQUATIC WEED: PROJECT DATE, LIST OF SCOPES OF WORK, AND AT LEAST ONE REFERENCE. DISPOSAL AT THE APPROPRIATE SITE: DISPOSAL CERTIFICATE FOR THE AQUATIC WEED. SITE ESTABLISHMENT FEE MUST BE INCLUDED IN THE QUOTE.

RFQ – REQUEST FOR QUOTATION FOR SERVICE ALL AIR CONDITIONERS AT HEAD OFFICE (RUSTENBURG) 1.1. SERVICE ALL AIR CONDITIONERS (53) AND FRIDGES (3) SERVICE SHALL INCLUDE NOT LIMITED THE BELOW ONLY REMOVE AIR FILTERS, CLEAN AND RE-INSTALL CORRECTLY AND ENSURE THAT THE FILTER FRAME AND MEDIA IS FITTED PROPERLY WITH NO BYPASS OR OBSTRUCTION CHECK AND CORRECT CONDENSATE DRAIN IF NECESSARY CHECK CONDITION AND OPERATION OF THERMOSTAT AND CONTROL CHECK ELECTRICAL WIRING AND COMPONENT CONDITION AND OPERATION CHECK FOR CORRECT CONDENSER AIR PATH AND ENSURE THAT UNIT IS FREE FROM ANY RE-CIRCULATION CHECK CONDENSER FAN FOR OPERATION VIBRATION AND NOISE, REPORT TO THE CLIENT CHECK COMPRESSOR FOR OPERATION VIBRATION AND NOISE, REPORT TO THE CLIENT CHECK COOLING CYCLE CHECK HEATING CYCLE CHECK FOR GAS LEAKS, REPAIR AND TOP UP WITH REFRIGERANT IF REQUIRED CHECK FOR PIPE INSULATION DAMAGE, REPAIR AND VAPOUR SEAL IF REQUIRED REPORT TO THE CLIENT CHECK UNIT AND UNIT CASING FOR CORRECT POSITION AND BRACKETS ARE TIGHT CHECK AIR GRILLES AND DIFFUSERS CONDITION, CORRECT POSITION AND ADJUSTMENT CHECK FAN AND MOTOR FOR ABNORMAL NOISE AND VIBRATION AND REPORT TO THE CLIENT CHECK CIRCUIT BREAKERS, STARTER, OVERLOADS, AND ALL OTHER ELECTRICAL AND CONTROL COMPONENTS FOR CONDITION AND OPERATION CLEAN CONDENSER AND EVAPORATOR CLEAN DRIP TRAY AND DRAIN PIPE CLEAN EVAPORATOR AND CONDENSER FAN

RFQ – REQUEST FOR QUOTATION FOR 1. PLANT 2 SUPPLY CABLE INSTALL & COMISSION 2. SUPPLY, INSTALL AND TEST A MEDIUM VOLTAGE CABLE. A) CABLE FAULT LOCATION B) SUPPLY, INSTALL AND TEST MEDIUM VOLTAGE CABLE C) SUPPLY AND INSTALL A MEDIUM VOLTAGE TERMINATION KIT X 6 D) PERFORM PRESSURE TESTING E) PERFORM PHASING E) TRENCHING 3. OBJECTIVES THE OBJECTIVE IS TO OUTSOURCE AN EXPERIENCED CONTRACTOR FOR THE REPAIRS OF MEDIUM VOLTAGE SWITCHGEAR AND TRANSFORMERS IN VAALKOP WTP. 4. DELIVERABLES FULLY FUNCTIONAL MEDIUM VOLTAGE SWITCHGEAR AND TRANSFORMERS MENTIONED ABOVE. 5. EVALUATION PHASES PHASE 1: ADMINISTRATION COMPLIANCE (IF NOT SUBMITTED BID WILL BE DISQUALIFIED) PHASE 2: FUNCTIONAL /TECHNICAL EVALUATION PHASE 3: POINTS AWARDED FOR PRICE AND B-BBEE STATUS LEVEL OF CONTRIBUTION (80/20 PREFERENTIAL POINT SYSTEM) PHASE 1

RFQ – REQUEST FOR QUOTATION FOR TRAINING – CONFINED SPACE DURATION OF COURSE: 1 DAY NUMBER OF DELEGATES: 120 PLANTS/ AREA’S: SOUTHWEST (TAUNG), FAR WEST (MAFIKENG), AREA EAST (KLIPDRIFT) AND AREA WEST (VAALKOP)

RFQ – REQUEST FOR QUOTATION FOR TRAINING - BREATHING APPARATUS DURATION OF THE COURSE: 01 DAY NUMBER OF DELEGATES: 80 PLANTS/ AREA’S: SOUTHWEST (TAUNG), FAR WEST (MAFIKENG), AREA EAST (KLIPDRIFT) AND AREA WEST (VAALKOP)

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF STRAIGHT COUPLINGS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF BULK WATER METER MEISTREAM

RFQ – REQUEST FOR QUOTATION FOR DESIGN, MANUFACTURE, SUPPLY, INSTALLATION AND COMMISSIONING OF A 1M3/HR REVERSE OSMOSIS POINT OF ENTRY (POE) WATER TREATMENT SYSTEM FOR MAGALIES WATER SCIENTIFIC SERVICES

RFQ – REQUEST FOR QUOTATION FOR SUPPLY, DELIVERY AND INSTALLATION OF 3 CONTAINERS WITH WINDOWS

RFQ – REQUEST FOR QUOTATION FOR SERVICE OF MOLEAR NANUBUBBLES

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVER 2 X RIDE ON MOWERS TO LEEUDORINGSTAD PUMPSTATION

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALL NEW DN 400 PN 25 DIAPHRAGM VALVES

RFQ – REQUEST FOR QUOTATION FOR REPLACINGPLANT 2B MAG FLOWMETER

RFQ – REQUEST FOR QUOTATION FOR DAM WALL OVERHEAD CRANE REPAIRS 10TON CAPACITY

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF MATERIAL FOR THE CONNECTION OF 300 AND 500MM METERS CONNECTION. SUPPLY AND DELIVERY OF METERS FOR THE INSTALLATION OF 300 AND 500MM PN16 WATER METERS AT MAFIKENG PLANT

RFQ – REQUEST FOR QUOTATION TO SUPPLY AND INSTALL THE NEW FABRICATED Y- PIECE

RFQ – REQUEST FOR QUOTATION TO SUPPLY AND DELIVERY: - TAP PLASTIC 20MM 500 2 COUPLING PLASSON 20MM 200 3 COUPLING PLASSON 25X20MM 150 4 CASCADE CLAMP (CRI-0600-08) 150-161 50 5 ELBOW GALVANISED F/F 20MM 200 6 NIPPLES (GALVANIZED - 20MM) 200 7 NIPPLES (40MM - BARREL GALVANIZED) 50 8 PLUGS HOLLOW (20MM GALVANIZED) 100 9 COUPLING PLASSON 25MM 100 10 COUPLING PLASSON 50MM 100 11 STAND PIPES 3/4"(20MM) 50 12 M12 X 50MM BOLTS 50 13 BOLTS & NUTS (H/T - 20MMX80MM) 50 14 BOLTS & NUTS (MILD STEEL - 10MMX80MM)

RFQ – REQUEST FOR QUOTATION TO SUPPLY TURBIDITY METER

RFQ – REQUEST FOR QUOTATION FOR METER VERIFICATION

RFQ – REQUEST FOR QUOTATION FOR REFURBISHING WORKSHOP

RFQ – REQUEST FOR QUOTATION TO REPLACE ELPRO RADIOS

RFQ – REQUEST FOR QUOTATION TO SUPPLY AND INSTALL NEW BLOWER

RFQ – REQUEST FOR QUOTATION TO REPLACE VSD

RFQ – REQUEST FOR QUOTATION TO SUPPLY CLAMP ON METER

RFQ – REQUEST FOR QUOTATION TO SUPPLY TOOLBOXES

RFQ – REQUEST FOR QUOTATION TO RESTORE COMMUNICATION

RFQ – REQUEST FOR QUOTATION TO SUPPLY AND INSTALL ALARM

RFQ – REQUEST FOR QUOTATION TO REPLACE MECHANICAL SEAL

RFQ – REQUEST FOR QUOTATION FOR CONDUCT A MAJOR HAZARDOUS INSTALLATION (MHI) RISK ASSESSMENT AT SOUTHWEST

RFQ – REQUEST FOR QUOTATION FOR STATUTORY INSPECTION ON LIFTS

RFQ – REQUEST FOR QUOTATION FOR REPAIR SSE TELEMETRY FOR KORTBEGRIP, MONAKOTA, EVERGREEN & SPITSKOP RESERVIORS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY FIRE HYDRANT HOSES AT VAALKOP IN QUANTITY OF 10. SUPPLY AND DELIVER SABS APPROVED FIRE HYDRANT POLYZ FIRE HOSE WITH COUPLINGS AND NOZZLE CONNECTED TO THE HOSE AND MUST BE ANON-ERCOLATING HOSE WITH A ROBUST, ALL-SYNTHETIC JACKET, DESIGNED AS A BOX HOSE WITH NO NEED TO DRY AFTER USE AND IF NECESSARY, CAN BE REPAIRED EASILY. COIL DIAMETER 410MM AND LENGTH 30M WITH THE OPERATING PRESSURE KPA 1800. SUPPLY AND DELIVERY FIRE HYDRANT HOSES AT KLIPDRIFT IN QUANTITY OF 10. SUPPLY AND DELIVER SABS APPROVED FIRE HYDRANT POLYZ FIRE HOSE WITH COUPLINGS AND NOZZLE CONNECTED TO THE HOSE AND MUST BE A NON-PERCOLATING HOSE WITH A ROBUST, ALL-SYNTHETIC JACKET, DESIGNED AS A BOX HOSE WITH NO NEED TO DRY AFTER USE AND IF NECESSARY, CAN BE REPAIRED EASILY. COIL DIAMETER 410MM AND LENGTH 30M WITH THE OPERATING PRESSURE KPA 1800

RFQ – REQUEST FOR QUOTATION FOR MODIMOLLE- MOOKGOPHONG LM CSI PROJECT 2025/26 SOURCE DEVELOPMENT AT ROEDTAN (REDRILLING OF EXISTING BOREHOLE) PROJECT: DRILLING, TESTING, AND EQUIPPING OF A BOREHOLE WITH PUMP HOUSE, VALVES, AND FLOW METER AT ROEDTAN IN MODIMOLLE-MOOKGOPONG LM

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY FIRE HYDRANT HOSES AT VAALKOP IN QUANTITY OF 10

RFQ – REQUEST FOR QUOTATION FOR CONDUCT A MAJOR HAZARDOUS INSTALLATION SOUTH WEST MHI (TAUNG WTP, KGOMOTSO WTP, BLOEMHOF WWTP, BLOEMHOF WTW, LEEUDORINGSTAD) THE ASSESSMENT MUST BE CONDUCTED BY COMPETENT ASSESSORS WITH EXPERIENCE IN MHI IN ACCORDANCE WITH SANS 1461, AS AMENDED. ATTACH PROOF. THE RISK ASSESSMENT MUST BE CONDUCTED AS PER THE UPDATED MHI REGULATIONS. THE COMPANY MUST PROVIDE A DETAILED REPORT WITH FINDINGS AND RECOMMENDATIONS AFTER CONDUCTING THE RISK ASSESSMENTS. CONDUCT A MAJOR HAZARDOUS INSTALLATION (MHI) RISK ASSESSMENT AT FAR WEST (MMABATHO WTW, MAFIKENG WTW)

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY: - HABONIM C60-TYPE COMPACT PNEUMATIC ACTUATORS X 2

RFQ – REQUEST FOR QUOTATION FOR HYGIENE SERVICES FOR SOUTHWEST FOR 24 MONTHS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF WATER TANKERS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY - 10 KL JOJO TANKS WITH FLANGES AND LIDS ON TOP

RFQ – REQUEST FOR QUOTATION FOR SHE LEGAL REGISTER FOR 3 YEARS

RFQ – REQUEST FOR QUOTATION FOR WATER TANKER SERVICES AT THE GREATER TAUNG LOCAL MUNICIPALITY

RFQ – REQUEST FOR QUOTATION FOR SECURITY ESS- MAINTENANCE AND SERVICING OF ELECTRONIC SECURITY SYSTEM AT VARIOUS MAGALIES WATER SITES

RFQ – REQUEST FOR QUOTATION FOR DESIGN, MANUFACTURE, SUPPLY, INSTALLATION AND COMMISSIONING OF A 1M3/HR REVERSE OSMOSIS POINT OF ENTRY (POE) WATER TREATMENT SYSTEM FOR MAGALIES WATER SCIENTIFIC SERVICES

RFQ – REQUEST FOR QUOTATION FOR MORETELE LM CSI PROJECT 2025/26

RFQ – REQUEST FOR QUOTATION FOR GOOSE NECK AND IDT AND PRESSURE TESTING

RFQ – REQUEST FOR QUOTATION FOR ONSITE-MACHINING HPH 58 PUMP AND MECH SEAL

RFQ – REQUEST FOR QUOTATION FOR MORETELE LM CSI PROJECT 2025/26

RFQ – REQUEST FOR QUOTATION FOR REPAIR/REBABBITT, BABBITED BEARINGS & MACHINE TO SIZE

RFQ – REQUEST FOR QUOTATION FOR REPAIR/REBABBITT, BABBITED BEARINGS & MACHINE TO SIZE

RFQ – REQUEST FOR QUOTATION FOR TRAINING - BREATHING APPARATUS

RFQ – REQUEST FOR QUOTATION FOR TRAINING – CONFINED SPACE

RFQ – REQUEST FOR QUOTATION FOR EMERGENCY PUMP REPAIRS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALL GATAOTE HIGHLIFT PUMP

RFQ – REQUEST FOR QUOTATION FOR APPOINTMENT OF THE PSP ON THE ROOIGRON PROJECT

RFQ – REQUEST FOR QUOTATION FOR CONSULTANCY SERVICES - MAGALIES WATER ORGANISATIONAL STRATEGY, STRATEGIC RISK REGISTER REVIEW, GROWTH STRATEGY AND FACILITATION OF STRATEGY PLANNING SESSIONS AND RISK ASSESSMENT SESSION

RFQ – REQUEST FOR QUOTATION FOR MAGALIES WATER HARTBEESPOORT DAM REHABILITATION PROJECT ANNUAL REPORT

RFQ – REQUEST FOR QUOTATION FOR COMMUNITY MEDIA BUYING FOR SOUTHWEST REGION AWARENESS CAMPAIGN

RFQ – REQUEST FOR QUOTATION FOR SUPPLY GARDEN SERVICE TO VAALKOP PLANT FOR 3 MONTHS

RFQ – REQUEST FOR QUOTATION FOR ESTABLISH AN IN-HOUSE PERSONNEL SUITABILITY CHECK (PSC) SYSTEM FOR THE SECURITY SCREENING OF NATURAL AND JURISTIC PEOPLE EMPLOYED, CONTRACTED OR IN THE PROCESS OF BEING EMPLOYED OR CONTRACTED BY MAGALIES WATER TO RENDER SERVICES

RFQ – REQUEST FOR QUOTATION FOR BULK WATER METERS MEISTREAM

RFQ – REQUEST FOR QUOTATION FOR TRANSMITTER MX 2034

RFQ – REQUEST FOR QUOTATION FOR SPECTROMETER

RFQ – REQUEST FOR QUOTATION FOR REPLACE XLP CABLE WALMAN PLANT

RFQ – REQUEST FOR QUOTATION FOR REPLACE DAMAGE ALTIVAR VSD WALL

RFQ – REQUEST FOR QUOTATION FOR REPAIR OF DR1900 METER

RFQ – REQUEST FOR QUOTATION FOR BP 32 HLP HM OIL 20L

RFQ – REQUEST FOR QUOTATION FOR MILD STEEL PLATE 5MM*1.2M*2.5M

RFQ – REQUEST FOR QUOTATION FOR FIXED PROP P.RED VALVE 80MM (800S)

RFQ – REQUEST FOR QUOTATION FOR INSTALLATION OF A BYPASS KHOTSO SECTION

RFQ – REQUEST FOR QUOTATION FOR ELECTRICAL METER APPLICATION INSTALLATION ON 4 BOREHOLES

RFQ – REQUEST FOR QUOTATION FOR BLOWER RESTORATION

RFQ – REQUEST FOR QUOTATION FOR BUILDING OF BANDWALL AT ALL PLANTS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF ICT TOOLS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF SUBMERSIBLE PUMP

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF HDPE PIPE

RFQ – REQUEST FOR QUOTATION FOR SCADA, HMI FOR CHRISTIANA, PODUMOE, AND BLOEMHOF PLANT

RFQ – REQUEST FOR QUOTATION FOR EMPTYING OF SEPTIC TANK AT MAGALIES WATER PLANTS FOR 6 MONTHS. ALL WASTE MUST BE DISPOSED OFF AT A REGISTERED FACILITY

RFQ – REQUEST FOR QUOTATION FOR THE APPOINTMENT A PROFESSIONAL SERVICE PROVIDER TO CONDUCT AN ASSESSMENT AND PROVIDE A REPORT THAT WILL SERVE AS AN ADVISORY TOWARDS AN EEFFICIENT AND EFFECTIVE SECURITY SERVICES

RFQ – REQUEST FOR QUOTATION FOR SUPPY AND DELIVERY OF INSULATION TAPE

RFQ – REQUEST FOR QUOTATION FOR SUPPY AND DELIVERY OF DENSO TAPE

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF NOZZLE CLEARNER

RFQ – REQUEST FOR QUOTATION FOR TAUNG MEDIA CAMPAIGN OB

RFQ – REQUEST FOR QUOTATION FOR PLUGS PLASSON

RFQ – REQUEST FOR QUOTATION FOR PIPE STEEL 150MM

RFQ – REQUEST FOR QUOTATION FOR MILD STEEL PLATE

RFQ – REQUEST FOR QUOTATION FOR PIPE 350MM PN25 FUSION BOND EPOXY COAT

RFQ – REQUEST FOR QUOTATION FOR FLANGE ADAPTOS

RFQ – REQUEST FOR QUOTATION FOR DPD CHLORINE

RFQ – REQUEST FOR QUOTATION FOR BESTOBELL GASKET

RFQ – REQUEST FOR QUOTATION FOR BID COMMITTEE WORKSHOP TRAINING FOR TWO (2) DAYS: 2 AND 3 FEBRUARY 2026 FOR 30 DELEGATES

RFQ – REQUEST FOR QUOTATION FOR STATUTORY INSPECTION ON LIFTS

RFQ – REQUEST FOR QUOTATION FOR REPAIRING OF VAALKOP MAIN GATE AND BOOM

RFQ – REQUEST FOR QUOTATION FOR REFURBISHMENT OF PLANT 4 HLPS PUMP3 VALVES

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALLATION OF NEW DN 400 PN 40 REPLACEMENT PLUNGER VALVE WITH GEARBOX X1 AS PER BELOW SPECIFICATION

RFQ – REQUEST FOR QUOTATION FOR SUPPLY ELECTRICAL CABLES AND SPARES

RFQ – (RE -ADVERT ) MAGALIES WATER HARTBEESPOORT DAM REHABILITATION PROJECT ANNUAL REPORT

RFQ – REQUEST FOR QUOTATION FOR MAGALIES WATER CLOUD HOSTING & REMOTE SERVER BACKUP FOR THREE YEARS (2025 2027)

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALL DN 450 PN 10 DOUBLE FLANGED REPLACEMENT SUCTION VALVE WITH GEARBOX AND HANDWHEEL

RFQ – REQUEST FOR QUOTATION FOR SUPPLYING SCREW PUMP COUPLING SPARES

RFQ – REQUEST FOR QUOTATION FOR SUPPLY OF PERSONNEL SUITABILITY CHECKS

RFQ – (RE -ADVERT ) REQUEST FOR QUOTATION FOR SERVICE PROVIDERS INVITED TO BID FOR THE APPOINTMENT A PROFESSIONAL SERVICE PROVIDER TO CONDUCT AN ASSESSMENT AND PROVIDE A REPORT THAT WILL SERVE AS AN ADVISORY TOWARDS AN EEFFICIENT AND EFFECTIVE SECURITY SERVICES

RFQ – REQUEST FOR QUOTATION FOR CONDUCTING OF SKILLS AUDIT

RFQ – REQUEST FOR QUOTATION FOR APPOINTMENT OF A PROFESSIONAL SERVICE PROVIDER (PSP) TO ASSIST WITH THE DEVELOPMENT AND FINALIZATION OF THE ORGANIZATIONAL STRUCTURE FOR MAGALIES WATER

RFQ – REQUEST FOR QUOTATION FOR APPOINTMENT OF A PROFESSIONAL SERVICE PROVIDER (PSP) TO ASSIST WITH THE DEVELOPMENT AND FINALIZATION OF THE ORGANIZATIONAL STRUCTURE FOR MAGALIES WATER

RFQ – REQUEST FOR QUOTATION FOR AN EXTENSION SUMP AT SUPERNATANT

RFQ – REQUEST FOR QUOTATION FOR REPLACEMENT OF PLANT WINDOWS AND DOORS

RFQ – REQUEST FOR QUOTATION FOR EMPTYING OF SEPTIC TANK AT MAGALIES WATER PLANTS FOR 6 MONTHS

RFQ – REQUEST FOR QUOTATION FOR PHYSICAL (MECHANICAL AND MANUAL) CLEARING/REMOVAL AND DISPOSAL OF 100 HECTORS OF FLOATING AQUATIC WEEDS AT VAALKOP DAM

RFQ – REQUEST FOR QUOTATION FOR REMOVAL OF BEES AT VAALKOP, HEAD OFFICE, MMABATHO REGIONAL OFFICE, MMABATHO WTW, MAFIKENG WTW, TSWASA WTW, LOKALENG PUMPSTATION, MOTSWEDI WTW, INTERMEDIATE PUMPSTATION, MOLATEDI DAM, MOROKWENG OFFICE, GANYESA DISTRICT, PUDIMOE WTW, TAUNG DISTRICT, HARTSWATER, KGOMOTSO WTW, CHRISTIANA WTW, CHRISTIANA WWTW, BLOEMHOF WTW, BLOEMHOF WWTW, LEEUDORINGSTAD, WALLMANNSTHAL, KLIPDRIFT AND CULLINAN FOR A PERIOD OF 12 MONTHS

RFQ – REQUEST FOR QUOTATION FOR REVIEW OF THE RESOURCE MANAGEMENT PLAN (RMP) FOR THE HARTBEESPOORT DAM REMEDIATION PROJECT

RFQ – (RE -ADVERT ) REQUEST FOR QUOTATION FOR RAW WATER INSPECTION - DIVER

RFQ – (RE -ADVERT ) REQUEST FOR QUOTATION FOR AN EXTENSION SUMP AT SUPERNATANT

RFQ – (RE -ADVERT ) REQUEST FOR QUOTATION FOR REPAIRING LEAKS INSIDE CONCRETE

RFQ – (RE -ADVERT ) REQUEST FOR QUOTATION FOR REPLACEMENT OF PLANT WINDOWS AND DOORS

RFQ – (RE -ADVERT ) REQUEST FOR QUOTATION FOR SERVICING OF PRESSURE CONTROL VALVE

RFQ – REQUEST FOR QUOTATION FOR ToR TECHNICAL ASSESSMENT FOR THE PIPELINE PADDA JUNCTION TO THABAZIMBI

RFQ – REQUEST FOR QUOTATION FOR APPOINTMENT OF THE PSP ON THE ROOIGROND PROJECT

RFQ – REQUEST FOR QUOTATION FOR EMPTYING OF SEPTIC TANK AT CULLINAN PLANT FOR 6 MONTHS

RFQ – REQUEST FOR QUOTATION FOR CLOUD BASED GIS ENTERPRISE AND PORTAL HOUSING

RFQ – REQUEST FOR QUOTATION FOR NETWORK MONITORING TOOL FOR 36 MONTHS

RFQ – REQUEST FOR QUOTATION FOR QUANTITY SUPPLY OF TOOLS AND EQUIPMENT TO THE FAR WEST MAINTENANCE TEAM MAINTENANCE TOOLS

RFQ – REQUEST FOR QUOTATION FOR QUANTITY SUPPLY AND DELIVERY OF MATERIAL FOR THE CONNECTION OF 300 AND 500MM METERS CONNECTION

RFQ – REQUEST FOR QUOTATION FOR QUANTITY SUPPLY, DELIVER AND INSTALL SHE COMPLIANCE SIGNS FOR A PERIOD OF TWO YEARS. THE INSTALLATION MUST BE CONDUCTED AT VARIOUS SITES FOR THE FOLLOWING AREAS

RFQ – REQUEST FOR QUOTATION FOR QUANTITY EMPTYING OF SEPTIC TANK AT CULLINAN PLANT FOR 6 MONTHS

RFQ – REQUEST FOR QUOTATION FOR CONDUCTING A MAJOR HAZARDOUS INSTALLATION (MHI) RISK ASSESSMENT AT SOUTH WEST: 1. SOUTH WEST (TAUNG WTP, KGOMOTSO WTP, BLOEMHOF WWTP, BLOEMHOF WTW, LEEUDORINGSTAD)

RFQ – REQUEST FOR QUOTATION FOR CONDUCTING AN INTERNAL AUDITS FOR BOTH THE ISO45001:2015 (HEALTH AND SAFETY MANAGEMENT SYSTEM) AND ISO14001:2018 (ENVIRONMENTAL MANAGEMENT SYSTEM)

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF HIGH PERFORMANCE MARQUEE INDUSTRIAL AIR-CONDITIONING UNITS

RFQ – REQUEST FOR QUOTATION FOR HIRING OF A LED TRUCK

RFQ – REQUEST FOR QUOTATION FOR HIRING OF TENTS AT JOC

RFQ – REQUEST FOR QUOTATION FOR SUPPLY OF TRANSPORTATION SERVICES - BETHANIE

RFQ – REQUEST FOR QUOTATION FOR SUPPLY OF CATERING SERVICES - BETHANIE

RFQ – REQUEST FOR QUOTATION FOR HIRING OF TENT ON 06 JANUARY 2025 AT VAALKOP WATER TREATENT PLANT

RFQ – REQUEST FOR QUOTATION FOR SUPPLY OF CATERING ON 06 JANUARY 2025 AT VAALKOP WATER TREATENT PLANT

RFQ – REQUEST FOR QUOTATION FOR SUPPLY OF TRANSPORT ON 06 JANUARY 2025 AT VAALKOP WATER TREATENT PLANT

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALLATION OF PN10 DN500 MECHANICAL METER

RFQ – REQUEST FOR QUOTATION FOR REPAIRING OF LOKALENG BOOSTER PUMPS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF MATERIAL FOR THE CONNECTION OF 300MM BULK METER

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF MATERIAL FOR THE CONNECTION OF 300 AND 500MM METERS CONNECTION

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF COMMUNITY MEDIA BUYING FOR SOUTHWEST REGION AWARENESS CAMPAIGN

RFQ – REQUEST FOR QUOTATION FOR SUPPLY, DELIVERY AND INSTALLATION OF CELLPHONE SIGNAL BOOSTER IN VAALKOP

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF CLOUD BASED GIS ENTERPRISE AND PORTAL HOUSING

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF NETWORK MONITORING TOOL FOR 36 MONTHS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF MAGALIES WATER HARTBEESPOORT DAM REHABILITATION PROJECT ANNUAL REPORT

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF WATER CONSERVATION AND DEMAND MANAGEMENT: ZONAL METERING

RFQ – REQUEST FOR QUOTATION FOR THE SLUDGE CLASSIFICATION,ANALYSIS, REPORT AND INTERPRETATION FOR TAUNG, SCHWEIZER RENEKE, CHRISTIANA, BLOEMHOF, PUDIMOE, KGOMOTSO, MMABATHO, MOTSWEDI WATER TREATMENT PLANT

RFQ – REQUEST FOR QUOTATION FOR THE ANNUAL SERVICE OF FIRE EXTINGUISHERS AT VAALKOP

RFQ – REQUEST FOR QUOTATION FOR CONDUCTING OCCUPATIONAL HAZARDOUS CHEMICAL AGENT SURVEY AT GANYESA DISTRICT, SCHWEIZER RENEKE WTW, PUDIMOE WTW, TAUNG WTW, HARTSWATER WORKSHOP, KGOMOTSO WTW, BLOEMHOF WTW, BLOEMHOF WWTW, CHRISTIANA WTW, LEEUDORINGSTAD, AND CHRISTIANA WWTW

RFQ – REQUEST FOR QUOTATION FOR SUPPLYING AND DELIVERY OF GATE VALVE AND VENT

RFQ – REQUEST FOR QUOTATION FOR SUPPLYING REMOTE ROTAMETER

RFQ – REQUEST FOR QUOTATION FOR REPAIRING LEAKS INSIDE CONCRETE

RFQ – REQUEST FOR QUOTATION FOR THE APPOINTMENT OF THE PSP ON THE ROOIGRON PROJECT

RFQ – REQUEST FOR QUOTATION FOR TECHNICAL ASSESSMENT FOR THE PIPELINE PADDA JUNCTION TO THABAZIMBI

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF 2026 MAGALIES WATER CALENDARS AND NOTEBOOKS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY, DELIVERY AND INSTALLATION OF MECHANICAL SEALS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF MONO PIPES

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF HIRED MOBILE TOILETS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF POLYPRO BLUE 10 000 LTR WATER TANK

RFQ – REQUEST FOR QUOTATION TO SUPPLY & INSTALL NEW DN 400 PN 25 2C VALVES

RFQ – REQUEST FOR QUOTATION FOR SCADA , HMI FOR CHRISTIANA, PODUMOE, AND BLOEMHOF PLANTS

RFQ – REQUEST FOR QUOTATION FOR SCADA , HMI FOR CHRISTIANA, PODUMOE, AND BLOEMHOF PLANTS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY, REGISTRATION AND DELIVERY OF GORMAN RUPP PUMP ON A TRAILER

RFQ – REQUEST FOR QUOTATION TO SUPPLY, DELIVERY, INSTALL AND MAINTENANCE OF HYGIENE PRODUCTS TO THE 4 PLANTS AS WELL AS HO AND BRITS LAB FOR A DURATION OF 24 MONTHS.

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF OFFICE FURNITURE

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF IFM THREAD M12

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF MULTIJET WATER METER

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF WELDING RODS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF PAINTING MATERIAL

RFQ – REQUEST FOR QUOTATION FOR WAFER AND AIR VALVE

RFQ – REQUEST FOR QUOTATION FOR REPAIRING LEAKS INSIDE CONCRETE SUMPS

RFQ – REQUEST FOR QUOTATION FOR SERVICING OF MAFENYA ALTITUTE PRESSURE CONTROL VALVE (PRV)

RFQ – REQUEST FOR QUOTATION FOR REPLACEMENT OF PLANT WINDOWS AND DOORS

RFQ – REQUEST FOR QUOTATION FOR EXTENSION SUMP AT SUPERNATANT

RFQ – REQUEST FOR QUOTATION FOR RAW WATER INSPECTION – DIVER

RFQ – REQUEST FOR QUOTATION FOR TECHNICAL ASSESSMENT FOR THE PIPELINE PADDA JUNCTION TO THABAZIMBI

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALL DN 400

RFQ – REQUEST FOR QUOTATION FOR WALL CALENDARS, DESK PAD CALENDARS AND HARD COVER NOTEBOOKS

RFQ – REQUEST FOR QUOTATION FOR COMMUNITY MEDIA BUYING FOR SOUTHWEST REGION AWARENESS CAMPAIGN

RFQ – REQUEST FOR QUOTATION FOR COMMUNITY MEDIA BUYING FOR SOUTHWEST REGION AWARENESS CAMPAIGNMAGALIES WATER HARTBEESPOORT DAM REHABILITATION PROJECT ANNUAL REPORT

RFQ – REQUEST FOR QUOTATION FOR SUPPLY REMOTE ROTAMETER

RFQ – REQUEST FOR QUOTATION FOR COMMUNITY MEDIA BUYING FOR SOUTHWEST REGION AWARENESS CAMPAIGN

RFQ – REQUEST FOR QUOTATION FOR SLUDGE CLASSIFICATION, ANALYSIS, REPORT AND INTERPRETATION FOR TAUNG, SCHWEIZER RENEKE, CHRISTIANA, BLOEMHOF, PUDIMOE, KGOMOTSO, MMABATHO, MOTSWEDI WATER TREATMENT PLANT

RFQ – REQUEST FOR QUOTATION FOR THE APPOINTMENT OF A PROFESSIONAL SERVICE PROVIDER TO CONDUCT AN ASSESSMENT AND PROVIDE A REPORT THAT WILL SERVE AS AN ADVISORY TOWARDS AN EEFFICIENT AND EFFECTIVE SECURITY SERVICES

RFQ – REQUEST FOR QUOTATION FOR SECURITY DOOR REPAIRS AND ACCESS CONTROL ENHANCEMENT PROJECT

RFQ – REQUEST FOR QUOTATION FOR THE APPOINTMENT OF THE PSP ON THE ROOIGRON PROJECT

RFQ – REQUEST FOR QUOTATION FOR SUPPLY, REGISTRATION AND DELIVERY OF GORMAN RUPP PUMP ON A TRAILER

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF WATER TANKS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF PIPES

RFQ – REQUEST FOR QUOTATION FOR SCADA , HMI FOR CHRISTIANA, PODUMOE, AND BLOEMHOF PLANTS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALL 1X REMOTE METER ROTAMETER

RFQ – REQUEST FOR QUOTATION FOR CLOUD BASED GIS ENTERPRISE AND PORTAL HOUSING

RFQ – REQUEST FOR QUOTATION FOR ICT TOOLS

RFQ – REQUEST FOR QUOTATION FOR HARTBEESPOORT DAM ANNUAL REPORT

RFQ – REQUEST FOR QUOTATION FOR SUPPLY OF TOOLS AND EQUIPMENT TO THE FAR WEST MAINTENANCE TEAM

RFQ – REQUEST FOR QUOTATION FOR SUPPLY, DELIVERY, INSTALL AND MAINTENANCE OF HYGIENE PRODUCTS TO THE 4 PLANTS AS WELL AS HO AND BRITS LAB FOR A DURATION OF 24 MONTHS

RFQ – REQUEST FOR QUOTATION TO CONDUCT OCCUPATIONAL HAZARDOUS CHEMICAL AGENT SURVEY

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF MATERIAL FOR THE CONNECTION OF BULK METERS

RFQ – REQUEST FOR QUOTATION FOR BULK METERS

RFQ – REQUEST FOR QUOTATION FOR REPAIRING VAALKOP MAIN GATE AND BOOM

RFQ – REQUEST FOR QUOTATION FOR WATER CONSERVATION AND DEMAND MANAGEMENT

RFQ – REQUEST FOR QUOTATION FOR REPLACEMENT OF PLANT WINDOWS AND DOORS

RFQ – REQUEST FOR QUOTATION FOR OFFICE REFRESHMENT FOR VAALKOP PLANT

RFQ – REQUEST FOR QUOTATION FOR MORETELE LM CSI PROJECT 2025/26

RFQ – REQUEST FOR QUOTATION FOR REPAIRING KORTBEGRIP, MONAKATO, EVERGREEN & SPITSKOP RESERVIOR TELEMETRY SYSTEMS

RFQ – REQUEST FOR QUOTATION FOR REMOVAL OF WASTE LIQUID

RFQ – REQUEST FOR QUOTATION TO SUPPLY AND DELIVERY OF FLANGES

RFQ – REQUEST FOR QUOTATION TO SUPPLY SCREW PUMP COUPLING

RFQ – REQUEST FOR QUOTATION TO SUPPLY AND DELIVERY MESH FENCE

RFQ – REQUEST FOR QUOTATION TO REPAIR HIGHLIFT MOTORS

RFQ – REQUEST FOR QUOTATION TO SERVICE OF PRESSURE CONTROL VALVE

RFQ – REQUEST FOR QUOTATION TO REPAIR LEAKS INSIDE CONCRETE

RFQ – REQUEST FOR QUOTATION FOR EXTENSION SUMP AT SUPERNATANT

RFQ – REQUEST FOR QUOTATION TO SUPPLY ELECTRICAL CABLES & SPARES

RFQ – REQUEST FOR QUOTATION FOR DAM WALL OVERHEAD CRANE

RFQ – REQUEST FOR QUOTATION TO REFURBISH PLANT 4 HLPS PUMP

RFQ – REQUEST FOR QUOTATION TO RECONDITION DIAPHRAGM VALVE

RFQ – REQUEST FOR QUOTATION TO SUPPLY AND INSTALL VALVES

RFQ – REQUEST FOR QUOTATION FOR ELECTRICAL TOOLS

RFQ – REQUEST FOR QUOTATION FOR A COMPANY TO DEVELOP THE SHE LEGAL REGISTER

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF HDPE PIPEDS

RFQ – REQUEST FOR QUOTATION FOR SUPPY AND DELIVERY OF DENSO TAPE

RFQ – REQUEST FOR QUOTATION FOR TAPE INSULATION

RFQ – REQUEST FOR QUOTATION FOR ANNUAL SERVICE OF FIRE EXTINGUISHERS AT VAALKOP

RFQ – REQUEST FOR QUOTATION FOR PHAPOSANO PIPELINE

RFQ – REQUEST FOR QUOTATION FOR METER CHECKS

RFQ – REQUEST FOR QUOTATION FOR DAF REPAIR

RFQ – REQUEST FOR QUOTATION FOR RAW WATER INSPECTION

RFQ – REQUEST FOR QUOTATION FOR REAPIRING LUTZ PUMP

RFQ – REQUEST FOR QUOTATION FOR OZONE BOOSTER PUMP

RFQ – REQUEST FOR QUOTATION TO CONDUCT PERFORMANCE MANAGEMENT MODERATION 2024/25

RFQ – REQUEST FOR QUOTATION FOR TAUNG MEDIA CAMPAIGN OB

RFQ – REQUEST FOR QUOTATION FOR A CLOUD BASED GIS ENTERPRISE AND PORTAL HOUSING

RFQ – REQUEST FOR QUOTATION FOR HYDRAULIC ANALYSIS AND PUMP ASSESSMENT IN THE FAR WEST REGION

RFQ – REQUEST FOR QUOTATION FOR LOWERING OF PUMP SET STEEL STAND AT LOKALENG AND REINFORCEMENT OF STEEL STAND AT MMABATHO PLANT

RFQ – REQUEST FOR QUOTATION FOR REPAIRING OF THE LOKALENG STEEL TANK

RFQ – REQUEST FOR QUOTATION FOR REPAIRS ON MOTSWEDI HIGH LIFT PS

RFQ – REQUEST FOR QUOTATION FOR REPAIRING OF THE LEAKING STEEL TANK AT LOKALENG PUMP STATION

RFQ – REQUEST FOR QUOTATION FOR REBUILDING AND ALIGNING PUMP

RFQ – REQUEST FOR QUOTATION FOR STRUCTURAL REPAIRS ON THE MOTSWEDI RESERVOIR

RFQ – REQUEST FOR QUOTATION FOR A CONTAINER

RFQ – REQUEST FOR QUOTATION FOR A MOBILE TOILET

RFQ – REQUEST FOR QUOTATION FOR A MECHANICAL SEAL

RFQ – REQUEST FOR QUOTATION TO CONDUCT PERFORMANCE MANAGEMENT MODERATION 2024/25

RFQ – REQUEST FOR QUOTATION FOR SECURITY DOOR REPAIRS AND ACCESS CONTROL ENHANCEMENT PROJECT

RFQ – REQUEST FOR QUOTATION TO APPOINT A SECURITY SERVICE PROVIDER FOR THE PROVISIONING OF GUARDING SECURITY SERVICES FOR ROOIGROND WASTE WATER TREATMENT PLANT FOR A PERIOD OF SIX MONTHS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY OF PERSONNEL SUITABILITY CHECKS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY, DELIVERY, INSTALL AND MAINTENANCE OF HYGIENE PRODUCTS TO THE 4 PLANTS AS WELL AS HO AND BRITS LAB FOR A DURATION OF 24 MONTHS

RFQ – REQUEST FOR QUOTATION FOR SUPPLYING CALIBRATION STANDARDS FOR WATER QUALITY INSTRUMENTS

RFQ – REQUEST FOR QUOTATION FOR CONDUCTING PERFORMANCE MANAGEMENT MODERATION 2024/25

RFQ – REQUEST FOR QUOTATION FOR INSTALLATION OF CELLPHONE SIGNAL BOOSTER IN VAALKOP

RFQ – REQUEST FOR QUOTATION FOR CONDUCTING OF SKILLS AUDIT

CANCELLED RFQ – REQUEST FOR QUOTATION FOR REPAIRING STEEL TANK

CANCELLED RFQ – REQUEST FOR QUOTATION FOR REPAIRING RECYCLE PUMP.pdf

RFQ – REQUEST FOR QUOTATION FOR SERVICES TO PROVIDE OFFSITE DOCUMENT STORAGE FACILITIES AND RENDER DOCUMENT MANAGEMENT SERVICES FOR A PERIOD OF THREE YEARS (36) MONTHS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF SERVICE BOOSTER PUMPS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF OZONE INJECTOR PUMP

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF MORETELE BYPASS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF MONO ELEMENT

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF WATER METERS

RFQ – REQUEST FOR QUOTATION FOR LOAD TESTING

RFQ – REQUEST FOR QUOTATION FOR REPAIRING A ACTUATOR

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF METER VERIFICATION

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF MAGNETIC SENSOR

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF EXTRACTOR FAN

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF DRAIN CAMERA

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF DPD CHLORINE

RFQ – REQUEST FOR QUOTATION FOR REPAIRING A RECYCLE PUMP

RFQ – REQUEST FOR QUOTATION FOR REPAIRING STEEL TANK

RFQ – REQUEST FOR QUOTATION FOR SUPPLY OF HATCH DPD CHLORINE FREE CHLORINE REAGENT

RFQ – REQUEST FOR QUOTATION FOR SUPPLY OF BODY CHEST BAG

RFQ – REQUEST FOR QUOTATION FOR SUPPLY OF POWER BANKS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY OF BRANDED BOTTLES

RFQ – REQUEST FOR QUOTATION FOR SUPPLY OF GARDEN SERVICES TO VAALKOP PLANT FOR PERIOD OF 3 MONTH

RFQ – REQUEST FOR QUOTATION FOR PRESSURE VESSEL TESTING

RFQ – REQUEST FOR QUOTATION FOR SERVICE PROVIDERS ARE INVITED TO BID FOR THE APPOINTMENT A PROFESSIONAL SERVICE PROVIDER TO CONDUCT AN ASSESSMENT AND PROVIDE A REPORT THAT WILL SERVE AS AN ADVISORY TOWARDS AN EEFFICIENT AND EFFECTIVE SECURITY SERVICES

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF SUPPLY SCREW PUMP COUPLING SPARES

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF FUEL TANKS VACUSONIC TEST & CALIBRATION

RFQ – REQUEST FOR QUOTATION FOR PROFESSIONAL SERVICE PROVIDER TO COMPILE STANDARD TENDER DOCUMENTS FOR MAGALIES WATER (SERVICE AND SUPPLY AND DELIVERY DOCUMENTS)

RFQ – REQUEST FOR QUOTATION TO CONDUCT OCCUPATIONAL HAZARDOUS CHEMICAL AGENT SURVEY AT GANYESA DISTRICT, SCHWEIZER RENEKE WTW, PUDIMOE WTW, TAUNG WTW, HARTSWATER WORKSHOP, KGOMOTSO WTW, BLOEMHOF WTW, BLOEMHOF WWTW, CHRISTIANA WTW, LEEUDORINGSTAD, AND CHRISTIANA WWTW

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF POLLY DOSING PUM

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF WHEELIE WASTE BINS AND THE SIZE MUST BE 240L AND CHAIN THEM ON THE WALL WITH CHAIN AND HOOKS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVER WINDSOCKS FOR AREA EAST, AREA WEST, FAR WEST AND SOUTHWEST PLANTS

RFQ – REQUEST FOR QUOTATION FOR ANNUAL SERVICE OF FIRE EXTINGUISHERS AT VAALKOP

RFQ – REQUEST FOR QUOTATION FOR EMPTYING OF SEPTIC TANK AT MAGALIES WATER PLANTS FOR 6 MONTHS

RFQ – REQUEST FOR QUOTATION FOR EMPTYING OF SEPTIC TANK AT MAGALIES WATER PLANTS FOR 6 MONTHS AT SOUTH WEST

RFQ – REQUEST FOR QUOTATION FOR REMOVAL OF 10 HECTARES PERSICARIA SENEGALENSIS

RFQ – REQUEST FOR QUOTATION FOR MAGALIES WATER HARTBEESPOORT DAM REHABILITATION PROJECT ANNUAL REPORT

RFQ – REQUEST FOR QUOTATION FOR NAVY BLUE DRIMACS FOR SCHOOL KIDS

RFQ – REQUEST FOR QUOTATION FOR STATUTORY INSPECTION ON LIFTS

RFQ – REQUEST FOR QUOTATION FOR REPLACING PROTECTION RELAY

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF BEARINGS

RFQ – REQUEST FOR QUOTATION FOR THE INSPECTION OF MOTOR SERVICES

RFQ – REQUEST FOR QUOTATION FOR THE APPOINTMENT A PROFESSIONAL SERVICE PROVIDER TO CONDUCT AN ASSESSMENT AND PROVIDE A REPORT THAT WILL SERVE AS AN ADVISORY TOWARDS AN EEFFICIENT AND EFFECTIVE SECURITY SERVICES

RFQ – REQUEST FOR QUOTATION FOR APPOINTMENT OF A PROFESSIONAL SERVICE PROVIDER (PSP) TO ASSIST WITH THE DEVELOPMENT AND FINALIZATION OF THE ORGANIZATIONAL STRUCTURE FOR MAGALIES WATER

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVER PROGRAMMING OF HYTERA HP505 G VHF HANDHELD RADIO

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVER DIESEL TANKER

RFQ – REQUEST FOR QUOTATION FOR MAGALIES WATER SPORTS UNIFORM RFQ – 10025694

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVER PUMP AND MOTOR

RFQ – REQUEST FOR QUOTATION FOR SUPPLY, DELIVERY, CHLORINE EQUIPMENT SERVICE

RFQ – REQUEST FOR QUOTATION FOR SUPPLY, DELIVERY, AND INSTALLATION OF SEPTIC TANK

RFQ – REQUEST FOR QUOTATION FOR LOAD TEST ON SOUTH-WEST OVERHEAD CRANES

RFQ – REQUEST FOR QUOTATION FOR MAINTENANCE AND SERVICING OF ELECTRONIC SECURITY SYSTEM (ESS) AT VARIOUS MAGALIES WATER SITES

RFQ – REQUEST FOR QUOTATION FOR PIPE STEEL 150MM RFQ 10025685

RFQ – REQUEST FOR QUOTATION FOR PIPE 350MM PN25 FUSION BOND RFQ 10025684

RFQ – REQUEST FOR QUOTATION FOR PIPE STEEL RFQ 10025683

RFQ – REQUEST FOR QUOTATION FOR VAGAPULS 11 8M RADAR LEVEL RFQ 10025675

RFQ – REQUEST FOR QUOTATION FOR BRANDED BOTTLED WATER

RFQ – REQUEST FOR QUOTATION FOR DEKABON INSTRUMENT CABLE

RFQ – REQUEST FOR QUOTATION FOR SWA PVC COPER CABLE 2.5MM 2X4 CORE

RFQ – REQUEST FOR QUOTATION FOR IFM PN3092 (BSP) G 1 4 THREAD M12

RFQ – REQUEST FOR QUOTATION FOR SWA PVC COPER CABLE 70MM X 4 CORE

RFQ – REQUEST FOR QUOTATION FOR EMPTYING OF SEPTIC TANK AT MAGALIES WATER SOUTH WEST PLANTS FOR 6 MONTHS

RFQ – REQUEST FOR QUOTATION FOR EMPTYING OF SEPTIC TANK AT MAGALIES WATER FAR WEST PLANTS FOR 6 MONTHS

RFQ – REQUEST FOR QUOTATION FOR EMPTYING OF SEPTIC TANK AT MAGALIES WATER FAR WEST PLANTS FOR 6 MONTHS

RFQ – REQUEST FOR QUOTATION FOR EMPTYING OF SEPTIC TANK AT MAGALIES WATER CULLINAN PLANT FOR 6 MONTHS

RFQ – REQUEST FOR QUOTATION FOR EMPTYING OF SEPTIC TANK AT MAGALIES WATER PLANTS FOR 6 MONTHS

RFQ – REQUEST FOR QUOTATION FOR REPLACEMENT OF ROOF CEILING INSIDE PLANT 1

RFQ – REQUEST FOR QUOTATION FOR REPLACE PS3 CHLORINE DOORS

RFQ – REQUEST FOR QUOTATION FOR NETWORK MONITORING TOOL FOR 36 MONTHS

RFQ – REQUEST FOR QUOTATION FOR SCCM MAINTENANCE AND SUPPORT

RFQ – REQUEST FOR QUOTATION FOR IMESA STAND

RFQ – REQUEST FOR QUOTATION FOR TURBIDITY FORMAZIN CALIBRATION

RFQ – REQUEST FOR QUOTATION FOR TURBIDITY CALIBRATION

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVER OFFICE EQUIPMENT

RFQ – REQUEST FOR QUOTATION FORSUPPLY AND DELIVER OFFICE FURNITURE AT MAQUASSI HILL

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALL CONCRETE RESERVOIRS MECHANICAL LEVEL INDICATORS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVER COMPRESSOR SPARES

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVER APOLLO LIGHTS SPARES

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF DDA 30-4 AR (GRUNDFOS) POLLY DOSING PUMP

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY MANHOLES METERS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY CHLORINE SENSORS

RFQ – REQUEST FOR QUOTATION FOR RFQ 10024820

RFQ – REQUEST FOR QUOTATION FOR RFQ 10024396

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY TORCHES FOR THE STANDBY PERSONNEL AT FAR WEST REGION

RFQ – REQUEST FOR QUOTATION FOR GEN-PRESSURE FEED CHLORINATOR

RFQ – REQUEST FOR QUOTATION FOR DPD PILLOWS

RFQ – REQUEST FOR QUOTATION FOR ACTUATOR REPAIR

RFQ – REQUEST FOR QUOTATION FOR LOG BOOKS

RFQ – REQUEST FOR QUOTATION FOR DISTRIBUTION PIPELINE LEAK REPAIRS

RFQ – REQUEST FOR QUOTATION FOR REMOVAL OF WASTE LIQUID WITH HONEY SUCKER

RFQ – REQUEST FOR QUOTATION FOR MANUFACTURE AND SUPPLY KNIFE VALVE BRASS NUT

RFQ – REQUEST FOR QUOTATION FOR ALTITUDE CONTROL VALVE

RFQ – REQUEST FOR QUOTATION FOR SERVICE LAB INSTRUMENTS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALL COMPRESSOR

RFQ – REQUEST FOR QUOTATION FOR SUPPLYING ULTRASONIC LEVEL SENSOR

RFQ – REQUEST FOR QUOTATION FOR SUPPLYING NETWORK SWITCH

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALL A DSTV DECODER

RFQ – REQUEST FOR QUOTATION FOR MEDIA TOOLS

RFQ – REQUEST FOR QUOTATION FOR PR 10024943-REQUEST

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALL ELECTRICAL CAPACITOR

RFQ – REQUEST FOR QUOTATION FOR PR 10024382 MHI

RFQ – REQUEST FOR QUOTATION FOR STATUTORY INSPECTION ON LIFTS

RFQ – REQUEST FOR QUOTATION FOR 2D MOTOR REPLACE PROTECTION RELAY

RFQ – REQUEST FOR QUOTATION FOR PR 10025304 AUDITS

RFQ – REQUEST FOR QUOTATION FOR REPAIR CRACKED CONCRETE

RFQ – REQUEST FOR QUOTATION FOR DOSING PUMP GRUNDFOS

RFQ – REQUEST FOR QUOTATION FOR SUPPY AND DELIVERY OF WEG SMART RELAY

RFQ – REQUEST FOR QUOTATION FOR REPAIRING LAPA TRIE OVERFLOW PIPE INSIDE THE RESERVOIRS

RFQ – REQUEST FOR QUOTATION FOR VSD-SERVICE

RFQ – REQUEST FOR QUOTATION FOR STORM-WATER

RFQ – REQUEST FOR QUOTATION FOR SEWER-CONNECTION

RFQ – REQUEST FOR QUOTATION FOR REPAIR-FIBRE

RFQ – REQUEST FOR QUOTATION FOR RECOVERY-PUMP

RFQ – REQUEST FOR QUOTATION FOR HIGH-LIFT-SPARES

RFQ – REQUEST FOR QUOTATION FOR GRASS-CUTTING-EQUIPMENT

RFQ – REQUEST FOR QUOTATION FOR EXTRACTOR-FAN

RFQ – REQUEST FOR QUOTATION FOR CULLINAN-CLARIFIER-SUMP

RFQ – REQUEST FOR QUOTATION FOR CONTROL-VALVE

RFQ – REQUEST FOR QUOTATION FOR CLEAR-WATER-SUMP

RFQ – REQUEST FOR QUOTATION FOR CLEANING-DRY-BEDS

RFQ – REQUEST FOR QUOTATION FOR BLOWER-SENSOR

RFQ – REQUEST FOR QUOTATION FOR AIR-VALVES

RFQ – REQUEST FOR QUOTATION FOR APPOINTMENT OF EXTERNAL EXPERT TO ASSESS PROCUREMENT BOTTLENECKS AND RECOMMEND LONG- TERM SOLUTIONS FOR SOURCING POLYMERIC COAGULANTS

RFQ – REQUEST FOR QUOTATION FOR VSD FAN

RFQ – REQUEST FOR QUOTATION FOR PAC SYSTEM

RFQ – REQUEST FOR QUOTATION FOR LOCK OUT LOCKS

RFQ – REQUEST FOR QUOTATION FOR LIME MIXER MOTOR

RFQ – REQUEST FOR QUOTATION FOR APPOINTMENT OF CUSTOMER RELATIONSHIP MANAGEMENT

RFQ – REQUEST FOR QUOTATION FOR APPOINTMENT OF EXTERNAL EXPERT TO ASSESS PROCUREMENT BOTTLENECKS AND RECOMMEND LONG- TERM SOLUTIONS FOR SOURCING POLYMERIC COAGULANTS

RFQ – REQUEST FOR QUOTATION FOR MAGALIES WATER ANNUAL REPORT 24/25

RFQ – REQUEST FOR QUOTATION FOR APPOINT A SECURITY SERVICE PROVIDER FOR THE PROVISIONING OF GUARDING SECURITY SERVICES FOR ROOIGROND WASTE WATER TREATMENT PLANT FOR A PERIOD OF FOUR MONTHS

RFQ – REQUEST FOR QUOTATION FOR APPOINTMENT OF EXTERNAL EXPERT TO ASSESS PROCUREMENT

RFQ – REQUEST FOR QUOTATION FOR NATIONAL YOUTH INDABA EXHIBITION STAND

RFQ – REQUEST FOR QUOTATION FOR GIFT COMBO

RFQ – REQUEST FOR QUOTATION FOR PROMOTIONAL ITEMS

RFQ – REQUEST FOR QUOTATION FOR BRANDED MAGALIES WATER EXECUTIVE LAPTOP BAGS X 50

RFQ – REQUEST FOR QUOTATION FOR BACKUP TAPE DRIVE

RFQ – REQUEST FOR QUOTATION FOR REPLACE 2.5 KM PIPELINE IN PHAPOSANE

RFQ – REQUEST FOR QUOTATION FOR SERVICE KIT

RFQ – REQUEST FOR QUOTATION FOR REPLACE BACKWASH VALVE

RFQ – REQUEST FOR QUOTATION FOR REPAIR SLUICE GATE

RFQ – REQUEST FOR QUOTATION FOR REPAIR RECOVERY PUMPS

RFQ – REQUEST FOR QUOTATION FOR REPAIR PUMPS

RFQ – REQUEST FOR QUOTATION FOR REPAIR POLY PUMPS

RFQ – REQUEST FOR QUOTATION FOR REPAIR GEARBOX

RFQ – REQUEST FOR QUOTATION FOR REPAIR BRUSHCUTTER

RFQ – REQUEST FOR QUOTATION FOR RECOVERY PUMP

RFQ – REQUEST FOR QUOTATION FOR REAPAIR VALVES

RFQ – REQUEST FOR QUOTATION FOR HIGH LIFT SPARES

RFQ – REQUEST FOR QUOTATION FOR INSTALL AND COMMISSION A BATTERY EXPANSION FOR A SCHNEIDER ELECTRIC 40KVA UPS

RFQ – REQUEST FOR QUOTATION FOR REPAIR SSE TELEMETRY FOR KORTBEGRIP, MONAKOTA, EVERGREEN & SPITSKOP RESERVIORS

RFQ – REQUEST FOR QUOTATION FOR PERFORM ON-SITE PUMP EFFICIENCY TEST

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALL PLANT 2 REPLACEMENT DAFF VALVES UNITS

RFQ – REQUEST FOR QUOTATION FOR REPLACEMENT OF PLANT 1 VALVE WORM GEARBOXES

RFQ – REQUEST FOR QUOTATION FOR MANUFACTURE AND SUPPLY KNIFE VALVE BRASS NUT

RFQ – REQUEST FOR QUOTATION FOR ONLINE ANALYSER INSTALLATION

RFQ – REQUEST FOR QUOTATION FOR PLC

RFQ – REQUEST FOR QUOTATION FOR ELECTRICAL TOOLS

RFQ – REQUEST FOR QUOTATION FOR PROXIMITY SWITCHES

RFQ – REQUEST FOR QUOTATION FOR REFURBISH STAFF QUARTERS

RFQ – REQUEST FOR QUOTATION FOR REPAIR ROOF

RFQ – REQUEST FOR QUOTATION FOR RESTORE TELEMETRY

RFQ – REQUEST FOR QUOTATION FOR REWIRE PANEL

RFQ – REQUEST FOR QUOTATION FOR SEWER CONNECTION

RFQ – REQUEST FOR QUOTATION FOR TELEMETRY

RFQ – REQUEST FOR QUOTATION FOR AIR VALVES

RFQ – REQUEST FOR QUOTATION FOR CLEANING CLARIFIER

RFQ – REQUEST FOR QUOTATION FOR CLEANING CLEAR WATER SUMP

RFQ – REQUEST FOR QUOTATION FOR DRY BED

RFQ – REQUEST FOR QUOTATION FOR CLEANING RECOVERY

RFQ – REQUEST FOR QUOTATION FOR CHLORINATION SYSTEM

RFQ – REQUEST FOR QUOTATION FOR COMMUNICATION RADIO

RFQ – REQUEST FOR QUOTATION FOR FLOW SENSOR

RFQ – REQUEST FOR QUOTATION FOR LOG BOOKS

RFQ – REQUEST FOR QUOTATION FOR POWER BEANS

RFQ – REQUEST FOR QUOTATION FOR REPAIR BREAKER

RFQ – REQUEST FOR QUOTATION FOR REPLACE UPS

RFQ – REQUEST FOR QUOTATION FOR REPLACE VSD

RFQ – REQUEST FOR QUOTATION FOR SUPPLY TOOL TRAILER

RFQ – REQUEST FOR QUOTATION FOR SUPPLY TOOLS AND EQUIPMENT

RFQ – REQUEST FOR QUOTATION FOR VULNERABILITY ASSESSMENT AND PENETRATION TESTING

RFQ – REQUEST FOR QUOTATION FOR DISCLOSURE FOR THE ANNUAL FINANCIAL STATEMENTS TO ENSURE COMPLIANCE TO GRAP STANDARDS (EMPLOYEE BENEFITS) FOR A PERIOD OF THREE (3) YEARS

RFQ – REQUEST FOR QUOTATION FOR CONDUCTIVITY METER

RFQ – REQUEST FOR QUOTATION FOR LIME MIXING DRUM

RFQ – REQUEST FOR QUOTATION FOR LOWBED TRAILER 2

RFQ – REQUEST FOR QUOTATION FOR LOWBED TRAILER

RFQ – REQUEST FOR QUOTATION FOR MONITORING EQUIPMENT

RFQ – REQUEST FOR QUOTATION FOR AERATOR ARM

RFQ – REQUEST FOR QUOTATION FOR CHLORINE KIT

RFQ – REQUEST FOR QUOTATION FOR BOREHOLE TESTING

RFQ – REQUEST FOR QUOTATION FOR HAZARDOUS BIOLOGICAL AGENTS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY OF FIRST AID REFILL

RFQ – REQUEST FOR QUOTATION FOR STATUTORY INSPECTIONS STRUCTURAL TEST

RFQ – REQUEST FOR QUOTATION FOR REPLACE GANYESA OFFICES FLOOR CARPETS WITH TILES OR EQUIVALENT FLOOR MATERIAL

RFQ – REQUEST FOR QUOTATION FOR CHRISTIANA GENERATOR SERVICE

RFQ – REQUEST FOR QUOTATION FOR SUPPLY PUMPS AND MOTORS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY SUPPLY AN OFFICE CONTAINER

RFQ – REQUEST FOR QUOTATION FOR SUPPLY CHRISTIANA LEVEL CONTROL VALVE

RFQ – REQUEST FOR QUOTATION FOR MODULE 1 FILTER MEDIA REPLENISHMENT

RFQ – REQUEST FOR QUOTATION FOR REPAIR PLANT 2 HLPS CONTROL, SUPERNATANT PUMP STATION CONTROL, INDUSTRIAL NETWORK AND INSTALL & CONFIGURE ELECTRICAL PROTECTION & CONTROL RELAYS FOR SUMP PUMPS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY, INSTALL AND COMMISSION PLANT 2D MV CIRCUIT BREAKERS AND MEDIUM VOLTAGE SWITCHGEAR REPAIRS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY, INSTALL AND COMMISSION TWO BATTERY TRIPPING UNIT FOR MAIN SUBSTATION

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVER PVC SAFETY SHOWER

RFQ – REQUEST FOR QUOTATION FOR SUPPLY, INSTALL AND COMMISSIONING OF ELECTRICAL ACTUATORS FOR PLANT 3 COCODAFF

RFQ – REQUEST FOR QUOTATION FOR MENS MAVERICK JACKET

RFQ – REQUEST FOR QUOTATION FOR HEADHUNTING-SAP BASIS SPECIALIST

RFQ – REQUEST FOR QUOTATION FOR RISK MATURITY ASSESSMENT

RFQ – REQUEST FOR QUOTATION FOR SUPPLY OF ELECTRICIAN TOOLS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY OF MECHANICAL TOOLS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY WORKSHOP SPECIAL TOOLS

RFQ – REQUEST FOR QUOTATION FOR DOSING PUMP GRUNDFOS DDA 30-N

RFQ – REQUEST FOR QUOTATION FOR SUPPLY SWITCHES

RFQ – REQUEST FOR QUOTATION FOR SERVICE BLOWER

RFQ – REQUEST FOR QUOTATION FOR SERVICE AND REPAIR BRUSH CUTTER

RFQ – REQUEST FOR QUOTATION FOR REWIND MOTOR

RFQ – REQUEST FOR QUOTATION FOR PLC REPAIR

RFQ – REQUEST FOR QUOTATION FOR PANEL REPAIR

RFQ – REQUEST FOR QUOTATION FOR BLOWER REPAIR

RFQ – REQUEST FOR QUOTATION FOR NDT ON SATURATOR TANKS

RFQ – REQUEST FOR QUOTATION FOR NDT LIFTING EQUIPMENT

RFQ – REQUEST FOR QUOTATION FOR INSTALL INSTRUMENTS

RFQ – REQUEST FOR QUOTATION FOR HIRE GRADER

RFQ – REQUEST FOR QUOTATION FOR GEARBOX

RFQ – REQUEST FOR QUOTATION FOR BOOSTER PUMP

RFQ – REQUEST FOR QUOTATION FOR BOOSTER PUMP

RFQ – REQUEST FOR QUOTATION FOR ALIGN AERATOR ARM

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF MONITRAN INDUSTRIAL ACCELEROMETER

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF ELECTRICAL MATERIAL

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF FUSE ISOLATOR

RFQ – REQUEST FOR QUOTATION FOR SUPPLY STANDARDS AND PERFORM CALIBRATIONS

RFQ – REQUEST FOR QUOTATION FOR REPLACEMENT OF BOSPOORT VALVE

RFQ – REQUEST FOR QUOTATION FOR PR 10023988 - WAR ON LEAKS MOSES KOTANE STUDY

RFQ – REQUEST FOR QUOTATION FOR BELA BELA WTW WATER QUALITY EQUIPMENTS AND MONITORING SYSTEMS

RFQ – REQUEST FOR QUOTATION TO APPOINT A SECURITY SERVICE PROVIDER FOR THE PROVISIONING OF GUARDING SECURITY SERVICES FOR MAQUASSI HILLS MAGALIES WATER INFRASTRUCTURE FOR A PERIOD OF ONE MONTH

RFQ – REQUEST FOR QUOTATION FOR IPADS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY 4 OFF KSB SUBMISSIBLE PUMPS

RFQ – REQUEST FOR QUOTATION FOR REPAIR OF PLANT 3 HIGHLIFT MOTORS

RFQ – REQUEST FOR QUOTATION FOR REPLACEMENT OF PLANT 3 GOOSE NECKS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY LINE FASTERNERS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY SDS 400-500 CRITICAL SPARES

RFQ – REQUEST FOR QUOTATION FOR SUPPLY SCAFFOLDING EQUIPMENT

RFQ – RE-ADVERT REQUEST FOR QUOTATION FOR TRANSFORMERS FOR MAKWASI HILLS BOREHOLES

RFQ – REQUEST FOR QUOTATION FOR HPDE PIPES

RFQ – REQUEST FOR QUOTATION FOR CHLORINE PIPES

RFQ – REQUEST FOR QUOTATION FOR REFURBISHMENT OF PLANT AND BUILDING

RFQ – REQUEST FOR QUOTATION FOR BUILDING PORTAL FRAME

RFQ – REQUEST FOR QUOTATION FOR ETB 040 - 025 – 200 PUMP

RFQ – REQUEST FOR QUOTATION FOR REBUILDING PUMP CONCRET BASE & ALIGN PUMP LINES

RFQ – REQUEST FOR QUOTATION FOR VSD REPAIR

RFQ – REQUEST FOR QUOTATION FOR KSB PUMP

RFQ – REQUEST FOR QUOTATION FOR UNDERGROUND DETECTOR

RFQ – REQUEST FOR QUOTATION FOR PRESSURE TESTER

RFQ – REQUEST FOR QUOTATION FOR POLY PIPES

RFQ – REQUEST FOR QUOTATION FOR NOZZLES

RFQ – REQUEST FOR QUOTATION FOR CAMERA ACCESSORIES

RFQ – REQUEST FOR QUOTATION FOR VANELLUS C6 CLASSIC S.A.E.15W/40 20/25

RFQ – REQUEST FOR QUOTATION FOR INSTALLATION OF DATA LINE FOR TSWASA WATER SCHEME

RFQ – REQUEST FOR QUOTATION FOR SUPPLY, DELIVERY AND INSTALLATION IN THE SERVER ROOM

RFQ – REQUEST FOR QUOTATION FOR MODULE 3 DAF UNIT REPAIRS

RFQ – REQUEST FOR QUOTATION FOR DIESEL ENGINE OIL 25L

RFQ – RE-ADVERT REQUEST FOR QUOTATION FOR SUPPLY GARDEN SERVICE TO VAALKOP PLANT

RFQ – REQUEST FOR QUOTATION FOR VERIFICATION OF VAALKOP WTW ELECTRONIC FLOWMETERS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY, INSTALL AND COMMISSION CORDONAL FLOW METERS

RFQ – REQUEST FOR QUOTATION FOR SERVICE GOWERMANSPLAAS ALTITUTE PRESSURE CONTROL VALVE (PRV)

RFQ – REQUEST FOR QUOTATION FOR IMPLEMENTATION OF THE LEARNERSHIP PROGRAMME

RFQ – REQUEST FOR QUOTATION FOR A SOFT STARTER INTERFACE

RFQ – REQUEST FOR QUOTATION FOR KOSHINI TRASH PUMP

RFQ – REQUEST FOR QUOTATION FOR SUPPLY FOUR LOW VOLTAGE INDUCTION MOTORS FOR SUPERNATANT PUMP STATION

RFQ – REQUEST FOR QUOTATION FOR VERIFICATION OF VAALKOP WTW ELECTRONIC FLOWMETERS

RFQ – REQUEST FOR QUOTATION FOR CONDUCT WATER USE LICENSE (WUL) EXTERNAL AUDIT AND PROVIDE A DETAILED AUDIT REPORT

RFQ – REQUEST FOR QUOTATION FOR CLEANING SLUDGE UNITS

RFQ – REQUEST FOR QUOTATION FOR REPAIRING A COMPRESSOR

RFQ – REQUEST FOR QUOTATION FOR REPLACING CHAINS

RFQ – REQUEST FOR QUOTATION FOR SHOWER VALVE

RFQ – REQUEST FOR QUOTATION FOR NON RETURN VALVE

RFQ – REQUEST FOR QUOTATION FOR LAWNMOWER REPAIR AND SERVICE

RFQ – REQUEST FOR QUOTATION FOR COMPRESSOR OVERHAUL

RFQ – REQUEST FOR QUOTATION FOR STRUCTURAL INTERGITY

RFQ – REQUEST FOR QUOTATION FOR TRANSFORMERS FOR MAKWASI HILLS BOREHOLES

RFQ – REQUEST FOR QUOTATION FOR 200 SERIES MULTIRANGER

RFQ – REQUEST FOR QUOTATION FOR SERVICE GOWERMANSPLAAS ALTITUTE PRESSURE CONTROL VALVE

RFQ – REQUEST FOR QUOTATION FOR INSTALLATION OF DISTRIBUTION BALANCE METERS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALL 100 MANHOLE COVERS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVER HEAVY DUTY TOOLS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVER MESH FENCE WITH POLES

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVER FIBREGLASS GRATINGS CLASS 1 X 30

RFQ – REQUEST FOR QUOTATION FOR CONSTRUCTION OF MANHOLES

RFQ – REQUEST FOR QUOTATION FOR SUPPLY GARDEN SERVICE TO MAGALIES WATER VAALKOP PLANT

RFQ – REQUEST FOR QUOTATION FOR SUPPLY OF 200MM ALTITUDE CONTROL VALVE

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF TOOLS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF COMPRESSOR AND OTHER PNEUMATIC TOOLS

RFQ – REQUEST FOR QUOTATION FOR STRUCTURAL INTEGRITY INSPECTION OF ALL PLANTS

RFQ – REQUEST FOR QUOTATION FOR REPLACEMENT OF THE WALLMANSTHAL AC ROOF AT THE PLANT

RFQ – REQUEST FOR QUOTATION FOR REFURBISHMENT OF STAFF QUARTERS AT WALLMANSTHAL

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF PUMPS FOR OPERATION AND MAINTENANCE

RFQ – REQUEST FOR QUOTATION FOR PLANT HIRE AND EQUIPMENT FOR THE GENERAL MAINTENACE

RFQ – REQUEST FOR QUOTATION FOR DAF UNIT PUDIMOE REPAIR

RFQ – REQUEST FOR QUOTATION FOR JACK HAMMER SUPPLY

RFQ – REQUEST FOR QUOTATION FOR CHLORINE PIPE

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF CUTTING DISC AND WELDING ROD

RFQ – REQUEST FOR QUOTATION FOR TRANSFORMER OIL TESTS

RFQ – REQUEST FOR QUOTATION FOR SERVICE CHLORINE DOSING SYSTEM

RFQ – REQUEST FOR QUOTATION FOR ASSESSMENT AND SERVICE OF X2 AIR BLOWER ASSESS THE CONDITION OF THE BLOWER

RFQ – REQUEST FOR QUOTATION FOR REPAIR AND SERVICE ATLAS COPCO BLOWER

RFQ – REQUEST FOR QUOTATION FOR REPLACE X2 FAULTY GEARBOX. SUPPLY AND DELIVER X2 NEW BUTERFLY VALVE GEARBOX TO REPLACE THE FAULTY GEARBOXES

RFQ – REQUEST FOR QUOTATION FOR REPAIR WALLMANSTHALE RES VSD REPAIR AND RESTORE

RFQ – REQUEST FOR QUOTATION FOR PLANT ASSESMENT FOR IP ADRESSES PLC PLANT ASSESMENT AND DOCUMENTING IP ADRESSES FOR ALL THE PLC'S SPECIFICATION

RFQ – REQUEST FOR QUOTATION FOR REGISTERING & COMMISSIONING ROCKWELL VSD 3 KLP INSERT PARAMETERS & TEST

RFQ – REQUEST FOR QUOTATION FOR TRUSH PUMP SUPPLY

RFQ – REQUEST FOR QUOTATION FOR PROCUREMENT OF TILES TO REPLACE WORN OUT CARPETS AT GANYESA OFFICE FLOORS

RFQ – REQUEST FOR QUOTATION FOR REPAIR OF CHLORINATION SYSTEM

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALL 100 MANHOLE COVERS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALLATION OF DISTRIBUTION BALANCE METERS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY OF SCAFFOLDING EQUIPMENT

RFQ – REQUEST FOR QUOTATION FOR REPAIRS OF 2100Q EQUIPMENT

RFQ – REQUEST FOR QUOTATION FOR SODIUM HYPOCHLORITE SOL PURITY 12-15% 1000L

RFQ – REQUEST FOR QUOTATION FOR REPAIRING A 6 SPEED JAR STIRRER

RFQ – REQUEST FOR QUOTATION FOR POLYMER ZF 2783

RFQ – REQUEST FOR QUOTATION FOR POLYMER 5456XI

RFQ – REQUEST FOR QUOTATION FOR PUDUMOE MODULE 3 MOTORS

RFQ – REQUEST FOR QUOTATION FOR REPAIR 2 BERMAID VALVES AND SUPPLY 2 LIM

RFQ – REQUEST FOR QUOTATION FOR REPAIR TO DAF UNIT/RECONFIGURATION

RFQ – REQUEST FOR QUOTATION FOR APPOINTMENT TO PROCURE AND INSTALLATION OF ASSOCIATED EQUIPMENTS FOR THE WATER QUALITY TREATMENT AND FOR BELA BELA LM WATER TREATMENT PLANT

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF CASCADE CLAMPS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF SERVICE KIT

RFQ – REQUEST FOR QUOTATION FOR COMPREHENSIVE PROCESS AUDITS AT AREA EAST

RFQ – REQUEST FOR QUOTATION FOR COMPREHENSIVE PROCESS AUDITS AT AREA WEST

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF AIR RELEASE VALVE

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND DELIVERY OF OILS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALL AN ISO APPROVED FULL LIFEBUOY OR LIFE RING KIT

RFQ – REQUEST FOR QUOTATION FOR REFURBISHING NO1 SAND FILTERS ARCHIMEDIAN SCREW PUMP AS PER ATTACHED SCOPE OF WORK

RFQ – REQUEST FOR QUOTATION FOR CONDUCT EXIT MEDICAL SURVEILLANCE FOR 19 EMPLOYEES

RFQ – REQUEST FOR QUOTATION FOR OCCUPATIONAL HYGIENE SURVEY AT FAR WEST AND SOUTH WEST

RFQ – REQUEST FOR QUOTATION FOR PEST CONTROL SERVICES ARE REQUIRED FOR 24 MONTHS

RFQ – REQUEST FOR QUOTATION FOR POLYMER BULK SUPPLY

RFQ – REQUEST FOR QUOTATION FOR SODIUM HYPOCHLORITE SOL.PURITY 12-15% SUPPLY

RFQ – REQUEST FOR QUOTATION FOR POLYMER BULKSOL.PURITY 12-15% SUPPLY

RFQ – REQUEST FOR QUOTATION FOR BOREHOLE TESTING

RFQ – REQUEST FOR QUOTATION FOR REGISTERING & COMMISSIONING OF ROCKWELL VSD

RFQ – REQUEST FOR QUOTATION FOR REPLACEMENT OF 2 FAULTY GEARBOX

RFQ – REQUEST FOR QUOTATION FOR PLANT ASSESMENT

RFQ – REQUEST FOR QUOTATION FOR POWER SUPPLY

RFQ – REQUEST FOR QUOTATION FOR PUMP REFURBISH

RFQ – REQUEST FOR QUOTATION FOR REINFORCE 2T CRANE SUPPLY

RFQ – REQUEST FOR QUOTATION FOR TANK STAND REPAIR

RFQ – REQUEST FOR QUOTATION FOR SERVICE BLOWER SUPPLY

RFQ – REQUEST FOR QUOTATION FOR SUPPLY AND INSTALL PUMPS

RFQ – REQUEST FOR QUOTATION FOR WORKSHOP TOOLS

RFQ – REQUEST FOR QUOTATION FOR CHLORINE ROOM CRANE & BEAM

RFQ – REQUEST FOR QUOTATION FOR LIME MIXING MOTOR

RFQ – REQUEST FOR QUOTATION FOR BTU REPAIR

RFQ – REQUEST FOR QUOTATION FOR PIPE MATERIAL

RFQ – REQUEST FOR QUOTATION FOR LOCK OUT LOCKS

RFQ – REQUEST FOR QUOTATION FOR REPAIR BLOWER

RFQ – REQUEST FOR QUOTATION FOR PRESSURE TEST

RFQ – REQUEST FOR QUOTATION FOR TOOLS

RFQ – REQUEST FOR QUOTATION FOR VSD REPAIR

RFQ – REQUEST FOR QUOTATION FOR TRANSFORMER REPAIR

RFQ – REQUEST FOR QUOTATION FOR CAMARA ACCESSORIES

RFQ – REQUEST FOR QUOTATION FOR 22KV BTU REPAIR

RFQ – REQUEST FOR QUOTATION FOR TRANSFORMER OIL TESTING

RFQ – REQUEST FOR QUOTATION FOR FLOW METRICS

RFQ – REQUEST FOR QUOTATION FOR DETECTORS

RFQ – REQUEST FOR QUOTATION FOR CLEANING RECOVERY UNITS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY REPLACEMENT RECYCLE PUMPS

RFQ – REQUEST FOR QUOTATION FOR REPLACEMENT BACKWASH PUMPS

RFQ – REQUEST FOR QUOTATION FOR SUPPLY, INSTALL & COMMISSIONING COMPLETE PISTON COMPRESSORS

RFQ – REQUEST FOR QUOTATION FOR STEEL PIPES

RFQ – REQUEST FOR QUOTATION FOR PRESSURE VESSELS STATUTORY INSPECTION

RFQ – REQUEST FOR QUOTATION TO APPOINT A SECURITY SERVICE PROVIDER FOR THE PROVISIONING OF GUARDING SECURITY SERVICES FOR MAQUASSI HILLS MAGALIES WATER INFRASTRUCTURE FOR A PERIOD OF TWO MONTHS

RFQ – MAINTENANCE AND SERVICING OF ELECTRONIC SECURITY SYSTEM (ESS) AT ALL MAGALIES WATER SITES

RFQ – REQUEST FOR CONSULTANCY SERVICES - MAGALIES WATER ORGANISATIONAL STRATEGY

RFQ – 100 – W – 2620 – WAR ON LEAKS MOSES KOTANE

RFQ – LEARNEERSHIP

RFQ – PR – 10023217

RFQ – MAQUASSI HILLS

RFQ – REPAIR MAIN SUBSTATION MEDIUM VOLTAGE (MV) RAW WATER FEEDER

RFQ – FABRICATE AND SUPPLY MOTOR COOLING WATER PIPE

RFQ – SERVICE OF HEAD OFFICE AND BRITS GENERATOR

RFQ – WORKSHOP MACHINES VAALKOP

RFQ – FORENSIC INVESTIGATION

RFQ – WELLNESS

RFQ – REPAIR MAIN SUBSTATION MEDIUM VOLTAGE (MV) RAW WATER FEEDER

RFQ – REPAIR-3-VAALKOP-WTW-DISTRIBUTION-TELEMETRY-STATIONS- RFQ-MANUAL EXTENSION

RFQ- WAR ON LEAKS MOSES KOTANE

RFQ VALUATION OF FIXED PROPERTY

RFQ WAR-ON-LEAKS PROJECT TAUNG

RFQ INSTALLATION OF FLOW METERS

RFQ-10020748 CROWD MANAGEMENT FEB 2024

ANNEXURE A PRICING SCHEDULE RFQ 10020748 CROWD MANAGEMENT FEB 2024

RFQ WHISTLE BLOWER

TOR HOTLINE (002) (004)

RFQ – PSP MOSES KOTANE

RFQ – DITSOBOTLA BOREHOLE CONTRACTOR

RRFQ-10021132: APPOINTMENT OF A CONTRACTOR FOR DRILLING AND EQUIPPING A BOREHOLE AT MORETELE FIRE STATION, IN MAKAPANSTAD.

RRFQ-10021000: APPOINTMENT OF A CONTRACTOR FOR DRILLING AND EQUIPPING OF BOREHOLES IN MORETELE LOCAL MUNICIPALITY AT SWARTDAM AND MMOTI VILLAGES.

RFQ – 10021135: BLOEMHOF WASTE WATER TREATMENT PLANT FENCE REPAIRS

FINAL REQUEST FOR QUOTE STRATEGY SESSION

RFQ 10021047: PSP FOR THE FIRE SUPPRESSION PROJECT

RFQ 10020954: PROFESSIONAL SERVICE PROVIDER TO CARRY OUT A COMPREHENSIVE PROCESS AUDIT

RFQ 10020837: CONDUCT DYE TEST OF CLEAR WATER TANKS

RFQ 10021135: SECURITY MEASURES – BLOEMHOF WWTP

RFQ 10020915: HDPE CUTTING EXACT PIPE CUT 460 & TRAINING

RFQ 10019269: SERVICE 5 GENERATORS AT BRUSSELS PUMP SET

RFQ 10021075: INSTALL BARRIER LINES

RFQ 10021000: APPOINTMENT OF A CONTRACTOR FOR DRILLING AND EQUIPPING OF BOREHOLES IN MORETELE LOCAL MUNICIPALITY AT SWARTDAM AND MMOTI VILLAGES

RFQ 10021002: APPOINTMENT OF A CONTRACTOR FOR THE GROUND WATER AUGMENTATION PROJECTS. WHICH ENTAIL DRILLING AND EQUIPPING OF BOREHOLES IN RUSTENBURG LOCAL MUNICIPALITY AT SERALENG (NKANDLA), MONNAKATO AND SONDELA (JABULA).

RFQ 10021074: INSTALL BARRIER LINES

RFQ 10020715: AXIAL PUMP

ADDENDUM OF PRICING SCHEDULE FOR RFQ 10020748

RFQ 10020748: A PROPOSAL PROVISIONING OF CROWD MANAGEMENT AND RIOT CONTROL SECURITY SERVICES FOR MAGALIES WATER ON VARIOUS FACILITIES LOCATED IN THE NORTH WEST AND GAUTENG PROVINCES

RFQ 10018649: ACCESS CONTROL SYSTEM DESIGN AND IMPLEMENTATION FOR KLIPDRIFT WATER TREATMENT PLANT

RFQ 10020834: TERMS OF REFERENCE FOR THE APPOINTMENT OF A SERVICE PROVIDER TO PERFORM RECORDS CLEAN-UP FOR FAR-WEST DOCUMENTS AT MMABATHO REGIONAL OFFICE

RFQ 10020548: MHI RISK ASSESSMENT

RFQ 10019747: SUPPLY PROCESS LAB INSTRUMENTS

RFQ 10019545: HACH 1413µS/CM @25 ºC

RFQ 10019547: CALIBRATION: CONDUCTIVITY METER

RFQ 10020619: PROVIDE MEDICAL SURVEILLANCE SERVICES AT FAR WEST FOR 3 YEARS

RFQ 10019439: PUDIMOE: REPAIR PUMPS MOTORS & COMPRESSOR

RFQ 10017065: REPAIR BTU & SOLKOR RELAYS CIRCUIT

RFQ 10017804: REPAIR PLANT 3 PLC CHEM

RFQ 10019660: REPAIR TUSSENCOMST VSD

RFQ 10019659: STRIP AND QUOTE 3 X WEG VSD FOR PUMP 3

RFQ 10019661: SUPPLY PLC SLOTTED POWER SUPPLY

RFQ 10019635: SUPPLY, INSTALL AND COMMISION SAFSPEC AUTO LUBRICATORS

RFQ 10020509: ICT EQUIPMENT & CARD PRINTING MACHINE

RFQ 10020132: APPOINTMENT OF A CONTRACTOR FOR DRILLING AND EQUIPPING A BOREHOLE AT MORETELE FIRE STATION, IN MAKAPANSTAD.

RFQ 10020446: DIVE-IN SEAL & REPAIR BOSPOORT RESERVOIR

RFQ 10021047: PSP FOR THE FIRE SUPPRESSION PROJECT

RFQ 10020954: Professional Service Provider to carry out a Comprehensive Process Audit

RFQ 10020837: Conduct DYE test of Clear Water Tanks

RFQ 10021135: SECURITY MEASURES – BLOEMHOF WWTP

RFQ 10020915: HDPE Cutting Exact Pipe Cut 460 & training

RFQ 10019269: SERVICE 5 GENERATORS AT BRUSSELS PUMP SET

RFQ 10021075: Install barrier lines

RFQ 10021000 : Appointment of a Contractor for Drilling and Equipping of boreholes in Moretele Local Municipality at Swartdam and Mmoti villages

RFQ 10021002 : Appointment of a Contractor for the Ground Water Augmentation Projects. Which entail Drilling and Equipping of boreholes in Rustenburg Local Municipality at Seraleng (Nkandla), Monnakato and Sondela (Jabula).

RFQ 10021074 : Install barrier lines

RFQ 10020715 : Axial Pump

Addendum of Pricing Schedule for RFQ 10020748

RFQ 10020748: A PROPOSAL PROVISIONING OF CROWD MANAGEMENT AND RIOT CONTROL SECURITY SERVICES FOR MAGALIES WATER ON VARIOUS FACILITIES LOCATED IN THE NORTH WEST AND GAUTENG PROVINCES

RFQ 10018649: ACCESS CONTROL SYSTEM DESIGN AND IMPLEMENTATION FOR KLIPDRIFT WATER TREATMENT PLANT

RFQ 10020834: TERMS OF REFERENCE FOR THE APPOINTMENT OF A SERVICE PROVIDER TO PERFORM RECORDS CLEAN-UP FOR FAR-WEST DOCUMENTS AT MMABATHO REGIONAL OFFICE

RFQ 10020548: MHI Risk Assessment

RFQ 10019747: Supply process lab instruments

RFQ 10019545: HACH 1413µs/cm @25 ºC

RFQ 10019547: Calibration: Conductivity Meter

RFQ 10020619: Provide medical surveillance services at Far West for 3 years

RFQ 10019439: Pudimoe: Repair pumps motors & compressor

RFQ 10017065: Repair BTU & Solkor relays circuit

RFQ 10017804: Repair plant 3 PLC Chem

RFQ 10019660: Repair Tussencomst VSD

RFQ 10019659: Strip and quote 3 x WEG VSD for pump 3

RFQ 10019661: Supply PLC Slotted power Supply

RFQ 10019635: Supply, install and commision Safspec Auto lubricators

RFQ 10020509: ICT Equipment & Card Printing Machine

RFQ 10020132: Appointment of a Contractor for Drilling and Equipping a borehole at Moretele Fire Station, in Makapanstad.

RFQ 10020446: Dive-in Seal & Repair Bospoort Reservoir

RFQ 10019637: Collect used oil from Klipdrift for recycling / disposal

RFQ 10019118: Supply PLC hardware for Supernatant

RFQ 10019118: Reservoir solar panel

RFQ 10019720: DAFF 2 SOUTH PLC REPLACEMENT

RFQ 10019592: SERVICE PROVIDER TO CONDUCT RECORDS CLEAN UP AND ARCHIVING AT HARTSWATER

RFQ 10019714: SUPPLY AND INSTALL FENCE AT BARRICK